Isil Cekic-Nagas1, Gulfem Ergun.
Abstract
OBJECTIVE: The aim of this study was to compare the polimerization ability of three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) and their exposure modes (high-intensity and soft-start) by determination of microhardness, water sorption and solubility, and diametral tensile strength of 5 dual-curing resin cements.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21710093 PMCID: PMC4223794 DOI: 10.1590/s1678-77572011005000017
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Test materials and their composition according to the manufacturers
|
|
|
|
|
|---|---|---|---|
| Catalyst: Bis-GMA, TEGDMA, glass filler (67% wt) | |||
| Bifix-QM | Bis-GMA, benzoylperoxide, amines, barium-aluminiumboro-silicate glass (71-73% wt) | 640422 | Voco GmbH, Cuxhaven, Germany |
| Nexus | SP-345, EBPADM, Fumed silica, UDMA, TEGDMA, Silane, SrSiF6, BPO, BisGMA, UV-9, ZnSiF6, BHT (68% wt) | 449569 | Kerr Co., Orange, CA |
| Liquid: methacrylated phosphoric ester, dimethacrylate, acetate, stabilizer and initiator (72% wt) | |||
| Paste B: barium, boron, silicium glass and NaF(73% wt.) | Paste B: 00052A |
Information provided by manufacturers.
Bis-GMA: Bis-phenol-A diglycidylmethacrylate; TEGDMA: Triethyleneglycol dimethacrylate; UDMA: Urethane dimetacrylate; SP-345: barium aluminoborosilicate; EBPADM: ethoxylated Bis-phenol-A-dimethacrylate; BPO: benzoyl peroxide; BHT: Butylated hydroxy toluene; HDDMA: Hexanediol dimethacrylate; SrSiF6: strontium hexafluorsilicate; UV-9: 2-hydroxy-4-methoxybenzophene; ZnSiF6: zinc hexafluorosilicate; BHT: 2,6-di-tert-butyl-4-methylphenol; BPEDMA: bisphenol-A polyethoxydimethacrylate; MDP: 10-methacryloyloxy decyl dihydrogenphosphate; DMA: aliphatic dimethacrlyate; NaF: sodium fluoride.
Figure 2Schematic illustration of sample preparation and the experimental design
Light-curing units and modes
|
|
|
|
|
|
|---|---|---|---|---|
| High-power Mode | Unit constantly generates the full polymerizing energy (20 s) | |||
| Ramp-curing Mode | Light exposure time 6 s total, intensity as follows: start 2 s at 50%, 2 s at 50%, 2 s at 100% | |||
| Exponential Mode | Provides light increasing to full intensity over the course of 5 s (20 s) |
QTH=Quartz tungsten halogen - PAC=plasma arc - LED=light-emitting diode
Median values and (25th-75th) percentiles for diametral tensile strength (MPa) of the resin cements
|
|
|
| |
|---|---|---|---|
|
|
| ||
| Duolink | QTH | 58.26 (55.08-59.71) | 61.26 (54.4-65.26) |
| LED | 51.80 (50.07-57.76) | 63.86 (52.40-68.44) | |
| PAC | 57.64 (50.06-62.29) | 43.58 (38.71-46.16) | |
