Literature DB >> 35284180

Transfontanelle photoacoustic imaging: ultrasound transducer selection analysis.

Rayyan Manwar1,2,3, Md Tarikul Islam1,4, Seyed Mohsen Ranjbaran5,2,6, Kamran Avanaki1,7,8.   

Abstract

Transfontanelle ultrasound imaging (TFUI) is the conventional approach for diagnosing brain injury in neonates. Despite being the first stage imaging modality, TFUI lacks accuracy in determining the injury at an early stage due to degraded sensitivity and specificity. Therefore, a modality like photoacoustic imaging that combines the advantages of both acoustic and optical imaging can overcome the existing TFUI limitations. Even though a variety of transducers have been used in TFUI, it is essential to identify the transducer specification that is optimal for transfontanelle imaging using the photoacoustic technique. In this study, we evaluated the performance of 6 commercially available ultrasound transducer arrays to identify the optimal characteristics for transfontanelle photoacoustic imaging. We focused on commercially available linear and phased array transducer probes with center frequencies ranging from 2.5MHz to 8.5MHz which covers the entire spectrum of the transducer arrays used for brain imaging. The probes were tested on both in vitro and ex vivo brain tissue, and their performance in terms of transducer resolution, size, penetration depth, sensitivity, signal to noise ratio, signal amplification and reconstructed image quality were evaluated. The analysis of selected transducers in these areas allowed us to determine the optimal transducer for transfontanelle imaging, based on vasculature depth and blood density in tissue using ex vivo sheep brain. The outcome of this evaluation identified the two most suitable ultrasound transducer probes for transfontanelle photoacoustic imaging.
© 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement.

Entities:  

Year:  2022        PMID: 35284180      PMCID: PMC8884197          DOI: 10.1364/BOE.446087

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  41 in total

1.  Annual summary of vital statistics: 2007.

Authors:  Melonie Heron; Paul D Sutton; Jiaquan Xu; Stephanie J Ventura; Donna M Strobino; Bernard Guyer
Journal:  Pediatrics       Date:  2009-12-21       Impact factor: 7.124

2.  The ultrasound brain helmet: new transducers and volume registration for in vivo simultaneous multi-transducer 3-D transcranial imaging.

Authors:  Brooks D Lindsey; Edward D Light; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-06       Impact factor: 2.725

3.  Double-Stage Delay Multiply and Sum Beamforming Algorithm: Application to Linear-Array Photoacoustic Imaging.

Authors:  Moein Mozaffarzadeh; Ali Mahloojifar; Mahdi Orooji; Saba Adabi; Mohammadreza Nasiriavanaki
Journal:  IEEE Trans Biomed Eng       Date:  2017-04-05       Impact factor: 4.538

4.  Predictors of neurodevelopmental outcomes in preterm infants with intraparenchymal hemorrhage.

Authors:  A J Tsai; R E Lasky; S D John; P W Evans; K A Kennedy
Journal:  J Perinatol       Date:  2014-02-20       Impact factor: 2.521

Review 5.  Hypoxic-ischemic brain injury: imaging findings from birth to adulthood.

Authors:  Benjamin Y Huang; Mauricio Castillo
Journal:  Radiographics       Date:  2008 Mar-Apr       Impact factor: 5.333

Review 6.  Brain Vascular Imaging Techniques.

Authors:  Bàrbara Laviña
Journal:  Int J Mol Sci       Date:  2016-12-30       Impact factor: 5.923

7.  A numerical analysis of a semi-dry coupling configuration in photoacoustic computed tomography for infant brain imaging.

Authors:  Najme Meimani; Nina Abani; Juri Gelovani; Mohammad R N Avanaki
Journal:  Photoacoustics       Date:  2017-06-21

8.  Skull's Photoacoustic Attenuation and Dispersion Modeling with Deterministic Ray-Tracing: Towards Real-Time Aberration Correction.

Authors:  Leila Mohammadi; Hamid Behnam; Jahan Tavakkoli; Mohammad R N Avanaki
Journal:  Sensors (Basel)       Date:  2019-01-16       Impact factor: 3.576

9.  Precision ultrasound sensing on a chip.

Authors:  Sahar Basiri-Esfahani; Ardalan Armin; Stefan Forstner; Warwick P Bowen
Journal:  Nat Commun       Date:  2019-01-10       Impact factor: 14.919

Review 10.  Photoacoustic Neuroimaging - Perspectives on a Maturing Imaging Technique and its Applications in Neuroscience.

Authors:  Silviu-Vasile Bodea; Gil Gregor Westmeyer
Journal:  Front Neurosci       Date:  2021-06-10       Impact factor: 4.677

View more
  2 in total

Review 1.  Couplants in Acoustic Biosensing Systems.

Authors:  Rayyan Manwar; Loїc Saint-Martin; Kamran Avanaki
Journal:  Chemosensors (Basel)       Date:  2022-05-09

2.  Transfontanelle photoacoustic imaging for in-vivo cerebral oxygenation measurement.

Authors:  Rayyan Manwar; Laura S McGuire; Md Tarikul Islam; Anthony Shoo; Fady T Charbel; De-Ann M Pillers; Kamran Avanaki
Journal:  Sci Rep       Date:  2022-09-13       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.