Effects of curing protocol and storage time on the micro-hardness of resin cements used to lute fiber-reinforced resin posts.

Marcelo Barbosa Ramos1, Thiago Amadei Pegoraro, Luiz Fernando Pegoraro, Ricardo Marins Carvalho.   

Abstract

OBJECTIVES: To determine the micro-hardness profile of two dual cure resin cements (RelyX-U100, 3M-eSPe and Panavia F 2.0, Kuraray) used for cementing fiberre inforced resin posts (Fibrekor-Jeneric Pentron) under three different curing protocols and two water storage times.
MATERIAL AND METHODS: Sixty 16 mm long bovine incisor roots were endodontically treated and prepared for cementation of the Fibrekor posts. The cements were mixed as instructed, dispensed in the canal, the posts were seated and the curing performed as follows: (a) no light activation; (b) light-activation immediately after seating the post, and; (c) light-activation delayed 5 minutes after seating the post. The teeth were stored in water and retrieved for analysis after 7 days and 3 months. The roots were longitudinally sectioned and the microhardness was determined at the cervical, middle and apical regions along the cement line. The data was analyzed by the three-way ANOVA test (curing mode, storage time and thirds) for each cement. The Tukey test was used for the post-hoc analysis.
RESULTS: Light-activation resulted in a significant increase in the microhardness. This was more evident for the cervical region and for the Panavia cement. Storage in water for 3 months caused a reduction of the micro-hardness for both cements. The U100 cement showed less variation in the micro-hardness regardless of the curing protocol and storage time.
CONCLUSIONS: The micro-hardness of the cements was affected by the curing and storage variables and were material-dependent.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23138743      PMCID: PMC3881793          DOI: 10.1590/s1678-77572012000500011

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

Adhesive cementation of intra-radicular posts is a highly sensitive procedure[10] subjected to technical difficulties that begin during the creation of the post space and involve several operative steps up to the final polymerization of the cement[26]. The advantages are mostly due to their low solubility, superior mechanical and adhesive properties[30]. However, intra-radicular adhesive cementation still presents a significant challenge to clinicians due to the technical variables involved and little knowledge about the clinical predictability of these materials in the long term. Furthermore, resin cements undergo polymerization shrinkage that results in de-bonding tensions and gap formations along the canal walls[9]. Ultimately, light-activation does not reach beyond the cervical cuff and curing remains questionable along the root towards the apice[19,21]. To compensate this limitation, dual-cure resin cements have been developed with the hope that a chemical cure would provide maximum and uniform curing where light cannot reach. This, however, does not seem to be the case with all cements, as some are highly dependent on light energy to achieve adequate polymerization[3,9,27]. Dual polymerization, the combination of light and chemical polymerization, provides a better conversion of monomers. This is important because inadequate polymerization is usually associated with the poor mechanical and biological properties of the resin cements[13]. Immediate light activation is recommended to set the cement, thus allowing the professional to perform subsequent clinical procedures without the need to wait for the chemical set to take place. However, it has been reported that immediate light activation stiffens the polymer chains and prevents the continuation of the chemical polymerization, thus causing an overall reduction in the degree of conversion with consequences to the material properties[24]. The need for immediate light activation of dual cure cements has therefore been questioned as it could compromise chemical polymerization[24,28]. Some authors have suggested that the light activation should be delayed, so that chemical polymerization could progress further without being hindered by the stiffened light-cured chain. This could improve the overall degree of conversion and properties[23]. Ideally, resin cements should achieve their maximum cross-linking and degree of conversion to be able to withstand the intraoral challenges. A less than optimal cure has been related to increased water sorption[8,30], which in turn causes a reduction of their mechanical properties, dissolving and leaching of some of the components, such as unreacted to degradation and erosion of the resin cement[16]. The micro-hardness test has been successfully used to evaluate the quality of the polymerization and the effects of water sorption on the resin materials[4,11,15,26]. This study evaluated the changes in the micro-hardness of two resin cements used to lute fiber-reinforced resin posts with modified, experimental curing protocols, along the cervical, middle and apical thirds. The micro-hardness measurements were taken after 7 days and 3 months of water storage. The null hypotheses tested were that: 1) the curing protocol would not affect the micro-hardness; 2) the micro-hardness would not vary along the root thirds, and; 3) water storage would not affect the micro-hardness.

