Literature DB >> 16625042

Calculation of stopping power ratios for carbon ion dosimetry.

Oksana Geithner1, P Andreo, N Sobolevsky, G Hartmann, O Jäkel.   

Abstract

Water-to-air stopping power ratio calculations for the ionization chamber dosimetry of clinical carbon ion beams with initial energies from 50 to 450 MeV/u have been performed using the Monte Carlo technique. To simulate the transport of a particle in water the computer code SHIELD-HIT v2 was used, which is a newly developed version where substantial modifications were implemented on its predecessor SHIELD-HIT v1 (Gudowska et al 2004 Phys. Med. Biol. 49 1933-58). The code was completely rewritten replacing formerly used single precision variables with double precision variables. The lowest particle transport specific energy was decreased from 1 MeV/u down to 10 keV/u by modifying the Bethe-Bloch formula, thus widening its range for medical dosimetry applications. In addition, the code includes optionally MSTAR and ICRU-73 stopping power data. The fragmentation model was verified and its parameters were also adjusted. The present code version shows excellent agreement with experimental data. It has been used to compute the physical quantities needed for the calculation of stopping power ratios, s(water,air), of carbon beams. Compared with the recommended constant value given in the IAEA Code of Practice, the differences found in the present investigations varied between 0.5% and 1% at the plateau region, respectively for 400 MeV/u and 50 MeV/u beams, and up to 2.3% in the vicinity of the Bragg peak for 50 MeV/u.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16625042     DOI: 10.1088/0031-9155/51/9/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  A beam-specific planning target volume (PTV) design for proton therapy to account for setup and range uncertainties.

Authors:  Peter C Park; X Ronald Zhu; Andrew K Lee; Narayan Sahoo; Adam D Melancon; Lifei Zhang; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-06-22       Impact factor: 7.038

2.  Traceable dosimetry for MeV ion beams.

Authors:  G Garty; A D Harken; D J Brenner
Journal:  J Instrum       Date:  2022-02-08       Impact factor: 1.121

3.  Induced Radionuclides and Their Activity Concentration in Gel Dosimeters Irradiated by Carbon Ion Beam.

Authors:  Masumitsu Toyohara; Shinichi Minohara; Yohsuke Kusano; Hiroaki Gotoh; Yoichiro Tanaka; Masaru Yuhara; Yu Yamashita; Yoshiaki Shimono
Journal:  Gels       Date:  2022-03-23

4.  Monte Carlo calculation of beam quality correction for solid-state detectors and phantom scatter correction at 137Cs energy.

Authors:  T Palani Selvam; Subhalaxmi Mishra; R S Vishwakarma
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.