Literature DB >> 21666288

Extension of a data-driven gating technique to 3D, whole body PET studies.

Paul J Schleyer1, Michael J O'Doherty1, Paul K Marsden1.   

Abstract

Respiratory gating can be used to separate a PET acquisition into a series of near motion-free bins. This is typically done using additional gating hardware; however, software-based methods can derive the respiratory signal from the acquired data itself. The aim of this work was to extend a data-driven respiratory gating method to acquire gated, 3D, whole body PET images of clinical patients. The existing method, previously demonstrated with 2D, single bed-position data, uses a spectral analysis to find regions in raw PET data which are subject to respiratory motion. The change in counts over time within these regions is then used to estimate the respiratory signal of the patient. In this work, the gating method was adapted to only accept lines of response from a reduced set of axial angles, and the respiratory frequency derived from the lung bed position was used to help identify the respiratory frequency in all other bed positions. As the respiratory signal does not identify the direction of motion, a registration-based technique was developed to align the direction for all bed positions. Data from 11 clinical FDG PET patients were acquired, and an optical respiratory monitor was used to provide a hardware-based signal for comparison. All data were gated using both the data-driven and hardware methods, and reconstructed. The centre of mass of manually defined regions on gated images was calculated, and the overall displacement was defined as the change in the centre of mass between the first and last gates. The mean displacement was 10.3 mm for the data-driven gated images and 9.1 mm for the hardware gated images. No significant difference was found between the two gating methods when comparing the displacement values. The adapted data-driven gating method was demonstrated to successfully produce respiratory gated, 3D, whole body, clinical PET acquisitions.

Entities:  

Mesh:

Year:  2011        PMID: 21666288     DOI: 10.1088/0031-9155/56/13/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  The impact of audio-visual biofeedback on 4D PET images: results of a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Byungchul Cho; Youngho Seo; Paul J Keall
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

Review 2.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

3.  The relevance of data driven motion correction in diagnostic PET.

Authors:  Adam Leon Kesner
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-08-11       Impact factor: 9.236

4.  The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Samuel R Mazin; Edward E Graves; Paul J Keall
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

5.  External radioactive markers for PET data-driven respiratory gating in positron emission tomography.

Authors:  Florian Büther; Iris Ernst; James Hamill; Hans T Eich; Otmar Schober; Michael Schäfers; Klaus P Schäfers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-12-14       Impact factor: 9.236

6.  Data-driven event-by-event respiratory motion correction using TOF PET list-mode centroid of distribution.

Authors:  Silin Ren; Xiao Jin; Chung Chan; Yiqiang Jian; Tim Mulnix; Chi Liu; Richard E Carson
Journal:  Phys Med Biol       Date:  2017-05-18       Impact factor: 3.609

7.  Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study.

Authors:  S R Bowen; M J Nyflot; C Herrmann; C M Groh; J Meyer; S D Wollenweber; C W Stearns; P E Kinahan; G A Sandison
Journal:  Phys Med Biol       Date:  2015-04-17       Impact factor: 3.609

8.  Ultrasound-based sensors for respiratory motion assessment in multimodality PET imaging.

Authors:  Bruno Madore; Gabriela Belsley; Cheng-Chieh Cheng; Frank Preiswerk; Marie Foley Kijewski; Pei-Hsin Wu; Laurel B Martell; Josien P W Pluim; Marcelo Di Carli; Stephen C Moore
Journal:  Phys Med Biol       Date:  2022-01-19       Impact factor: 4.174

Review 9.  Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Authors:  Irene Polycarpou; Georgios Soultanidis; Charalampos Tsoumpas
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-07-05       Impact factor: 4.226

10.  Gating, enhanced gating, and beyond: information utilization strategies for motion management, applied to preclinical PET.

Authors:  Adam Leon Kesner; Galith Abourbeh; Eyal Mishani; Roland Chisin; Sagi Tshori; Nanette Freedman
Journal:  EJNMMI Res       Date:  2013-04-24       Impact factor: 3.138

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.