MATERIAL AND METHODS

Sixty bovine incisors were transversally sectioned to remove the crowns and result in roots with 16 mm in length. The canals were instrumented with a#25 K-file (Kerr Dental Manufacturing Co., Orange, CA, USA). The root canals were irrigated with 10 mL of 1.0% NaOCl between each instrument change. The final irrigation was with 10 mL of 17% EDTA for 60 sec, followed by 10 mL of NaOCl irrigation. The root canals were dried using paper points and obturated with gutta-percha (Endo Points, Paraíba do Sul, RJ, Brazil). A size 40 gutta-percha cone was used as the master cone. The gutta-percha cones were coated with a calcium hydroxide-based cement (Sealer 26/ Dentsply, Rio de Janeiro, RJ, Brazil) before insertion into the canal by the lateral condensation technique and stored in water at 37ºC until the preparation for post cementation (Figures 1A-C). The post space was created with a 1.0 mm diameter/13 mm long bur (Fibrekor bur, Pentron Clinical Technologies, LLC., Wallingford, CT, USA), followed by a 1.5 mm diameter bur (Fibrekor drill, Pentron Clinical Technologies, LLC., Wallingford, CT, USA), up to the length of 12 mm in order to standardize the cement line thickness at approximately 0.25 mm around the post. The fiberglass posts (Fibrekor, Pentron Clinical Technologies, LLC, Wallingford, CT, USA) were previously cleaned with 75% ethanol. Before the cementation, the canals were flushed with deionized water and dried with absorbent paper points. The cementation procedures were performed with two different dual-cure resin cements, Panavia F 2.0 (Kuraray Medical Inc. Kurashiki, Okayama, Japan) or RelyX U100 (3M ESPE, St. Paul, Minnesota, USA) (Figures 1D-F and Figure 2). The mixed cements were applied on the post, which were then inserted into the canal. The excess cement was removed with a micro-brush.
Figure 1

Schematic flow chart of the experimental steps: a: sectioning the bovine roots to the length of 16 mm; b,c: endodontic treatment; d: post space preparation with 1 mm-diameter bur to the length of 13 mm; and e: enlargement of post space with1.5 mm-diameter bur to the length of 12 mm; f: post cemented using either one of the cements; g: specimens stored in water for either 7 days or 3 months; h: root sectioning to expose the cement line; i: surface polishing for hardness measurements; j: ultrasound cleaning of specimens; k: microhardness indentations placed along the cement line

Figure 2

Resin cements used in the study

Cement*Adhesive System*ManufacturerLot
PANAVIA F 2.0:ED PRIMER A & B:Kuraray Inc., Japan51198
Paste A: Silanized silica, colloidal silica, bisphenol A polyethoxy dimethacrylate, 10-methacryloyloxydecil dihydrogen phosphate, hydrophobic and hydrophilic dimethacrylate, benzoyl peroxide and camphorquinone; Paste B: Silanized barium glass, silanized titanium oxide, sodium fluoride, colloidal silica, bisphenol A polyethoxy dimethacrylate, hydrophobic dimethacrylate, hydrophilic dimethacrylate, n,n'-diethanol-p-toluidine, sodium sulphinate 2,4,6- triisopropyl benzene. Oxiguard: polyethylene glycol, glycerin, sodium benzene sulphinate, n,n'-diethanol p-toluidine. ED Primer A: 2- hydroxyethyl methacrylate, 10-methacryloyloxydecil dihydrogen phosphate, N-metha-cryloyl-5-aminosalicylic acid, n,n'-diethanol -p-toluidine and water; ED Primer B: N-metha-cryloyl- 5-aminosalicylic acid, sodium benzene sulphinate, n,n'-diethanol p-toluidine and water.
RELYX U100:Not required.3M ESPE, USA287269
Base paste: glass fiber, phosphoric acid esters methacrylate, triethyleneglycol dimethacrylate, silica treated with silane and sodium persulphate. Catalyst paste: glass fiber, substitute dimethacrylate silica treated with silane, p-toluenesulphate sodium and calcium hydroxide.