| Bifix-QM | QTH | 45.36 (37.19-50.93) | 51.21 (44.21-57.59) |
| LED | 56.07 (51.57-63.2) | 55.86 (46.18-61.33) | |
| PAC | 46.94 (44.45-51.39) | 50.74 (46.9-58.72) | |
| Nexus | QTH | 54.57 (44.96-58.09) | 54.53 (48.66-58.06) |
| LED | 57.41 (44.99-61.02) | 63.82 (54.39-66.83) | |
| PAC | 49.65 (42.63-55.33) | 31.17 (26.92-36.14) | |
| RelyX Unicem | QTH | 41.06 (38.84-45.28) | 32.87 (28.86-34.78) |
| LED | 43.57 (38.37-47.82) | 35.57 (32.89-38.05) | |
| PAC | 34.84 (32.74-42.48) | 27.19 (24-30.24) | |
| Panavia F | QTH | 36.23 (34.19-39.31) | 34.01 (30.53-37.1) |
| LED | 44.78 (41.72-46.15) | 39.06 (34.65-41.94) | |
| PAC | 24.28 (20.20-29.82) | 27.55 (25.17-29.36) | |
LCU=light curing unit. - QTH=quartz tungsten halogen - LED=light-emitting diode - PAC=plasma arc
Median values and (25th-75th) percentiles for Vicker's hardness number (VHN) of the resin cements
|
|
|
| |
|---|---|---|---|
|
|
| ||
| Duolink | QTH | 42.57 (40.28-43.27) | 44.03 (43.18-45.46) |
| LED | 44.63 (43.68-45.66) | 44.13 (42.97-45.57) | |
| PAC | 36.65 (35.73-37.75) | 29.18 (28.23-30.71) | |
| Bifix-QM | QTH | 52.38 (51.32-53.18) | 54.42 (54.24-57.06) |
| LED | 54.50 (53.03-56.63) | 55.25 (52.97-56.63) | |
| PAC | 43.90 (42.51-44.38) | 33.05 (31.85-34.93) | |
| Nexus | QTH | 34.55 (33.32-36.38) | 31.53 (30.77-35.43) |
| LED | 40.63 (39.68-41.13) | 39.43 (37.59-40.84) | |
| PAC | 28.35 (27.13-29.95) | 20.15 (19.03-22.28) | |
| RelyX Unicem | QTH | 47.92 (47.32-49.98) | 52.60 (50.82-53.48) |
| LED | 52.17 (51.16-53.83) | 50.42 (48.88-51.87) | |
| PAC | 37.90 (37.16-38.52) | 21.15 (19.28-23.07) | |
| Panavia F | QTH | 32.13 (31.84-34.63) | 31.25 (29.58-33.57) |
| LED | 24.92 (24.13-27.63) | 27.57 (25.65-28.91) | |
| PAC | 15.65 (15.2-18.05) | 9.76 (8.81-11.02) | |
LCU=light curing unit. - QTH=quartz tungsten halogen - LED=light-emitting diode - PAC=plasma arc
Median values and (25th-75th) percentiles for solubility (μg/mm3) of the resin cements tested after 24 h and 7 days
|
|
| ||||
|---|---|---|---|---|---|
|
| |||||
|
|
| ||||
|
|
|
|
|
| |
|
|
| 5.09 (5.09-7.77) | 9.14 (5.73-10.19) | 1.27 (0.64-2.34) | 2.26 (1.40-2.99) |
|
| 5.09 (5.09-7.01) | 2.73 (2.28-2.96) | 1.95 (1.78-2.47) | 2.55 (1.27-4.46) | |
|
| 10.47 (9.71-11.99) | 10.19 (6.37-10.19) | 2.33 (1.54-2.80) | 4.08 (1.40-7.01) | |
|
|
| 9.91 (8.39-10.19) | 5.1 (5.1-5.1) | 7.88 (6.30-8.53) | 1.66 (1.15-2.43) |
|
| 5.1 (5.1-5.91) | 5.1 (5.1-5.69) | 2.85 (2.55-3.84) | 4.33 (1.27-4.97) | |
|
| 7.64 (5.1-10.19) | 10.19 (8.88-10.19) | 5.87 (5.22-8.09) | 11.47 (10.19-12.93) | |
|
|
| 13.32 (10.67-14.3) | 10.19 (10.19-14.65) | 9.91 (8.62-10.47) | 8.66 (4.97-9.17) |
|
