Literature DB >> 17432397

Ceramic-dentin bonding: effect of adhesive systems and light-curing units.

Isil Cekic1, Gulfem Ergun, Lippo V J Lassila, Pekka K Vallittu.   

Abstract

PURPOSE: To investigate the effect of different light-curing units and adhesive systems on the bonding of leucite ceramic to dentin.
MATERIALS AND METHODS: Flat dentin surfaces were ground occlusally on human molars (n = 60). Hot-pressed ceramic blocks of IPS Empress (Ivoclar-Vivadent) were fabricated, air-particle abraded, and cleaned in distilled water. Following acid etching and silane treatment of ceramic, bonding procedures were performed. The teeth were divided into two groups according to the type of the adhesive system: (1) total-etch: etchant (Etch 37) and adhesive (One Step Plus); (2) self-etching: self-priming etchant (Tyrian SPE) and adhesiveOne Step Plus) (n = 30). Ceramic blocks were bonded to the dentin surfaces with dual-polymerizing resin luting cement (Duolink). For polymerization, the QTH (Blue Swan Digital, Dentanet) was used in soft-up and high-power mode, the LED (Elipar Freelight 2, 3M Espe) in exponential and standard mode, and the PAC (PlasmaStar, SP-2000, Monitex) in normal and ramp-curing mode (n = 5). Following storage in distilled water for 24 h, the samples were thermocycled for 6000 cycles. The bonded specimens were serially sectioned and trimmed to hourglass shapes with approximately 1.6 +/- 0.16 mm2 cross-sectional areas, then tested with the microtensile tester at a rate of 1 mm/min. Fracture surfaces (were analyzed with SEM. The data were analyzed with three-way analysis of variance (ANOVA).
RESULTS: ANOVA revealed that adhesive systems (p < 0.001) and light-curing units (p = 0.015) had a significant effect on bond strength values. Bond strength means (+/- SD) in MPa were as follows: total-etch system: QTH/soft-up mode = 16.2 (5.4); QTH/high power mode = 15 (5.4); LED/standard mode = 12.1 (3.3); LED/exponential mode = 15 (5); PAC/normal mode = 19.3 (7); PAC/ramp-curing mode = 19.6 (7.4). Self-etching system: QTH/soft-up mode = 9.9 (2.1); QTH/high-power mode = 12.5 (4.3); LED/standard mode = 8.6 (2); LED/exponential mode = 13 (3.8); PAC/normal mode = 13.1 (3.9); PAC/ramp-curing mode = 8.9 (2.2).
CONCLUSION: Results indicated that the conventional total-etch system provided more reliable bonding compared to the self-etching system. The PAC light-curing unit together with the total-etch adhesive system showed the highest mean micro-TBS values with either normal mode or ramp-curing mode.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17432397

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  6 in total

1.  The effect of irradiation distance on microhardness of resin composites cured with different light curing units.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun
Journal:  Eur J Dent       Date:  2010-10

2.  Comparison of light transmittance in different thicknesses of zirconia under various light curing units.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

Review 3.  Correlation between clinical performance and degree of conversion of resin cements: a literature review.

Authors:  Grace De Souza; Roberto Ruggiero Braga; Paulo Francisco Cesar; Guilherme Carpena Lopes
Journal:  J Appl Oral Sci       Date:  2015 Jul-Aug       Impact factor: 2.698

4.  Effect of different light curing methods on mechanical and physical properties of resin-cements polymerized through ceramic discs.

Authors:  Isil Cekic-Nagas; Gulfem Ergun
Journal:  J Appl Oral Sci       Date:  2011-07-01       Impact factor: 2.698

5.  Comparison of temperature change among different adhesive resin cement during polymerization process.

Authors:  Murat Alkurt; Zeynep Yesil Duymus; Mustafa Gundogdu; Muhammet Karadas
Journal:  J Indian Prosthodont Soc       Date:  2017 Apr-Jun

6.  Survival of Prosthodontic Restorations Luted with Resin-Based versus Composite-Based Cements: Retrospective Cohort Study.

Authors:  Ján Staněk; Abanoub Riad; Adam Le; Matěj Bernát; Milad Hammal; Basel Azar
Journal:  Materials (Basel)       Date:  2022-01-02       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.