Source: manufacturers' website

Schematic flow chart of the experimental steps: a: sectioning the bovine roots to the length of 16 mm; b,c: endodontic treatment; d: post space preparation with 1 mm-diameter bur to the length of 13 mm; and e: enlargement of post space with1.5 mm-diameter bur to the length of 12 mm; f: post cemented using either one of the cements; g: specimens stored in water for either 7 days or 3 months; h: root sectioning to expose the cement line; i: surface polishing for hardness measurements; j: ultrasound cleaning of specimens; k: microhardness indentations placed along the cement line Resin cements used in the study Source: manufacturers' website For the cementation, the roots were randomly divided into 2 groups of 30 specimens per cement, and then further divided into 3 groups of 10 specimens according to the polymerization modes as follows: Group A (no light activation), Group B (immediate light activation) and Group C (delayed light activation for 5 minutes). The cements were light activated for 20 s (Optilight Plus, 420 mW/cm2, Gnatus Equip. Med. Odont., Ribeirão Preto, SP, Brazil) with the tip of the lamp placed at the post. After completing the cementation, the specimens were stored in dark vials containing deionized water at 37ºC (Figure 1G). Five specimens from each group were retrieved after 7 days for testing (subgroup 1). The remaining specimens were kept under storage for 3 months (subgroup 2) and tested after that period. The water in the vials was replaced every 15 days during the storage period. Details of the cementation procedures are given in Figure 3.
Figure 3

Cementation procedures

CementAdhesiveProcedures
Panavia F 2.0ED primer A and BAdhesive application (1 drop ED primer A + 1 drop ED primer B) for 30 s. Excess removed with absorbent paper tips, air jet for 10 s. Paste A+ B manipulated for 20 s, applied to post, and post placed in the canal. Excess cement removed with microbrush. Group A1: Oxiguard® applied to exposed cement margins and removed after 3 min with water spray; Group B1: Oxiguard® applied as in the group A1 followed by immediate light activation for 20 s; Group C1: 20 s light activation 5 minutes after removal of Oxiguard.
U100Not requiredThe pastes were dispensed on a mixing pad from the Clicker and hand mixed for 30 s. The cement was applied directly to the post that was inserted in the canal, excess cement removed with microbrush. Group A1: No light activation after excess cement removed; Group B1: Excess cement removed followed by immediate light activation for 20 s ; Group C1: Delayed light activation for 5 minutes after excess cement was removed.
Cementation procedures

