Literature DB >> 21656265

Bone texture analysis of human femurs using a new device (BMA™) improves failure load prediction.

S Kolta1, S Paratte, T Amphoux, S Persohn, S Campana, W Skalli, S Paternotte, J-N Argenson, J-M Bouler, O Gagey, C Roux.   

Abstract

UNLABELLED: We measured bone texture parameters of excised human femurs with a new device (BMA™). We also measured bone mineral density by DXA and investigated the performance of these parameters in the prediction of failure load. Our results suggest that bone texture parameters improve failure load prediction when added to bone mineral density.
INTRODUCTION: Bone mineral density (BMD) is a strong determinant of bone strength. However, nearly half of the fractures occur in patients with BMD which does not reach the osteoporotic threshold. In order to assess fracture risk properly, other factors are important to be taken into account such as clinical risk factors as well as macro- and microarchitecture of bone. Bone microarchitecture is usually assessed by high-resolution QCT, but this cannot be applied in routine clinical settings due to irradiation, cost and availability concerns. Texture analysis of bone has shown to be correlated to bone strength.
METHODS: We used a new device to get digitized X-rays of 12 excised human femurs in order to measure bone texture parameters in three different regions of interest (ROIs). We investigated the performance of these parameters in the prediction of the failure load using biomechanical tests. Texture parameters measured were the fractal dimension (Hmean), the co-occurrence matrix, and the run length matrix. We also measured bone mineral density by DXA in the same ROIs as well as in standard DXA hip regions.
RESULTS: The Spearman correlation coefficient between BMD and texture parameters measured in the same ROIs ranged from -0.05 (nonsignificant (NS)) to 0.57 (p = 0.003). There was no correlation between Hmean and co-occurrence matrix nor Hmean and run length matrix in the same ROI (r = -0.04 to 0.52, NS). Co-occurrence matrix and run length matrix in the same ROI were highly correlated (r = 0.90 to 0.99, p < 0.0001). Univariate analysis with the failure load revealed significant correlation only with BMD results, not texture parameters. Multiple regression analysis showed that the best predictors of failure load were BMD, Hmean, and run length matrix at the femoral neck, as well as age and sex, with an adjusted r (2) = 0.88. Added to femoral neck BMD, Hmean and run length matrix at the femoral neck (without the effect of age and sex) improved failure load prediction (compared to femoral neck BMD alone) from adjusted r (2) = 0.67 to adjusted r (2) = 0.84.
CONCLUSION: Our results suggest that bone texture measurement improves failure load prediction when added to BMD.

Entities:  

Mesh:

Year:  2011        PMID: 21656265     DOI: 10.1007/s00198-011-1674-2

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  36 in total

1.  Correlation of femoral and lumbar DXA and calcaneal ultrasound, measured in situ with intact soft tissues, with the in vitro failure loads of the proximal femur.

Authors:  E M Lochmüller; J B Zeller; D Kaiser; F Eckstein; J Landgraf; R Putz; R Steldinger
Journal:  Osteoporos Int       Date:  1998       Impact factor: 4.507

Review 2.  Imaging techniques for evaluating bone microarchitecture.

Authors:  Eric Lespessailles; Christine Chappard; Nicolas Bonnet; Claude Laurent Benhamou
Journal:  Joint Bone Spine       Date:  2006-01-13       Impact factor: 4.929

3.  Correlations between grey-level variations in 2D projection images (TBS) and 3D microarchitecture: applications in the study of human trabecular bone microarchitecture.

Authors:  Laurent Pothuaud; Pascal Carceller; Didier Hans
Journal:  Bone       Date:  2008-01-29       Impact factor: 4.398

4.  Femoroplasty--augmentation of the proximal femur with a composite bone cement--feasibility, biomechanical properties and osteosynthesis potential.

Authors:  J Beckmann; S J Ferguson; M Gebauer; C Luering; B Gasser; P Heini
Journal:  Med Eng Phys       Date:  2006-10-04       Impact factor: 2.242

5.  Assessment of bone microarchitecture in chronic kidney disease: a comparison of 2D bone texture analysis and high-resolution peripheral quantitative computed tomography at the radius and tibia.

