Literature DB >> 20971667

Digital detection and processing of multiple quadrature harmonics for EPR spectroscopy.

R Ahmad1, S Som, E Kesselring, P Kuppusamy, J L Zweier, L C Potter.   

Abstract

A quadrature digital receiver and associated signal estimation procedure are reported for L-band electron paramagnetic resonance (EPR) spectroscopy. The approach provides simultaneous acquisition and joint processing of multiple harmonics in both in-phase and out-of-phase channels. The digital receiver, based on a high-speed dual-channel analog-to-digital converter, allows direct digital down-conversion with heterodyne processing using digital capture of the microwave reference signal. Thus, the receiver avoids noise and nonlinearity associated with analog mixers. Also, the architecture allows for low-Q anti-alias filtering and does not require the sampling frequency to be time-locked to the microwave reference. A noise model applicable for arbitrary contributions of oscillator phase noise is presented, and a corresponding maximum-likelihood estimator of unknown parameters is also reported. The signal processing is applicable for Lorentzian lineshape under nonsaturating conditions. The estimation is carried out using a convergent iterative algorithm capable of jointly processing the in-phase and out-of-phase data in the presence of phase noise and unknown microwave phase. Cramér-Rao bound analysis and simulation results demonstrate a significant reduction in linewidth estimation error using quadrature detection, for both low and high values of phase noise. EPR spectroscopic data are also reported for illustration.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20971667      PMCID: PMC2993834          DOI: 10.1016/j.jmr.2010.09.016

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  16 in total

1.  High spatial resolution multi-site EPR oximetry. The use of convolution-based fitting method.

Authors:  O Y Grinberg; A I Smirnov; H M Swartz
Journal:  J Magn Reson       Date:  2001-10       Impact factor: 2.229

2.  Analysis of the tuning and operation of reflection resonator EPR spectrometers.

Authors:  Vladimir Krymov; Gary J Gerfen
Journal:  J Magn Reson       Date:  2003-06       Impact factor: 2.229

3.  Application of magnetic field over-modulation for improved EPR linewidth measurements using probes with Lorentzian lineshape.

Authors:  Yuanmu Deng; Ramasamy P Pandian; Rizwan Ahmad; Periannan Kuppusamy; Jay L Zweier
Journal:  J Magn Reson       Date:  2006-06-08       Impact factor: 2.229

4.  Progressive EPR imaging with adaptive projection acquisition.

Authors:  Yuanmu Deng; Periannan Kuppusamy; Jay L Zweier
Journal:  J Magn Reson       Date:  2005-06       Impact factor: 2.229

5.  A parametric approach to spectral-spatial EPR imaging.

Authors:  Subhojit Som; Lee C Potter; Rizwan Ahmad; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2007-01-12       Impact factor: 2.229

Review 6.  Theory, instrumentation, and applications of electron paramagnetic resonance oximetry.

Authors:  Rizwan Ahmad; Periannan Kuppusamy
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

7.  Effect of nitrogen dioxide on the EPR property of lithium octa-n-butoxy 2,3-naphthalocyanine (LiNc-BuO) microcrystals.

Authors:  Ramasamy P Pandian; Vinh Dang; Periakaruppan T Manoharan; Jay L Zweier; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2006-05-11       Impact factor: 2.229

8.  DANCING WITH THE ELECTRONS: TIME-DOMAIN AND CW IN VIVO EPR IMAGING.

Authors:  Sankaran Subramanian; Murali C Krishna
Journal:  Magn Reson Insights       Date:  2008-09-24

9.  Rapid-scan EPR with triangular scans and fourier deconvolution to recover the slow-scan spectrum.

Authors:  Janhavi P Joshi; John R Ballard; George A Rinard; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2005-04-14       Impact factor: 2.229

10.  Electron paramagnetic resonance oxygen image hypoxic fraction plus radiation dose strongly correlates with tumor cure in FSa fibrosarcomas.

Authors:  Martyna Elas; Rebecca Bell; Danielle Hleihel; Eugene D Barth; Colin McFaul; Chad R Haney; Joanna Bielanska; Katarzyna Pustelny; Kang-Hyun Ahn; Charles A Pelizzari; Masha Kocherginsky; Howard J Halpern
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-06-01       Impact factor: 7.038

View more
  11 in total

1.  Use of polyphase continuous excitation based on the Frank sequence in EPR.

Authors:  Mark Tseitlin; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-06-12       Impact factor: 2.229

2.  The world as viewed by and with unpaired electrons.

Authors:  Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2012-08-15       Impact factor: 2.229

3.  Reconstruction of the first-derivative EPR spectrum from multiple harmonics of the field-modulated continuous wave signal.

Authors:  Mark Tseitlin; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-02-03       Impact factor: 2.229

4.  Rapid frequency scan EPR.

Authors:  Mark Tseitlin; George A Rinard; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-05-19       Impact factor: 2.229

5.  Dual-scan acquisition for accelerated continuous-wave EPR oximetry.

Authors:  J Palmer; L C Potter; D H Johnson; J L Zweier; R Ahmad
Journal:  J Magn Reson       Date:  2012-06-13       Impact factor: 2.229

6.  Digital EPR with an arbitrary waveform generator and direct detection at the carrier frequency.

Authors:  Mark Tseitlin; Richard W Quine; George A Rinard; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-09-14       Impact factor: 2.229

7.  Multisite EPR oximetry from multiple quadrature harmonics.

Authors:  R Ahmad; S Som; D H Johnson; J L Zweier; P Kuppusamy; L C Potter
Journal:  J Magn Reson       Date:  2011-11-15       Impact factor: 2.229

8.  Optimization of magnetic field sweep and field modulation amplitude for continuous-wave EPR oximetry.

Authors:  J Palmer; L C Potter; R Ahmad
Journal:  J Magn Reson       Date:  2011-01-26       Impact factor: 2.229

9.  Digitally generated excitation and near-baseband quadrature detection of rapid scan EPR signals.

Authors:  Mark Tseitlin; Zhelin Yu; Richard W Quine; George A Rinard; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2014-10-30       Impact factor: 2.229

10.  Dispersion EPR: Considerations for Low-Frequency Experiments.

Authors:  James S Hyde; Robert A Strangeway; Jason W Sidabras
Journal:  Appl Magn Reson       Date:  2021-05-29       Impact factor: 0.974

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.