Root sectioning and micro-hardness measurements

After retrieving from storage, the roots were longitudinally sectioned with a diamond disk (Wafering Diamond Blade - Extec, USA) in a serial cutting machine (Isomet 2000 Precision Saw - Buehler, USA). The cut was made tangential to the post so that the cement line could later be exposed by sequential polishing. A second parallel cut was placed on the opposite external surface of the root to permit the seating of the specimen in the micro-hardness tester stage (Figure 1H). The exposed post surface was sequentially polished with 600-grit SiC abrasive paper for 3 minutes at a low speed and 1200-grit SiC abrasive paper for 5 minutes at a high speed, followed by felt paper and diamond paste for 5 minutes in a high speed under constant irrigation. Between each polishing step, the specimens were rinsed with deionized water for 30 seconds and ultrasonicated in deionized water for 2 minutes (Figure 1I-J). The hardness tests were performed (Shimadzu Microdurometer Model HMV-2.000, Shimadzu Corporation, Japan) with a Knoop indenter under a static load of 50 grams for 10 seconds that was defined in the pilot test and based on other study[26] (Figure 1K). Indentations were placed in the middle of the cement line, 1 mm apart from the cervical to apical third. The micro-hardness was calculated as the average value for each third. The first four indentations were assigned as the cervical third, the following four indentations were assigned as the middle third and the last four indentations were assigned as the apical third. The hardness was calculated and expressed as a Knoop hardness number (KHN) according to the following formula: HK=P/A=P/Cp. L2 Where "P" is the load (kgf); "A" is the impression area (mm2); "L" is the impression length (mm); Cp is the indenter correction factor. The measurements were averaged by thirds and the results (KHN) were calculated for the thirds and groups.

Statistical analysis

The data was analyzed by separate three-way ANOVA testing applied to each cement and the individual differences were investigated by the Tukey's post-hoc test. The analysis investigated the influence of the curing mode, root location (thirds) and storage time. The significance level was set for all analysis at α=0.05.

RESULTS

For the Panavia (Table 1), the hardness was affected by the curing protocol (p=0.001; F=218.7), thirds (p=0.0001) and storage (p=0.0001). Significant interactions were also found between the storage vs. curing protocol (p=0.013), storage vs. thirds (p=0.0001), and the curing protocol vs. thirds (p=0.0001). No significant interaction were found between the storage, curing protocol and thirds (p=0.093). When no light activation was provided (Group A), the hardness was uniform along the root (p>.05) and significantly lower between the cervical and apical third (p<.05). When light was provided (Groups B and C), the hardness was significantly higher at the cervical cuff (p<.05) and decreased significantly towards the apical third (p<.05) except in group C1 that did not show a difference between the middle and apical thirds. At the apical third, delaying light activation for 5 min (C) resulted in significantly higher hardness than both immediate light activation (B) and chemical activation (A) (p<.05).
Table 1

Knoop hardness number (KHN) standard deviation for Panavia 2F cement according to conditions tested

GROUPS/ CURING PROTOCOLSTORAGE CERVICALMIDDLE APICAL
A1/ NO LIGHT ACTIVATION7 days41.2 (3.38)Aa38.1 (1.74)ABa35.6 (1.73)Ba
A2/ NO LIGHT ACTIVATION3 months37.1 (1.38)Ba35.0 (0.74)ABa34.1 (2.37)Aa
B1/ LIGHT ACTIVATION IMMEDIATELY7 days75.2 (4.84)Ab *60.3 (6.76)Bb48,9 (3,33)Cb
B2/ LIGHT ACTIVATION IMMEDIATELY3 months63.0 (2.17)Ab55.9 (2.10)Bb48.5 (1.62)Cb
C1/ LIGHT ACTIVATION DELAYED7 days70.2 (1.93)Bb *61.0 (4.48)Ab *56.4 (7.51)Ac *
C2/ LIGHT ACTIVATION DELAYED3 months56.9 (1.21)Bb51.2 (1.81)Ab48.2 (3.00)Ab

indicates significant differences between storage periods for the same group (subgroups 1 and 2).

Identical capital letters indicate no significant differences among thirds for the same curing protocol (p>.05).

Identical lower cases indicate no significant differences among curing protocols within each third (p>.05).