Authors:  Justine Bacchetta; Stéphanie Boutroy; Nicolas Vilayphiou; Anne Fouque-Aubert; Pierre D Delmas; Eric Lespessailles; Denis Fouque; Roland Chapurlat
Journal:  Calcif Tissue Int       Date:  2010-08-15       Impact factor: 4.333

6.  Predictive geometric factors in a standardized model of femoral neck fracture. Experimental study of cadaveric human femurs.

Authors:  C Kukla; C Gaebler; R W Pichl; R Prokesch; G Heinze; T Heinz
Journal:  Injury       Date:  2002-06       Impact factor: 2.586

7.  Clinical interest of bone texture analysis in osteoporosis: a case control multicenter study.

Authors:  E Lespessailles; C Gadois; I Kousignian; J P Neveu; P Fardellone; S Kolta; C Roux; J P Do-Huu; C L Benhamou
Journal:  Osteoporos Int       Date:  2008-01-15       Impact factor: 4.507

8.  Computerized radiographic analysis of osteoporosis: preliminary evaluation.

Authors:  P Caligiuri; M L Giger; M J Favus; H Jia; K Doi; L B Dixon
Journal:  Radiology       Date:  1993-02       Impact factor: 11.105

9.  Augmentation with silicone stabilizes proximal femur fractures: an in vitro biomechanical study.

Authors:  T J van der Steenhoven; W Schaasberg; A C de Vries; E R Valstar; R G H H Nelissen
Journal:  Clin Biomech (Bristol, Avon)       Date:  2009-01-24       Impact factor: 2.063

10.  Radiographic texture analysis of densitometric calcaneal images: relationship to clinical characteristics and to bone fragility.

Authors:  Tamara Vokes; Diane Lauderdale; Siu-Ling Ma; Mike Chinander; Keona Childs; Maryellen Giger
Journal:  J Bone Miner Res       Date:  2010-01       Impact factor: 6.741

View more
  6 in total

Review 1.  Clinical Evaluation of Bone Strength and Fracture Risk.

Authors:  Chantal M J de Bakker; Wei-Ju Tseng; Yihan Li; Hongbo Zhao; X Sherry Liu
Journal:  Curr Osteoporos Rep       Date:  2017-02       Impact factor: 5.096

2.  The predictive value of trabecular bone score (TBS) on whole lumbar vertebrae mechanics: an ex vivo study.

Authors:  J P Roux; J Wegrzyn; S Boutroy; M L Bouxsein; D Hans; R Chapurlat
Journal:  Osteoporos Int       Date:  2013-03-07       Impact factor: 4.507

Review 3.  Advances in bone imaging for osteoporosis.

Authors:  Judith E Adams
Journal:  Nat Rev Endocrinol       Date:  2013-01       Impact factor: 43.330

Review 4.  Are we taking full advantage of the growing number of pharmacological treatment options for osteoporosis?

Authors:  Karl J Jepsen; Stephen H Schlecht; Kenneth M Kozloff
Journal:  Curr Opin Pharmacol       Date:  2014-04-16       Impact factor: 5.547

5.  Using Magnetic Resonance for Predicting Femoral Strength: Added Value with respect to Bone Densitometry.

Authors:  Olivia Louis; Yves Fierens; Maria Strantza; Robert Luypaert; Johan de Mey; Erik Cattrysse
Journal:  Biomed Res Int       Date:  2015-08-27       Impact factor: 3.411

6.  Clinical and radiological assessment of effects of long-term corticosteroid therapy on oral health.

Authors:  Swapna Sridevi Beeraka; Kannan Natarajan; Rajendra Patil; Rakesh Kumar Manne; Venkata Sarath Prathi; Venkata Suneel Kumar Kolaparthi
Journal:  Dent Res J (Isfahan)       Date:  2013-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.