Literature DB >> 21690014

Nonrigid brain MR image registration using uniform spherical region descriptor.

Shu Liao1, Albert C S Chung.   

Abstract

There are two main issues that make nonrigid image registration a challenging task. First, voxel intensity similarity may not be necessarily equivalent to anatomical similarity in the image correspondence searching process. Second, during the imaging process, some interferences such as unexpected rotations of input volumes and monotonic gray-level bias fields can adversely affect the registration quality. In this paper, a new feature-based nonrigid image registration method is proposed. The proposed method is based on a new type of image feature, namely, uniform spherical region descriptor (USRD), as signatures for each voxel. The USRD is rotation and monotonic gray-level transformation invariant and can be efficiently calculated. The registration process is therefore formulated as a feature matching problem. The USRD feature is integrated with the Markov random field labeling framework in which energy function is defined for registration. The energy function is then optimized by the α-expansion algorithm. The proposed method has been compared with five state-of-the-art registration approaches on both the simulated and real 3-D databases obtained from the BrainWeb and Internet Brain Segmentation Repository, respectively. Experimental results demonstrate that the proposed method can achieve high registration accuracy and reliable robustness behavior.

Mesh:

Year:  2011        PMID: 21690014     DOI: 10.1109/TIP.2011.2159615

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  5 in total

Review 1.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

2.  Deformable MRI-Ultrasound registration using correlation-based attribute matching for brain shift correction: Accuracy and generality in multi-site data.

Authors:  Inês Machado; Matthew Toews; Elizabeth George; Prashin Unadkat; Walid Essayed; Jie Luo; Pedro Teodoro; Herculano Carvalho; Jorge Martins; Polina Golland; Steve Pieper; Sarah Frisken; Alexandra Golby; William Wells Iii; Yangming Ou
Journal:  Neuroimage       Date:  2019-08-22       Impact factor: 6.556

3.  Sparse patch-based label propagation for accurate prostate localization in CT images.

Authors:  Shu Liao; Yaozong Gao; Jun Lian; Dinggang Shen
Journal:  IEEE Trans Med Imaging       Date:  2012-11-27       Impact factor: 10.048

4.  Bidirectional elastic image registration using B-spline affine transformation.

Authors:  Suicheng Gu; Xin Meng; Frank C Sciurba; Hongxia Ma; Joseph Leader; Naftali Kaminski; David Gur; Jiantao Pu
Journal:  Comput Med Imaging Graph       Date:  2014-01-25       Impact factor: 4.790

5.  A Fast Subpixel Registration Algorithm Based on Single-Step DFT Combined with Phase Correlation Constraint in Multimodality Brain Image.

Authors:  Jianguo Li; Quanhai Ma
Journal:  Comput Math Methods Med       Date:  2020-05-07       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.