Knoop hardness number (KHN) standard deviation for Panavia 2F cement according to conditions tested indicates significant differences between storage periods for the same group (subgroups 1 and 2). Identical capital letters indicate no significant differences among thirds for the same curing protocol (p>.05). Identical lower cases indicate no significant differences among curing protocols within each third (p>.05). Water storage for 3 months caused reductions in the hardness regardless of the thirds and curing modes. When comparing the storage periods, the results were not significant when no light was provided (Group A1 vs. A2, p>.05), but were significant when light was provided at the cervical cuff (Group B1 vs. B2), especially for the delayed activated (Group C1 vs. C2), in which significant reductions were observed in all three thirds (p<.05). For the U100 cement (Table 2) the effects of the curing protocol (p=0.018; F=4.74) and region of the root (p=0.0001; F=60.3) were significant. No significant differences were found between the storage periods (p=0.878; F=0.02). Significant interactions were found for the storage vs. the thirds (p=0.0001; F=21.6). Higher, but not significant hardness was observed when light was provided. This was only evident at the cervical cuff at the 7-day period.
Table 2

Knoop hardness number (KHN) standard deviation for U100 cement according to conditions tested

GROUPS/ CURING PROTOCOLSTORAGE CERVICALMIDDLE APICAL
A1/ NO LIGHT ACTIVATION7 days59.4 (4.32)Aa52.1 (3.00)Ba50.2 (4.13)Ba
A2/ NO LIGHT ACTIVATION3 months52.3 (2.00)Aa52.1 (3.01)Aa51.0 (1.48)Aa
B1/ LIGHT ACTIVATION IMMEDIATELY7 days62.4 (6.83)Aa53.9 (4.74)Ba49.0 (2.20)Ba *
B2/ LIGHT ACTIVATION IMMEDIATELY3 months58.8 (2.34)Ab55.19 (1.42)Ba55,7 (3,17)Ba
C1/ LIGHT ACTIVATION DELAYED7 days62.4 (6.66)Aa53.6 (2.00)Ba51.5 (2.18)Ba
C2/ LIGHT ACTIVATION DELAYED3 months59.0 (2.04)Ab57.0 (2.04)ABa 54.9 (1.05)Ba

indicates significant differences between storage periods for the same group (subgroups 1 and 2).

Identical capital letters indicate no significant differences among thirds for the same curing protocol (p>.05).

Identical lower cases indicate no significant differences among curing protocols within each third (p>.05).

Knoop hardness number (KHN) standard deviation for U100 cement according to conditions tested indicates significant differences between storage periods for the same group (subgroups 1 and 2). Identical capital letters indicate no significant differences among thirds for the same curing protocol (p>.05). Identical lower cases indicate no significant differences among curing protocols within each third (p>.05). Water storage did not cause changes in the hardness for most of the testing conditions, except for the immediate light activation (Group B1 vs B2) at the apical third (p<.05).

