Literature DB >> 28520558

Data-driven event-by-event respiratory motion correction using TOF PET list-mode centroid of distribution.

Silin Ren1, Xiao Jin, Chung Chan, Yiqiang Jian, Tim Mulnix, Chi Liu, Richard E Carson.   

Abstract

Data-driven respiratory gating techniques were developed to correct for respiratory motion in PET studies, without the help of external motion tracking systems. Due to the greatly increased image noise in gated reconstructions, it is desirable to develop a data-driven event-by-event respiratory motion correction method. In this study, using the Centroid-of-distribution (COD) algorithm, we established a data-driven event-by-event respiratory motion correction technique using TOF PET list-mode data, and investigated its performance by comparing with an external system-based correction method. Ten human scans with the pancreatic β-cell tracer 18F-FP-(+)-DTBZ were employed. Data-driven respiratory motions in superior-inferior (SI) and anterior-posterior (AP) directions were first determined by computing the centroid of all radioactive events during each short time frame with further processing. The Anzai belt system was employed to record respiratory motion in all studies. COD traces in both SI and AP directions were first compared with Anzai traces by computing the Pearson correlation coefficients. Then, respiratory gated reconstructions based on either COD or Anzai traces were performed to evaluate their relative performance in capturing respiratory motion. Finally, based on correlations of displacements of organ locations in all directions and COD information, continuous 3D internal organ motion in SI and AP directions was calculated based on COD traces to guide event-by-event respiratory motion correction in the MOLAR reconstruction framework. Continuous respiratory correction results based on COD were compared with that based on Anzai, and without motion correction. Data-driven COD traces showed a good correlation with Anzai in both SI and AP directions for the majority of studies, with correlation coefficients ranging from 63% to 89%. Based on the determined respiratory displacements of pancreas between end-expiration and end-inspiration from gated reconstructions, there was no significant difference between COD-based and Anzai-based methods. Finally, data-driven COD-based event-by-event respiratory motion correction yielded comparable results to that based on Anzai respiratory traces, in terms of contrast recovery and reduced motion-induced blur. Data-driven event-by-event respiratory motion correction using COD showed significant image quality improvement compared with reconstructions with no motion correction, and gave comparable results to the Anzai-based method.

Entities:  

Mesh:

Year:  2017        PMID: 28520558      PMCID: PMC6048592          DOI: 10.1088/1361-6560/aa700c

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images.

Authors:  Torsten Rohlfing; Calvin R Maurer; Walter G O'Dell; Jianhui Zhong
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

2.  A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods.

Authors:  Adam Leon Kesner; Claudia Kuntner
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Extracting a respiratory signal from raw dynamic PET data that contain tracer kinetics.

Authors:  P J Schleyer; K Thielemans; P K Marsden
Journal:  Phys Med Biol       Date:  2014-07-17       Impact factor: 3.609

4.  Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography.

Authors:  Florian Büther; Iris Ernst; Mohammad Dawood; Peter Kraxner; Michael Schäfers; Otmar Schober; Klaus P Schäfers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-07-06       Impact factor: 9.236

5.  Postacquisition detection of tumor motion in the lung and upper abdomen using list-mode PET data: a feasibility study.

Authors:  Ralph A Bundschuh; Axel Martínez-Moeller; Markus Essler; María-José Martínez; Stephan G Nekolla; Sibylle I Ziegler; Markus Schwaiger
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

6.  Respiratory gating in positron emission tomography: a quantitative comparison of different gating schemes.

Authors:  Mohammad Dawood; Florian Büther; Norbert Lang; Otmar Schober; Klaus P Schäfers
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

7.  Retrospective data-driven respiratory gating for PET/CT.

Authors:  Paul J Schleyer; Michael J O'Doherty; Sally F Barrington; Paul K Marsden
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

8.  List-mode reconstruction for the Biograph mCT with physics modeling and event-by-event motion correction.

Authors:  Xiao Jin; Chung Chan; Tim Mulnix; Vladimir Panin; Michael E Casey; Chi Liu; Richard E Carson
Journal:  Phys Med Biol       Date:  2013-07-29       Impact factor: 3.609

9.  In vivo imaging of endogenous pancreatic β-cell mass in healthy and type 1 diabetic subjects using 18F-fluoropropyl-dihydrotetrabenazine and PET.

