Literature DB >> 18384410

Accuracy of linear measurement provided by cone beam computed tomography to assess bone quantity in the posterior maxilla: a human cadaver study.

Sophie Veyre-Goulet1, Thomas Fortin, Anthony Thierry.   

Abstract

PURPOSE: The aim of this study was to assess, for implant placement in the posterior maxilla, the accuracy of linear measurements provided by cone beam computed tomography (CBCT) using an image intensifier tube and television (TV) chain as an X-ray detector despite a loss of contrast resolution. The NewTom 9000 (Quantitative Radiology, Verona, Italy) was used to explore the posterior maxilla.
MATERIALS AND METHODS: Fourteen measurements were taken in three dry maxillaries. On every anatomical site, three fiducial markers were placed on the bony crest to define a plane. Dry maxillaries were submitted to CBCT imaging examination. The maxillaries were then sawn according to the previously defined planes, and bone height and width were assessed using a caliper. The same measurements were taken on images.
RESULTS: Clinical analysis demonstrated no difference between real measurements and image measurements.
CONCLUSIONS: Although cadaver bone density may not correspond to the density of vital bone, this in vitro study indicates that CBCT images provided by technique using image intensifier tube and TV chain as an X-ray detector are reliable to define the bone volume of the posterior maxilla for the purpose of planning the implant axis.

Entities:  

Mesh:

Year:  2008        PMID: 18384410     DOI: 10.1111/j.1708-8208.2008.00083.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  16 in total

1.  Comparison of mesiodistal space measurements of single-implant sites on panoramic and oblique images generated by cone-beam CT.

Authors:  Mustafa Alkhader; Malik Hudieb
Journal:  Surg Radiol Anat       Date:  2013-08-27       Impact factor: 1.246

2.  Generation of three-dimensional prototype models based on cone beam computed tomography.

Authors:  J Th Lambrecht; D C Berndt; R Schumacher; M Zehnder
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-11-15       Impact factor: 2.924

3.  Accuracy of linear measurement in the Galileos cone beam computed tomography under simulated clinical conditions.

Authors:  R Ganguly; A Ruprecht; S Vincent; J Hellstein; S Timmons; F Qian
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

4.  Three-D imaging of dental alveolar bone change after fixed orthodontic treatment in patients with periodontitis.

Authors:  Zhi-Gui Ma; Chi Yang; Bing Fang; Yun-Hui Xia; Li-Xia Mao; Yi-Miao Feng
Journal:  Int J Clin Exp Med       Date:  2015-02-15

5.  Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography.

Authors:  Dongyun Wang; Andreas Künzel; Vladimir Golubovic; Ilya Mihatovic; Gordon John; Zhuofan Chen; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2012-10-12       Impact factor: 3.573

Review 6.  Use of cone beam computed tomography in periodontology.

Authors:  Buket Acar; Kıvanç Kamburoğlu
Journal:  World J Radiol       Date:  2014-05-28

7.  Variability of dental cone beam CT grey values for density estimations.

Authors:  R Pauwels; O Nackaerts; N Bellaiche; H Stamatakis; K Tsiklakis; A Walker; H Bosmans; R Bogaerts; R Jacobs; K Horner
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

8.  Morphological and volumetric evaluation of the nasopalatinal canal in a Turkish population using cone-beam computed tomography.

Authors:  Buket Acar; Kıvanç Kamburoğlu
Journal:  Surg Radiol Anat       Date:  2014-07-20       Impact factor: 1.246

9.  Cone-beam computed tomography and microtomography for alveolar bone measurements.

Authors:  Nathália Ferrare; André Ferreira Leite; Hugo César Pinto Marques Caracas; Ricardo Bentes de Azevedo; Nilce Santos de Melo; Paulo Tadeu de Souza Figueiredo
Journal:  Surg Radiol Anat       Date:  2013-02-12       Impact factor: 1.246

10.  Quantitative Assessment of the Edentulous Posterior Maxilla for Implant Therapy: A Retrospective Cone Beam Computed Tomographic Study.

Authors:  Ninad Milind Padhye; Neel B Bhatavadekar
Journal:  J Maxillofac Oral Surg       Date:  2019-05-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.