DISCUSSION

The results showed that light activation always resulted in higher hardness than no light activation. This was more evident for the Panavia than the U100, regardless of the thirds and storage. These results are in agreement with the literature and suggest that dual cure cements should be light activated in order to maximize their properties[12,30]. Since dual cure cements have two polymerization routes, it is expected that chemical polymerization ensures curing in the regions most distant from the light source[8]. Although these two routes are present in the dual cure cement, chemical polymerization will not activate the photosensitive portion of the cement if the light exposure is insufficient, as may occur in the apical portion of intra-radicular luted posts[24]. Ideally, the two polymerization routes should occur simultaneously and independently. However, a concern has been raised that as light activation promotes rapid stiffening of the polymer chains, the development of the chemical reaction is affected, thus altering the physical properties of the material[8]. The question about whether light activation would harm the chemical reaction of some dual cure cements[24] led some authors to suggest delaying the light activation for a few minutes after mixing and luting[23]. The results of this study did not support this aspect for the two cements evaluated. The significant reduction in the hardness of the Panavia cement in the middle and apical thirds shows the effect of the attenuation of the light intensity as a result of the distance from the light source and transmission through the cement[18,28], which progressively reduces the rate of polymerization. In this study, both cements presented higher hardness when light activation was provided (Groups B and C), and there was no indication that light activation compromised the hardness in any situation investigated. On the contrary, the higher hardness observed for the cervical third suggests that the properties of both cements are positively influenced by light exposure. Storage in water for 3 months caused significant reductions in the hardness in most groups, irrespective of the activation mode and region. This was more evident for the Panavia than for the U100. The effect of water on the polymeric network is described as plasticizing and it promotes the reduction in hardness due to the separation of the polymeric chains by molecules that do not form primary links with them, but only occupy a space between them. Thus, the polymer is not dissolved, but intumesces in contact with the solvent that promotes a greater attraction between the molecules of the solvent and the components of the chains that exceed the forces of attraction between the polymer chains[7]. Consequently, there is an increase in volume of the polymeric network and a potential effect of plasticization resulting from less interaction between the chains[7,16]. The results for the U100 suggest that the hardness was dependent on the contact and reaction of the cement with the dental structures, which occurred inside the canal. The mechanism of self-adhesion to the dental structures occurs due to the presence of phosphorylated methacrylate radicals[1], which are neutralized by the substrate when in contact with the dentin while the material is polymerized. In this material, the water formed during the initial reaction of the phosphorylated methacrylates with the apatite and basic load particles is reused in the reaction with excess acids, which result in the substitution of hydrophilic properties before setting by the hydrophobic properties after setting. This suggests a reduction of sensitivity of the material to humidity, and a consequent reduction of solubility in the oral medium[1]. Therefore, this cement was shown to be less critical in the presence of humidity probably because of being dimensionally stable and because the water produced in the chemical reaction is consumed in other reactions of the cement itself[26]. Although there are several difficulties in reproducing the oral conditions in in vitro studies, especially with regard to humidity, the results of this experiment show the existent obstacles to achieve an adequate degree of conversion in the intra-radicular environment. When hardness tests are used as an indirect measurement of the degree of conversion of composites, it is important to consider the different chemical compositions of the evaluated brands, bearing in mind that these influence the cross-link density formed during polymerization and consequently, the mechanical properties of the material[15]. The attenuation and dispersion of the halogen light resulting from material thickness, distance from the surface and size and amount of load produces a gradual reduction in polymerization[17]. Therefore, the adequate degree of conversion of a luting agent is very important for the longevity of the restoration. Some resin cements, such as the Panavia F 2.0®, are materials that are dependent on the light activation of polymerization to reach adequate properties[5,22,25]. The polymerization potential of dual cure resin cements varies widely among products[26,29] and this variation was also confirmed in this study. The results obtained in the hardness tests are in agreement with the concepts generally accepted in the literature, which is that all dual cure cements should be light activated to reach their maximum properties[6,14,20,30]. Generally, the simplification of steps in the adhesive system and the polymerization reaction of adhesives and resin cements have a direct effect on the adhesive post/dentin substrate interface[2]. The results of this study indicated that the delay of light activation was not an efficient procedure. Isolated cases of improvement or harm were observed, but no trend could be established. Thus, delaying light activation of the cement is not justifiable as a protocol for the dual cure cements evaluated in this study. In general, dual cure cements require light activation to reach their adequate physical and mechanical properties so that the restorations can bear the stresses that are produced at the restoration/cement/tooth interface, especially in the early post-cementation periods. The professional must be aware that these cements do not reach a degree of maximum polymerization in areas distant from the light source. However, it remains unknown how this shortcoming manifests clinically.

CONCLUSIONS

Based on the results obtained, it could be concluded that: 1- The light activation with halogen light promoted a significant increase in the hardness for the Panavia cement; 2- Storage in water for three months reduced the micro-hardness values for most groups, and the U100 cement showed less variation in the results when compared with the Panavia; 3- Most cervical thirds showed the highest hardness for both cements.
  29 in total

1.  Comparison of photo-activation versus chemical or dual-curing of resin-based luting cements regarding flexural strength, modulus and surface hardness.