Authors:  Marc D Normandin; Kitt F Petersen; Yu-Shin Ding; Shu-Fei Lin; Sarita Naik; Krista Fowles; Daniel M Skovronsky; Kevan C Herold; Timothy J McCarthy; Roberto A Calle; Richard E Carson; Judith L Treadway; Gary W Cline
Journal:  J Nucl Med       Date:  2012-05-09       Impact factor: 10.057

10.  Extension of a data-driven gating technique to 3D, whole body PET studies.

Authors:  Paul J Schleyer; Michael J O'Doherty; Paul K Marsden
Journal:  Phys Med Biol       Date:  2011-06-10       Impact factor: 3.609

View more
  13 in total

1.  The relevance of data driven motion correction in diagnostic PET.

Authors:  Adam Leon Kesner
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-08-11       Impact factor: 9.236

2.  Ultrasound-based sensors for respiratory motion assessment in multimodality PET imaging.

Authors:  Bruno Madore; Gabriela Belsley; Cheng-Chieh Cheng; Frank Preiswerk; Marie Foley Kijewski; Pei-Hsin Wu; Laurel B Martell; Josien P W Pluim; Marcelo Di Carli; Stephen C Moore
Journal:  Phys Med Biol       Date:  2022-01-19       Impact factor: 4.174

3.  Evaluation of PET Brain Radioligands for Imaging Pancreatic β-Cell Mass: Potential Utility of 11C-(+)-PHNO.

Authors:  Jason Bini; Mika Naganawa; Nabeel Nabulsi; Yiyun Huang; Jim Ropchan; Keunpoong Lim; Soheila Najafzadeh; Kevan C Herold; Gary W Cline; Richard E Carson
Journal:  J Nucl Med       Date:  2018-01-25       Impact factor: 10.057

4.  Developing an efficient phase-matched attenuation correction method for quiescent period PET in abdominal PET/MRI.

Authors:  Jaewon Yang; Jing Liu; Florian Wiesinger; Anne Menini; Xucheng Zhu; Thomas A Hope; Youngho Seo; Peder E Z Larson
Journal:  Phys Med Biol       Date:  2018-09-10       Impact factor: 3.609

5.  Data-Driven Motion Detection and Event-by-Event Correction for Brain PET: Comparison with Vicra.

Authors:  Yihuan Lu; Mika Naganawa; Takuya Toyonaga; Jean-Dominique Gallezot; Kathryn Fontaine; Silin Ren; Enette Mae Revilla; Tim Mulnix; Richard E Carson
Journal:  J Nucl Med       Date:  2020-01-31       Impact factor: 11.082

Review 6.  Total-Body PET Kinetic Modeling and Potential Opportunities Using Deep Learning.

Authors:  Yiran Wang; Elizabeth Li; Simon R Cherry; Guobao Wang
Journal:  PET Clin       Date:  2021-08-03

7.  Clinical and scientific value in the pursuit of quantification of beta cells in the pancreas by PET imaging.

Authors:  Gary W Cline; Timothy J McCarthy; Richard E Carson; Roberto A Calle
Journal:  Diabetologia       Date:  2018-08-22       Impact factor: 10.460

8.  New PET technologies - embracing progress and pushing the limits.

Authors:  Nicolas Aide; Charline Lasnon; Adam Kesner; Craig S Levin; Irene Buvat; Andrei Iagaru; Ken Hermann; Ramsey D Badawi; Simon R Cherry; Kevin M Bradley; Daniel R McGowan
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-06-03       Impact factor: 9.236

9.  Evaluation of principal component analysis-based data-driven respiratory gating for positron emission tomography.

Authors:  Matthew D Walker; Kevin M Bradley; Daniel R McGowan
Journal:  Br J Radiol       Date:  2018-03-15       Impact factor: 3.039

10.  Evaluation of data-driven respiratory gating waveforms for clinical PET imaging.

Authors:  Matthew D Walker; Andrew J Morgan; Kevin M Bradley; Daniel R McGowan
Journal:  EJNMMI Res       Date:  2019-01-03       Impact factor: 3.138

View more