Literature DB >> 20373402

T2-weighted 3D fMRI using S2-SSFP at 7 tesla.

Markus Barth1, Heiko Meyer, Stephan A R Kannengiesser, Jonathan R Polimeni, Lawrence L Wald, David G Norris.   

Abstract

In this study, the sensitivity of the S(2)-steady-state free precession (SSFP) signal for functional MRI at 7 T was investigated. In order to achieve the necessary temporal resolution, a three-dimensional acquisition scheme with acceleration along two spatial axes was employed. Activation maps based on S(2)-steady-state free precession data showed similar spatial localization of activation and sensitivity as spin-echo echo-planar imaging (SE-EPI), but data can be acquired with substantially lower power deposition. The functional sensitivity estimated by the average z-values was not significantly different for SE-EPI compared to the S(2)-signal but was slightly lower for the S(2)-signal (6.74 +/- 0.32 for the TR = 15 ms protocol and 7.51 +/- 0.78 for the TR = 27 ms protocol) compared to SE-EPI (7.49 +/- 1.44 and 8.05 +/- 1.67) using the same activated voxels, respectively. The relative signal changes in these voxels upon activation were slightly lower for SE-EPI (2.37% +/- 0.18%) compared to the TR = 15 ms S(2)-SSFP protocol (2.75% +/- 0.53%) and significantly lower than the TR = 27 ms protocol (5.38% +/- 1.28%), in line with simulations results. The large relative signal change for the long TR SSFP protocol can be explained by contributions from multiple coherence pathways and the low intrinsic intensity of the S(2) signal. In conclusion, whole-brain T(2)-weighted functional MRI with negligible image distortion at 7 T is feasible using the S(2)-SSFP sequence and partially parallel imaging.

Entities:  

Mesh:

Year:  2010        PMID: 20373402      PMCID: PMC2852274          DOI: 10.1002/mrm.22283

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Detection of BOLD changes by means of a frequency-sensitive trueFISP technique: preliminary results.

Authors:  K Scheffler; E Seifritz; D Bilecen; R Venkatesan; J Hennig; M Deimling; E M Haacke
Journal:  NMR Biomed       Date:  2001 Nov-Dec       Impact factor: 4.044

3.  Functional brain imaging using a blood oxygenation sensitive steady state.

Authors:  Karla L Miller; Brian A Hargreaves; Jongho Lee; David Ress; R Christopher deCharms; John M Pauly
Journal:  Magn Reson Med       Date:  2003-10       Impact factor: 4.668

4.  Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans.

Authors:  Essa Yacoub; Pierre-Francois Van De Moortele; Amir Shmuel; Kâmil Uğurbil
Journal:  Neuroimage       Date:  2005-02-01       Impact factor: 6.556

Review 5.  Advances in functional and structural MR image analysis and implementation as FSL.

Authors:  Stephen M Smith; Mark Jenkinson; Mark W Woolrich; Christian F Beckmann; Timothy E J Behrens; Heidi Johansen-Berg; Peter R Bannister; Marilena De Luca; Ivana Drobnjak; David E Flitney; Rami K Niazy; James Saunders; John Vickers; Yongyue Zhang; Nicola De Stefano; J Michael Brady; Paul M Matthews
Journal:  Neuroimage       Date:  2004       Impact factor: 6.556

6.  Motion-insensitive, steady-state free precession imaging.

Authors:  Y Zur; M L Wood; L J Neuringer
Journal:  Magn Reson Med       Date:  1990-12       Impact factor: 4.668

7.  FADE--a new fast imaging sequence.

Authors:  T W Redpath; R A Jones
Journal:  Magn Reson Med       Date:  1988-02       Impact factor: 4.668

8.  The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences.

Authors:  M L Gyngell
Journal:  Magn Reson Imaging       Date:  1988 Jul-Aug       Impact factor: 2.546

9.  3-dimensional functional imaging of human brain using echo-shifted FLASH MRI.

Authors:  J H Duyn; V S Mattay; R H Sexton; G S Sobering; F A Barrios; G Liu; J A Frank; D R Weinberger; C T Moonen
Journal:  Magn Reson Med       Date:  1994-07       Impact factor: 4.668

10.  Water proton T1 measurements in brain tissue at 7, 3, and 1.5 T using IR-EPI, IR-TSE, and MPRAGE: results and optimization.

Authors:  P J Wright; O E Mougin; J J Totman; A M Peters; M J Brookes; R Coxon; P E Morris; M Clemence; S T Francis; R W Bowtell; P A Gowland
Journal:  MAGMA       Date:  2008-02-08       Impact factor: 2.310

View more
  13 in total

1.  Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging.

Authors:  Conrad Martin; Tobias Frauenrath; Celal Ozerdem; Wolfgang Renz; Thoralf Niendorf
Journal:  Eur Radiol       Date:  2011-06-08       Impact factor: 5.315

2.  Modeling and suppression of respiration induced B0-fluctuations in non-balanced steady-state free precession sequences at 7 Tesla.

Authors:  Pål Erik Goa; Benedikt Andreas Poser; Markus Barth
Journal:  MAGMA       Date:  2012-09-25       Impact factor: 2.310

3.  Integrated SSFP for functional brain mapping at 7T with reduced susceptibility artifact.

Authors:  Kaibao Sun; Rong Xue; Peng Zhang; Zhentao Zuo; Zhongwei Chen; Bo Wang; Thomas Martin; Yi Wang; Lin Chen; Sheng He; Danny J J Wang
Journal:  J Magn Reson       Date:  2016-12-30       Impact factor: 2.229

4.  Whole-brain three-dimensional T2-weighted BOLD functional magnetic resonance imaging at 7 Tesla.

Authors:  Jun Hua; Qin Qin; Peter C M van Zijl; James J Pekar; Craig K Jones
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

5.  Variable flip angle 3D-GRASE for high resolution fMRI at 7 tesla.

Authors:  Valentin G Kemper; Federico De Martino; Essa Yacoub; Rainer Goebel
Journal:  Magn Reson Med       Date:  2015-09-21       Impact factor: 4.668

6.  Temporal SNR characteristics in segmented 3D-EPI at 7T.

Authors:  W van der Zwaag; J P Marques; T Kober; G Glover; R Gruetter; G Krueger
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

Review 7.  Pulse sequences and parallel imaging for high spatiotemporal resolution MRI at ultra-high field.

Authors:  Benedikt A Poser; Kawin Setsompop
Journal:  Neuroimage       Date:  2017-04-06       Impact factor: 6.556

Review 8.  New acquisition techniques and their prospects for the achievable resolution of fMRI.

Authors:  Saskia Bollmann; Markus Barth
Journal:  Prog Neurobiol       Date:  2020-10-23       Impact factor: 11.685

Review 9.  FMRI using balanced steady-state free precession (SSFP).

Authors:  Karla L Miller
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

10.  Optimizing RetroICor and RetroKCor corrections for multi-shot 3D FMRI acquisitions.

Authors:  Rob H N Tijssen; Mark Jenkinson; Jonathan C W Brooks; Peter Jezzard; Karla L Miller
Journal:  Neuroimage       Date:  2013-09-07       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.