Literature DB >> 21693401

The ultrasound brain helmet: new transducers and volume registration for in vivo simultaneous multi-transducer 3-D transcranial imaging.

Brooks D Lindsey1, Edward D Light, Heather A Nicoletto, Ellen R Bennett, Daniel T Laskowitz, Stephen W Smith.   

Abstract

Because stroke remains an important and time-sensitive health concern in developed nations, we present a system capable of fusing 3-D transcranial ultrasound volumes acquired from two sides of the head. This system uses custom sparse array transducers built on flexible multilayer circuits that can be positioned for simultaneous imaging through both temporal acoustic windows, allowing for potential registration of multiple real-time 3-D scans of cerebral vasculature. We examine hardware considerations for new matrix arrays-transducer design and interconnects-in this application. Specifically, it is proposed that SNR may be increased by reducing the length of probe cables. This claim is evaluated as part of the presented system through simulation, experimental data, and in vivo imaging. Ultimately, gains in SNR of 7 dB are realized by replacing a standard probe cable with a much shorter flex interconnect; higher gains may be possible using ribbon-based probe cables. In vivo images are presented, showing cerebral arteries with and without the use of microbubble contrast agent; they have been registered and fused using a simple algorithm which maximizes normalized cross-correlation.

Entities:  

Mesh:

Year:  2011        PMID: 21693401      PMCID: PMC3271736          DOI: 10.1109/TUFFC.2011.1929

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  50 in total

1.  Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery.

Authors:  R M Comeau; A F Sadikot; A Fenster; T M Peters
Journal:  Med Phys       Date:  2000-04       Impact factor: 4.071

2.  Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans.

Authors:  J F Aubry; M Tanter; M Pernot; J L Thomas; M Fink
Journal:  J Acoust Soc Am       Date:  2003-01       Impact factor: 1.840

3.  Adaptive focusing for transcranial ultrasound imaging using dual arrays.

Authors:  F Vignon; J F Aubry; M Tanter; A Margoum; M Fink
Journal:  J Acoust Soc Am       Date:  2006-11       Impact factor: 1.840

4.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

5.  Time reversal of ultrasonic fields. I. Basic principles.

Authors:  M Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

6.  Real-time 3-D contrast-enhanced transcranial ultrasound and aberration correction.

Authors:  Nikolas M Ivancevich; Gianmarco F Pinton; Heather A Nicoletto; Ellen Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2008-04-18       Impact factor: 2.998

7.  Automatic registration of 3-D ultrasound images.

Authors:  R N Rohling; A H Gee; L Berman
Journal:  Ultrasound Med Biol       Date:  1998-07       Impact factor: 2.998

8.  Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations.

Authors:  C R Meyer; J L Boes; B Kim; P H Bland; K R Zasadny; P V Kison; K Koral; K A Frey; R L Wahl
Journal:  Med Image Anal       Date:  1997-04       Impact factor: 8.545

9.  Trends in incidence, lifetime risk, severity, and 30-day mortality of stroke over the past 50 years.

Authors:  Raphael Carandang; Sudha Seshadri; Alexa Beiser; Margaret Kelly-Hayes; Carlos S Kase; William B Kannel; Philip A Wolf
Journal:  JAMA       Date:  2006-12-27       Impact factor: 56.272

10.  A real time system for quantifying and displaying two-dimensional velocities using ultrasound.

Authors:  L N Bohs; B H Friemel; B A McDermott; G E Trahey
Journal:  Ultrasound Med Biol       Date:  1993       Impact factor: 2.998

View more
  10 in total

1.  A super-resolution ultrasound method for brain vascular mapping.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

2.  Three-dimensional transcranial ultrasound imaging of microbubble clouds using a sparse hemispherical array.

Authors:  Meaghan A O'Reilly; Ryan M Jones; Kullervo Hynynen
Journal:  IEEE Trans Biomed Eng       Date:  2014-04       Impact factor: 4.538

3.  Simultaneous bilateral real-time 3-d transcranial ultrasound imaging at 1 MHz through poor acoustic windows.

Authors:  Brooks D Lindsey; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2013-02-13       Impact factor: 2.998

4.  3-D Intravascular Characterization of Blood Flow Velocity Fields with a Forward-Viewing 2-D Array.

Authors:  Brooks D Lindsey; Bowen Jing; Saeyoung Kim; Graham C Collins; Muralidhar Padala
Journal:  Ultrasound Med Biol       Date:  2020-06-30       Impact factor: 2.998

5.  Transfontanelle photoacoustic imaging: ultrasound transducer selection analysis.

Authors:  Rayyan Manwar; Md Tarikul Islam; Seyed Mohsen Ranjbaran; Kamran Avanaki
Journal:  Biomed Opt Express       Date:  2022-01-10       Impact factor: 3.732

6.  Pitch-catch phase aberration correction of multiple isoplanatic patches for 3-D transcranial ultrasound imaging.

Authors:  Brooks D Lindsey; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-03       Impact factor: 2.725

7.  3-D transcranial ultrasound imaging with bilateral phase aberration correction of multiple isoplanatic patches: a pilot human study with microbubble contrast enhancement.

Authors:  Brooks D Lindsey; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2013-11-14       Impact factor: 2.998

8.  Is ultrasound perfusion imaging capable of detecting mismatch? A proof-of-concept study in acute stroke patients.

Authors:  Raluca Reitmeir; Jens Eyding; Markus F Oertel; Roland Wiest; Jan Gralla; Urs Fischer; Pierre-Yves Giquel; Stefan Weber; Andreas Raabe; Heinrich P Mattle; Werner J Z'Graggen; Jürgen Beck
Journal:  J Cereb Blood Flow Metab       Date:  2016-01-01       Impact factor: 6.200

9.  Rotational-invariant speckle-scanning ultrasonography through thick bones.

Authors:  Siyi Liang; Lidai Wang
Journal:  Sci Rep       Date:  2021-07-09       Impact factor: 4.379

10.  Investigation of the Effect of the Skull in Transcranial Photoacoustic Imaging: A Preliminary Ex Vivo Study.

Authors:  Rayyan Manwar; Karl Kratkiewicz; Kamran Avanaki
Journal:  Sensors (Basel)       Date:  2020-07-28       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.