Authors:  N Hofmann; G Papsthart; B Hugo; B Klaiber
Journal:  J Oral Rehabil       Date:  2001-11       Impact factor: 3.837

2.  Efficacy of a self-curing adhesive-resin cement system on luting glass-fiber posts into root canals: an SEM investigation.

Authors:  M Ferrari; A Vichi; S Grandini; C Goracci
Journal:  Int J Prosthodont       Date:  2001 Nov-Dec       Impact factor: 1.681

3.  Energy dependent polymerization of resin-based composite.

Authors:  Rolf H Halvorson; Robert L Erickson; Carel L Davidson
Journal:  Dent Mater       Date:  2002-09       Impact factor: 5.304

4.  Effect of curing protocol on the polymerization of dual-cured resin cements.

Authors:  Sónia G Pereira; Rogério Fulgêncio; Teresa G Nunes; Manuel Toledano; Raquel Osorio; Ricardo Marins Carvalho
Journal:  Dent Mater       Date:  2010-04-09       Impact factor: 5.304

5.  Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins.

Authors:  J L Ferracane
Journal:  Dent Mater       Date:  1985-02       Impact factor: 5.304

6.  Dual-cure resin cements: in vitro wear and effect of quantity of remaining double bonds, filler volume, and light curing.

Authors:  A Peutzfeldt
Journal:  Acta Odontol Scand       Date:  1995-02       Impact factor: 2.331

7.  The influence of light exposure on polymerization of dual-cure resin cements.

Authors:  F A Rueggeberg; W F Caughman
Journal:  Oper Dent       Date:  1993 Mar-Apr       Impact factor: 2.440

8.  Curing depth of (polyacid-modified) composite resins determined by scraping and a penetrometer.

Authors:  Nikolaos S Koupis; Chris W J Vercruysse; Luc A M Marks; Luc C Martens; Ronald M H Verbeeck
Journal:  Dent Mater       Date:  2004-12       Impact factor: 5.304

9.  Softening of BISGMA-based polymers by ethanol and by organic acids of plaque.

Authors:  E Asmussen
Journal:  Scand J Dent Res       Date:  1984-06

10.  Polymer structure of a light-cured resin composite in relation to distance from the surface.

Authors:  Erik Asmussen; Anne Peutzfeldt
Journal:  Eur J Oral Sci       Date:  2003-06       Impact factor: 2.612

View more
  5 in total

1.  Influence of Curing Mode on the Surface Energy and Sorption/Solubility of Dental Self-Adhesive Resin Cements.

Authors:  Hyun-Jin Kim; Rafat Bagheri; Young Kyung Kim; Jun Sik Son; Tae-Yub Kwon
Journal:  Materials (Basel)       Date:  2017-02-04       Impact factor: 3.623

2.  Effect of Delayed Light-Curing Through a Zirconia Disc on Microhardness and Fracture Toughness of Two Types of Dual-Cure Cement.

Authors:  Pouran Samimi; Sara Kaveh; Maryam Khoroushi
Journal:  J Dent (Tehran)       Date:  2018-11

3.  Influence of inorganic composition and filler particle morphology on the mechanical properties of self-adhesive resin cements.

Authors:  Marina Rodrigues Santi; Rodrigo Barros Esteves Lins; Beatriz Ometto Sahadi; Giovanna Corrêa Denucci; Gabriela Soffner; Luís Roberto Marcondes Martins
Journal:  Restor Dent Endod       Date:  2022-07-14

4.  Push-out bond strengths of fiber-reinforced composite posts with various resin cements according to the root level.

Authors:  Hoon-Sang Chang; Young-Sin Noh; Yoon Lee; Kyung-San Min; Ji-Myung Bae
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

5.  Influence of light-exposure methods and depths of cavity on the microhardness of dual-cured core build-up resin composites.

Authors:  Keiichi Yoshida; Xiangfeng Meng
Journal:  J Appl Oral Sci       Date:  2014 Jan-Feb       Impact factor: 2.698

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.