Literature DB >> 21656557

Temporal SNR characteristics in segmented 3D-EPI at 7T.

W van der Zwaag1, J P Marques, T Kober, G Glover, R Gruetter, G Krueger.   

Abstract

Three-dimensional segmented echo planar imaging (3D-EPI) is a promising approach for high-resolution functional magnetic resonance imaging, as it provides an increased signal-to-noise ratio (SNR) at similar temporal resolution to traditional multislice 2D-EPI readouts. Recently, the 3D-EPI technique has become more frequently used and it is important to better understand its implications for fMRI. In this study, the temporal SNR characteristics of 3D-EPI with varying numbers of segments are studied. It is shown that, in humans, the temporal variance increases with the number of segments used to form the EPI acquisition and that for segmented acquisitions, the maximum available temporal SNR is reduced compared to single shot acquisitions. This reduction with increased segmentation is not found in phantom data and thus likely due to physiological processes. When operating in the thermal noise dominated regime, fMRI experiments with a motor task revealed that the 3D variant outperforms the 2D-EPI in terms of temporal SNR and sensitivity to detect activated brain regions. Thus, the theoretical SNR advantage of a segmented 3D-EPI sequence for fMRI only exists in a low SNR situation. However, other advantages of 3D-EPI, such as the application of parallel imaging techniques in two dimensions and the low specific absorption rate requirements, may encourage the use of the 3D-EPI sequence for fMRI in situations with higher SNR.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21656557      PMCID: PMC3627735          DOI: 10.1002/mrm.23007

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  29 in total

1.  Neuroimaging at 1.5 T and 3.0 T: comparison of oxygenation-sensitive magnetic resonance imaging.

Authors:  G Krüger; A Kastrup; G H Glover
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Accurate phosphorus metabolite images of the human heart by 3D acquisition-weighted CSI.

Authors:  R Pohmann; M von Kienlin
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

3.  Temporal autocorrelation in univariate linear modeling of FMRI data.

Authors:  M W Woolrich; B D Ripley; M Brady; S M Smith
Journal:  Neuroimage       Date:  2001-12       Impact factor: 6.556

4.  Physiological noise in oxygenation-sensitive magnetic resonance imaging.

Authors:  G Krüger; G H Glover
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

5.  Improvement of temporal resolution in fMRI using slice phase encode reordered 3D EPI.

Authors:  L T Muftuler; O Nalcioglu
Journal:  Magn Reson Med       Date:  2000-09       Impact factor: 4.668

6.  Improved optimization for the robust and accurate linear registration and motion correction of brain images.

Authors:  Mark Jenkinson; Peter Bannister; Michael Brady; Stephen Smith
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

7.  Zoomed functional imaging in the human brain at 7 Tesla with simultaneous high spatial and high temporal resolution.

Authors:  Josef Pfeuffer; Pierre-Francois van de Moortele; Essa Yacoub; Amir Shmuel; Gregor Adriany; Peter Andersen; Hellmut Merkle; Michael Garwood; Kamil Ugurbil; Xiaoping Hu
Journal:  Neuroimage       Date:  2002-09       Impact factor: 6.556

8.  Three dimensional echo-planar imaging at 7 Tesla.

Authors:  B A Poser; P J Koopmans; T Witzel; L L Wald; M Barth
Journal:  Neuroimage       Date:  2010-02-06       Impact factor: 6.556

9.  T2-weighted 3D fMRI using S2-SSFP at 7 tesla.

Authors:  Markus Barth; Heiko Meyer; Stephan A R Kannengiesser; Jonathan R Polimeni; Lawrence L Wald; David G Norris
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

10.  Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils.

Authors:  Christina Triantafyllou; Jonathan R Polimeni; Lawrence L Wald
Journal:  Neuroimage       Date:  2010-12-16       Impact factor: 6.556

View more
  25 in total

Review 1.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

2.  Physiological noise in human cerebellar fMRI.

Authors:  Wietske van der Zwaag; João Jorge; Denis Butticaz; Rolf Gruetter
Journal:  MAGMA       Date:  2015-04-18       Impact factor: 2.310

3.  SENSE and simultaneous multislice imaging.

Authors:  Benjamin Zahneisen; Thomas Ernst; Benedikt A Poser
Journal:  Magn Reson Med       Date:  2014-11-05       Impact factor: 4.668

4.  Techniques for blood volume fMRI with VASO: From low-resolution mapping towards sub-millimeter layer-dependent applications.

Authors:  Laurentius Huber; Dimo Ivanov; Daniel A Handwerker; Sean Marrett; Maria Guidi; Kâmil Uludağ; Peter A Bandettini; Benedikt A Poser
Journal:  Neuroimage       Date:  2016-11-18       Impact factor: 6.556

Review 5.  Methods for cleaning the BOLD fMRI signal.

Authors:  César Caballero-Gaudes; Richard C Reynolds
Journal:  Neuroimage       Date:  2016-12-09       Impact factor: 6.556

Review 6.  Rapid brain MRI acquisition techniques at ultra-high fields.

Authors:  Kawin Setsompop; David A Feinberg; Jonathan R Polimeni
Journal:  NMR Biomed       Date:  2016-02-02       Impact factor: 4.044

7.  Dynamic distortion correction for functional MRI using FID navigators.

Authors:  Tess E Wallace; Jonathan R Polimeni; Jason P Stockmann; W Scott Hoge; Tobias Kober; Simon K Warfield; Onur Afacan
Journal:  Magn Reson Med       Date:  2020-09-24       Impact factor: 4.668

Review 8.  New acquisition techniques and their prospects for the achievable resolution of fMRI.

Authors:  Saskia Bollmann; Markus Barth
Journal:  Prog Neurobiol       Date:  2020-10-23       Impact factor: 11.685

9.  Ultra-high spatial resolution BOLD fMRI in humans using combined segmented-accelerated VFA-FLEET with a recursive RF pulse design.

Authors:  Avery J L Berman; William A Grissom; Thomas Witzel; Shahin Nasr; Daniel J Park; Kawin Setsompop; Jonathan R Polimeni
Journal:  Magn Reson Med       Date:  2020-07-23       Impact factor: 4.668

10.  Single-scan MRI with exceptional resilience to field heterogeneities.

Authors:  Zhiyong Zhang; Amir Seginer; Lucio Frydman
Journal:  Magn Reson Med       Date:  2016-02-22       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.