Literature DB >> 21643825

Anterior single screw fixation of odontoid fracture with intraoperative Iso-C 3-dimensional imaging.

Yong Liang Yang1, Bai Sheng Fu, Rachel W Li, Paul N Smith, Wei Dong Mu, Lian Xin Li, Dong Sheng Zhou.   

Abstract

PURPOSE: The purpose of this study was to assess the value of isocentric C-arm three-dimensional (Iso-C 3D) fluoroscopy for the insertion of an anterior odontoid screw. The results of the Iso-C 3D group were compared with that of an historic control group using conventional fluoroscopy.
METHODS: Twenty-nine patients diagnosed with type II or rostral-type III odontoid fractures were treated with a single anterior screw fixation in this study. The Iso-C 3D group included 13 patients and the other 16 patients were in the historic control group. All operations were performed by a single surgeon using standard procedure and manner. The clinical and radiographic results were recorded and compared between the two groups.
RESULTS: The fluoroscopy time in the Iso-C 3D group was 42.9 s as compared to 68.1 s in the control group (P < 0.01). The mean operative time was 91.5 min in the Iso-C 3D group when compared with 81.6 min in the control group (P = 0.20). The rate of bony fusion was 96.6% (28/29), the failure rate of reduction or fixation was 13.8% (7.7% in Iso-C 3D group; 18.8% in control group). The Smiley-Webster scale showed that 90% of patients achieved good or better outcomes
CONCLUSIONS: In conclusion, this technique can be safely extended to the treatment of technically difficult to treat spinal injuries and at the same time reduce total radiation exposure time both for the patient and the surgeon.

Entities:  

Mesh:

Year:  2011        PMID: 21643825      PMCID: PMC3207331          DOI: 10.1007/s00586-011-1860-0

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  27 in total

1.  End result study of a series of operations for herniated intervertebral lumbar discs.

Authors:  F S WEBSTER; D P SMILEY
Journal:  Am J Surg       Date:  1960-01       Impact factor: 2.565

2.  Intraoperative three-dimensional imaging with a motorized mobile C-arm (SIREMOBIL ISO-C-3D) in foot and ankle trauma care: a preliminary report.

Authors:  Martinus Richter; Jens Geerling; Stefan Zech; Thomas Goesling; Christian Krettek
Journal:  J Orthop Trauma       Date:  2005-04       Impact factor: 2.512

3.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

4.  Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery.

Authors:  Hiroaki Nakashima; Kouji Sato; Toshihiro Ando; Hidefumi Inoh; Hiroshi Nakamura
Journal:  J Spinal Disord Tech       Date:  2009-10

5.  Anatomic considerations of superior laryngeal nerve during anterior cervical spine procedures.

Authors:  Hooman Melamed; Mitchel B Harris; Deepak Awasthi
Journal:  Spine (Phila Pa 1976)       Date:  2002-02-15       Impact factor: 3.468

6.  [Screw-osteosynthesis of fractures of the dens axis (author's transl)].

Authors:  J Böhler
Journal:  Unfallheilkunde       Date:  1981-06

Review 7.  Evidence-based analysis of odontoid fracture management.

Authors:  T D Julien; B Frankel; V C Traynelis; T C Ryken
Journal:  Neurosurg Focus       Date:  2000-06-15       Impact factor: 4.047

8.  Does computer-assisted spine surgery reduce intraoperative radiation doses?

Authors:  Florian T Gebhard; Michael D Kraus; Eugen Schneider; Ulrich C Liener; Lothar Kinzl; Markus Arand
Journal:  Spine (Phila Pa 1976)       Date:  2006-08-01       Impact factor: 3.468

Review 9.  Management of acute odontoid fractures with single-screw anterior fixation.

Authors:  B R Subach; M A Morone; R W Haid; M R McLaughlin; G R Rodts; C H Comey
Journal:  Neurosurgery       Date:  1999-10       Impact factor: 4.654

10.  Operative versus nonoperative management of acute odontoid Type II fractures: a meta-analysis.

Authors:  Ali Nourbakhsh; Runhua Shi; Prasad Vannemreddy; Anil Nanda
Journal:  J Neurosurg Spine       Date:  2009-12
View more
  4 in total

Review 1.  [Intraoperative 3D imaging in spinal surgery].

Authors:  O Gonschorek; S Hauck; V Bühren
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

Review 2.  The impact of odontoid screw fixation techniques on screw-related complications and fusion rates: a systematic review and meta-analysis.

Authors:  Ivan Lvov; Andrey Grin; Aleksandr Talypov; Ivan Godkov; Anton Kordonskiy; Ulugbek Khushnazarov; Vladimir Smirnov; Vladimir Krylov
Journal:  Eur Spine J       Date:  2020-06-15       Impact factor: 3.134

3.  Biomechanical Assessment of Stabilization of Simulated Type II Odontoid Fracture with Case Study.

Authors:  Roy T Daniel; Mir M Hussain; Noelle Klocke; Soumya S Yandamuri; Lukas Bobinski; John M Duff; Brandon S Bucklen
Journal:  Asian Spine J       Date:  2017-02-17

4.  Pooled analysis of non-union, re-operation, infection, and approach related complications after anterior odontoid screw fixation.

Authors:  Nai-Feng Tian; Xu-Qi Hu; Li-Jun Wu; Xin-Lei Wu; Yao-Sen Wu; Xiao-Lei Zhang; Xiang-Yang Wang; Yong-Long Chi; Fang-Min Mao
Journal:  PLoS One       Date:  2014-07-24       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.