Literature DB >> 21697155

Accuracy of linear measurement in the Galileos cone beam computed tomography under simulated clinical conditions.

R Ganguly1, A Ruprecht, S Vincent, J Hellstein, S Timmons, F Qian.   

Abstract

OBJECTIVES: The aim of this study was to determine the geometric accuracy of cone beam CT (CBCT)-based linear measurements of bone height obtained with the Galileos CBCT (Sirona Dental Systems Inc., Bensheim, Hessen, Germany) in the presence of soft tissues.
METHODS: Six embalmed cadaver heads were imaged with the Galileos CBCT unit subsequent to placement of radiopaque fiduciary markers over the buccal and lingual cortical plates. Electronic linear measurements of bone height were obtained using the Sirona software. Physical measurements were obtained with digital calipers at the same location. This distance was compared on all six specimens bilaterally to determine accuracy of the image measurements.
RESULTS: The findings showed no statistically significant difference between the imaging and physical measurements (P > 0.05) as determined by a paired sample t-test. The intraclass correlation was used to measure the intrarater reliability of repeated measures and there was no statistically significant difference between measurements performed at the same location (P > 0.05).
CONCLUSIONS: The Galileos CBCT image-based linear measurement between anatomical structures within the mandible in the presence of soft tissues is sufficiently accurate for clinical use.

Mesh:

Year:  2011        PMID: 21697155      PMCID: PMC3520257          DOI: 10.1259/dmfr/72117593

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  15 in total

1.  Development of a compact computed tomographic apparatus for dental use.

Authors:  Y Arai; E Tammisalo; K Iwai; K Hashimoto; K Shinoda
Journal:  Dentomaxillofac Radiol       Date:  1999-07       Impact factor: 2.419

2.  A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine.

Authors:  Koji Hashimoto; Yoshinori Arai; Kazuo Iwai; Masao Araki; Shoji Kawashima; Masaaki Terakado
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2003-03

3.  Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit.

Authors:  J B Ludlow; L E Davies-Ludlow; S L Brooks
Journal:  Dentomaxillofac Radiol       Date:  2003-07       Impact factor: 2.419

4.  Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom).

Authors:  C A Lascala; J Panella; M M Marques
Journal:  Dentomaxillofac Radiol       Date:  2004-09       Impact factor: 2.419

5.  Accuracy of measurements of mandibular anatomy in cone beam computed tomography images.

Authors:  John B Ludlow; William Stewart Laster; Meit See; L'Tanya J Bailey; H Garland Hershey
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-08-04

6.  Accuracy of linear measurement provided by cone beam computed tomography to assess bone quantity in the posterior maxilla: a human cadaver study.

Authors:  Sophie Veyre-Goulet; Thomas Fortin; Anthony Thierry
Journal:  Clin Implant Dent Relat Res       Date:  2008-04-01       Impact factor: 3.932

Review 7.  Imaging techniques and image interpretation for dental implant treatment.

Authors:  C C Wyatt; M J Pharoah
Journal:  Int J Prosthodont       Date:  1998 Sep-Oct       Impact factor: 1.681

8.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results.

Authors:  P Mozzo; C Procacci; A Tacconi; P T Martini; I A Andreis
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

9.  Radiographic evaluation of mandibular posterior implant sites: correlation between panoramic and tomographic determinations.

Authors:  A Bolin; S Eliasson; M von Beetzen; L Jansson
Journal:  Clin Oral Implants Res       Date:  1996-12       Impact factor: 5.977

10.  Presurgical radiographic assessment for implants.

Authors:  C G Petrikowski; M J Pharoah; A Schmitt
Journal:  J Prosthet Dent       Date:  1989-01       Impact factor: 3.426

View more
  19 in total

1.  Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles.

Authors:  Sima Nikneshan; Shadi Hamidi Aval; Neema Bakhshalian; Shahriyar Shahab; Mahdis Mohammadpour; Soodeh Sarikhani
Journal:  Imaging Sci Dent       Date:  2014-11-25

2.  Comparison of different methods to assess alveolar cleft defects in cone beam CT images.

Authors:  Gabriella Lopes de Rezende Barbosa; Jeyhan S Wood; Luiz A Pimenta; Solange Maria de Almeida; Donald A Tyndall
Journal:  Dentomaxillofac Radiol       Date:  2015-12-09       Impact factor: 2.419

3.  Dimensional accuracy of cone beam CT with varying angulation of the jaw to the X-ray beam.

Authors:  George K Koch; Adam Hamilton; Kelly Wang; Laura Herschdorfer; Kyu Ha Lee; German O Gallucci; Bernard Friedland
Journal:  Dentomaxillofac Radiol       Date:  2018-11-08       Impact factor: 2.419

4.  Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography.

Authors:  Hanadi Sabban; Mina Mahdian; Ajay Dhingra; Alan G Lurie; Aditya Tadinada
Journal:  Imaging Sci Dent       Date:  2015-06-19

5.  The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions.

Authors:  Rumpa Ganguly; Aruna Ramesh; Sarah Pagni
Journal:  Imaging Sci Dent       Date:  2016-06-23

6.  Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study.

Authors:  Verónica García-Sanz; Carlos Bellot-Arcís; Virginia Hernández; Pedro Serrano-Sánchez; Juan Guarinos; Vanessa Paredes-Gallardo
Journal:  Sci Rep       Date:  2017-09-20       Impact factor: 4.379

7.  Influence of Head Position on the CBCT Accuracy in Assessment of the Proximity of the Root Apices to the Inferior Alveolar Canal.

Authors:  Sadaf Adibi; Shoaleh Shahidi; Saeed Nikanjam; Maryam Paknahad; Mohammadali Ranjbar
Journal:  J Dent (Shiraz)       Date:  2017-09

8.  Accuracy of linear measurements of galileos cone beam computed tomography in normal and different head positions.

Authors:  Mahnaz Sheikhi; Sajad Ghorbanizadeh; Mehrdad Abdinian; Hossein Goroohi; Hamid Badrian
Journal:  Int J Dent       Date:  2012-07-16

9.  Alveolar bone thickness around maxillary central incisors of different inclination assessed with cone-beam computed tomography.

Authors:  Yu-Lou Tian; Fang Liu; Hong-Jing Sun; Pin Lv; Yu-Ming Cao; Mo Yu; Yang Yue
Journal:  Korean J Orthod       Date:  2015-09-23       Impact factor: 1.372

10.  A Comparative Evaluation of Mixed Dentition Analysis on Reliability of Cone Beam Computed Tomography Image Compared to Plaster Model.

Authors:  Snigdha Gowd; T Shankar; Samarendra Dash; Nivedita Sahoo; Suravi Chatterjee; Pritam Mohanty
Journal:  J Int Soc Prev Community Dent       Date:  2017-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.