Rapid frequency scan EPR.

Mark Tseitlin1, George A Rinard, Richard W Quine, Sandra S Eaton, Gareth R Eaton.   

Abstract

In rapid frequency scan EPR with triangular scans, sufficient time must be allowed to insure that the magnetization in the x, y plane decays to baseline at the end of the scan, which typically is about 5T(2) after the spins are excited. To permit relaxation of signals excited toward the extremes of the scan the total scan time required may be much longer than 5T(2). However, with periodic, saw-tooth excitation, the slow-scan EPR spectrum can be recovered by Fourier deconvolution of data recorded with a total scan period of 5T(2), even if some spins are excited later in the scan. This scan time is similar to polyphase excitation methods. The peak power required for either polyphase excitation or rapid frequency scans is substantially smaller than for pulsed EPR. The use of an arbitrary waveform generator (AWG) and cross loop resonator facilitated implementation of the rapid frequency scan experiments reported here. The use of constant continuous low B(1), periodic excitation waveform, and constant external magnetic field is similar to polyphase excitation, but could be implemented without the AWG that is required for polyphase excitation.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21664848      PMCID: PMC3145835          DOI: 10.1016/j.jmr.2011.05.006

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  12 in total

1.  An L-band crossed-loop (Bimodal) EPR resonator.

Authors:  G A Rinard; R W Quine; G R Eaton
Journal:  J Magn Reson       Date:  2000-05       Impact factor: 2.229

2.  W-band frequency-swept EPR.

Authors:  James S Hyde; Robert A Strangeway; Theodore G Camenisch; Joseph J Ratke; Wojciech Froncisz
Journal:  J Magn Reson       Date:  2010-04-13       Impact factor: 2.229

3.  Comparison of Continuous Wave, Spin Echo, and Rapid Scan EPR of Irradiated Fused Quartz.

Authors:  Deborah G Mitchell; Richard W Quine; Mark Tseitlin; Virginia Meyer; Sandra S Eaton; Gareth R Eaton
Journal:  Radiat Meas       Date:  2011-09       Impact factor: 1.898

4.  Digital detection and processing of multiple quadrature harmonics for EPR spectroscopy.

Authors:  R Ahmad; S Som; E Kesselring; P Kuppusamy; J L Zweier; L C Potter
Journal:  J Magn Reson       Date:  2010-09-29       Impact factor: 2.229

5.  NMR with excitation modulated by Frank sequences.

Authors:  Bernhard Blümich; Qingxia Gong; Eimear Byrne; Marcus Greferath
Journal:  J Magn Reson       Date:  2009-03-28       Impact factor: 2.229

6.  Use of polyphase continuous excitation based on the Frank sequence in EPR.

Authors:  Mark Tseitlin; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-06-12       Impact factor: 2.229

7.  Reconstruction of the first-derivative EPR spectrum from multiple harmonics of the field-modulated continuous wave signal.

Authors:  Mark Tseitlin; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-02-03       Impact factor: 2.229

8.  Deconvolution of sinusoidal rapid EPR scans.

Authors:  Mark Tseitlin; George A Rinard; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2010-11-26       Impact factor: 2.229

9.  Rapid-scan EPR with triangular scans and fourier deconvolution to recover the slow-scan spectrum.

Authors:  Janhavi P Joshi; John R Ballard; George A Rinard; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2005-04-14       Impact factor: 2.229

10.  Direct-detected rapid-scan EPR at 250 MHz.

Authors:  James W Stoner; Dennis Szymanski; Sandra S Eaton; Richard W Quine; George A Rinard; Gareth R Eaton
Journal:  J Magn Reson       Date:  2004-09       Impact factor: 2.229

View more
  6 in total

1.  The Instrument Set for Generating Fast Adiabatic Passage.

Authors:  T Czechowski; M Baranowski; A Woźniak-Braszak; K Jurga; J Jurga; P Kędzia
Journal:  Appl Magn Reson       Date:  2012-07-13       Impact factor: 0.831

2.  Digital EPR with an arbitrary waveform generator and direct detection at the carrier frequency.

Authors:  Mark Tseitlin; Richard W Quine; George A Rinard; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-09-14       Impact factor: 2.229

Review 3.  Rapid-scan EPR imaging.

Authors:  Sandra S Eaton; Yilin Shi; Lukas Woodcock; Laura A Buchanan; Joseph McPeak; Richard W Quine; George A Rinard; Boris Epel; Howard J Halpern; Gareth R Eaton
Journal:  J Magn Reson       Date:  2017-07       Impact factor: 2.229

4.  Decoupling of excitation and receive coils in pulsed magnetic resonance using sinusoidal magnetic field modulation.

Authors:  Mark Tseytlin; Boris Epel; Subramanian Sundramoorthy; Dmitriy Tipikin; Howard J Halpern
Journal:  J Magn Reson       Date:  2016-09-07       Impact factor: 2.229

Review 5.  EPR Everywhere.

Authors:  Joshua R Biller; Joseph E McPeak
Journal:  Appl Magn Reson       Date:  2021-01-24       Impact factor: 0.831

6.  Broadband transmission EPR spectroscopy.

Authors:  Wilfred R Hagen
Journal:  PLoS One       Date:  2013-03-21       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.