| 5.86 (5.1-9.55) | 10.19 (5.1-10.67) | 1.51 (1.26-2.01) | 8.13 (5.67-9.21) | |
|
| 18.59 (15.75-20.38) | 25.47 (23.75-26.31) | 17.99 (14.39-20.25) | 63.69 (59.76-70.96) | |
|
|
| 27.47 (25.48-30.38) | 35.67 (35.67-40.29) | 23.65 (21.78-28.30) | 32.33 (28.28-35.59) |
|
| 20.38 (15.29-20.86) | 17.95 (15.29-20.38) | 10,96 (8.74-13.04) | 10.5 (9.17-12.98) | |
|
| 43.07 (30.57-45.86) | 64 (61.61-67.83) | 39.03 (35.8-46.21) | 79.59 (69.38-87.91) | |
|
|
| 33.12 (31.84-34.63) | 31.25 (29.58-33.57) | 44.78 (43.26-47.64) | 53.05 (48.49) |
|
| 29.55 (24.20-40.25) | 20.64 (19.11-28.66) | 32.22 (30.19-35.33) | 31.81 (29.01-34.03) | |
|
| 31.79 (21.91-36.93) | 77.01 (72.3-85.75) | 73.93 (73.93-76.57) | 152.14 (127.52-158.56) | |
LCU=light curing unit. - QTH=quartz tungsten halogen - LED=light-emitting diode - PAC=plasma arc
The values written in italics are higher than the required values reported in ADA Specification No. 27 (7.5 μg/mm3)
Median values and (25th-75th) percentiles for sorption (μg/mm3) of the resin cements tested after 24 h and 7 days
|
|
| ||||
|---|---|---|---|---|---|
|
| |||||
|
|
| ||||
|
|
|
|
|
| |
|
|
| 10.61 (8.92-12.61) | 10.19 (10.19-10.19) | 7.13 (6.75-7.64) | 13.04 (10.23-15.54) |
|
| 10.19 (6.37-10.19) | 10.45 (10.19-10.7) | 9.68 (8.79-10.57) | 20.89 (15.8-21.91) | |
|
| 10.19 (10.19-10.19) | 10.19 (10.19-15.29) | 11.46 (7.26-15.8) | 10.70 (9.81-14.01) | |
|
|
| 5.10 (5.1-6.27) | 5.10 (5.1-10.19) | 6.15 (5.1-7.53) | 4.59 (4.08-6.5) |
|
| 6.96 (5.1-7.51) | 10.19 (10.19-10.19) | 6.62 (5.22-8.97) | 7.13 (5.6-8.03) | |
|
| 5.10 (5.1-6.27) | 7.64 (5.1-10.19) | 6.88 (6.62-7.13) | 9.17 (7.77-10.06) | |
|
|
| 10.19 (10.19-14.01) | 7.64 (5.1-10.19) | 9.17 (8.79-10.38) | 8.15 (7.64-8.66) |
|
| 10.19 (5.1-10.19) | 5.10 (5.1-10.19) | 8.41 (5.1-9.68) | 8.92 (7.26-9.55) | |
|
| 10.75 (10.19-14.97) | 24.01 (16.56-25.65) | 11.97 (11.21-17.58) | 16.31 (14.27-17.70) | |
|
|
| 20.38 (16.56-25.48) | 30.57 (30.57-34.4) | 35.16 (33.63-38.6) | 26.24 (22.04-30.96) |
|
| 17.44 (15.29-20.38) | 17.83 (15.29-20.38) | 26.75 (24.97-28.41) | 16.56 (15.29-19.24) | |
|
| 30.57 (25.48-34.4) | 50.96 (45.86-59.87) | 36.18 (31.72-40) | 51.21 (48.15-55.8) | |
|
|
| 36.69 (30.06-44.08) | 36.18 (30.64-36.6) | 36.18 (32.36-45.98) | 53.50 (46.5-56.56) |
|
| 29.55 (24.20-40.25) | 34.14 (30.45-38.47) | 32.22 (30.19-35.33) | 40.25 (35.8-44.08) | |
|
| 37.2 (35.10-38.06) | 64.33 (57.32-71.34) | 73.93 (73.93-76.57) | 106.24 (97.83-108.54) | |
LCU=light curing unit. - QTH=quartz tungsten halogen - LED=light-emitting diode - PAC=plasma arc
The values written in italics higher than the required values reported in ADA Specification No.27 (40 μg/mm3)