Literature DB >> 21619932

Practical performance evaluation of a 10k × 10k CCD for electron cryo-microscopy.

Benjamin E Bammes1, Ryan H Rochat, Joanita Jakana, Wah Chiu.   

Abstract

Electron cryo-microscopy (cryo-EM) images are commonly collected using either charge-coupled devices (CCD) or photographic film. Both film and the current generation of 16 megapixel (4k × 4k) CCD cameras have yielded high-resolution structures. Yet, despite the many advantages of CCD cameras, more than two times as many structures of biological macromolecules have been published in recent years using photographic film. The continued preference to film, especially for subnanometer-resolution structures, may be partially influenced by the finer sampling and larger effective specimen imaging area offered by film. Large format digital cameras may finally allow them to overtake film as the preferred detector for cryo-EM. We have evaluated a 111-megapixel (10k × 10k) CCD camera with a 9 μm pixel size. The spectral signal-to-noise ratios of low dose images of carbon film indicate that this detector is capable of providing signal up to at least 2/5 Nyquist frequency potentially retrievable for 3D reconstructions of biological specimens, resulting in more than double the effective specimen imaging area of existing 4k × 4k CCD cameras. We verified our estimates using frozen-hydrated ε15 bacteriophage as a biological test specimen with previously determined structure, yielding a ∼7 Å resolution single particle reconstruction from only 80 CCD frames. Finally, we explored the limits of current CCD technology by comparing the performance of this detector to various CCD cameras used for recording data yielding subnanometer resolution cryo-EM structures submitted to the electron microscopy data bank (http://www.emdatabank.org/).
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21619932      PMCID: PMC3150461          DOI: 10.1016/j.jsb.2011.05.012

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  28 in total

1.  EMAN: semiautomated software for high-resolution single-particle reconstructions.

Authors:  S J Ludtke; P R Baldwin; W Chiu
Journal:  J Struct Biol       Date:  1999-12-01       Impact factor: 2.867

2.  Characterisation of the signal and noise transfer of CCD cameras for electron detection.

Authors:  R R Meyer; A I Kirkland
Journal:  Microsc Res Tech       Date:  2000-05-01       Impact factor: 2.769

Review 3.  CCD detectors in high-resolution biological electron microscopy.

Authors:  A R Faruqi; S Subramaniam
Journal:  Q Rev Biophys       Date:  2000-02       Impact factor: 5.318

4.  Optimal determination of particle orientation, absolute hand, and contrast loss in single-particle electron cryomicroscopy.

Authors:  Peter B Rosenthal; Richard Henderson
Journal:  J Mol Biol       Date:  2003-10-31       Impact factor: 5.469

5.  Assessing the capabilities of a 4kx4k CCD camera for electron cryo-microscopy at 300kV.

Authors:  Christopher R Booth; Joanita Jakana; Wah Chiu
Journal:  J Struct Biol       Date:  2006-09-22       Impact factor: 2.867

6.  2dx--user-friendly image processing for 2D crystals.

Authors:  Bryant Gipson; Xiangyan Zeng; Zi Yan Zhang; Henning Stahlberg
Journal:  J Struct Biol       Date:  2006-09-01       Impact factor: 2.867

7.  Achievable resolution from images of biological specimens acquired from a 4k x 4k CCD camera in a 300-kV electron cryomicroscope.

Authors:  Dong-Hua Chen; Joanita Jakana; Xiangan Liu; Michael F Schmid; Wah Chiu
Journal:  J Struct Biol       Date:  2008-04-14       Impact factor: 2.867

8.  Applications of a slow-scan CCD camera in protein electron crystallography.

Authors:  J Brink; W Chiu
Journal:  J Struct Biol       Date:  1994 Jul-Aug       Impact factor: 2.867

9.  Structure of epsilon15 bacteriophage reveals genome organization and DNA packaging/injection apparatus.

Authors:  Wen Jiang; Juan Chang; Joanita Jakana; Peter Weigele; Jonathan King; Wah Chiu
Journal:  Nature       Date:  2006-02-02       Impact factor: 49.962

10.  JADAS: a customizable automated data acquisition system and its application to ice-embedded single particles.

Authors:  Junjie Zhang; Natsuko Nakamura; Yuko Shimizu; Nathan Liang; Xiangan Liu; Joanita Jakana; Michael P Marsh; Christopher R Booth; Takao Shinkawa; Munetaka Nakata; Wah Chiu
Journal:  J Struct Biol       Date:  2008-09-30       Impact factor: 2.867

View more
  7 in total

1.  Resolution and Probabilistic Models of Components in CryoEM Maps of Mature P22 Bacteriophage.

Authors:  Grigore Pintilie; Dong-Hua Chen; Cameron A Haase-Pettingell; Jonathan A King; Wah Chiu
Journal:  Biophys J       Date:  2015-12-30       Impact factor: 4.033

2.  Direct electron detection yields cryo-EM reconstructions at resolutions beyond 3/4 Nyquist frequency.

Authors:  Benjamin E Bammes; Ryan H Rochat; Joanita Jakana; Dong-Hua Chen; Wah Chiu
Journal:  J Struct Biol       Date:  2012-01-21       Impact factor: 2.867

3.  CTER-rapid estimation of CTF parameters with error assessment.

Authors:  Pawel A Penczek; Jia Fang; Xueming Li; Yifan Cheng; Justus Loerke; Christian M T Spahn
Journal:  Ultramicroscopy       Date:  2014-02-07       Impact factor: 2.689

4.  Direct Detection Electron Energy-Loss Spectroscopy: A Method to Push the Limits of Resolution and Sensitivity.

Authors:  James L Hart; Andrew C Lang; Asher C Leff; Paolo Longo; Colin Trevor; Ray D Twesten; Mitra L Taheri
Journal:  Sci Rep       Date:  2017-08-15       Impact factor: 4.379

Review 5.  The impact of recent improvements in cryo-electron microscopy technology on the understanding of bacterial ribosome assembly.

Authors:  Aida Razi; Robert A Britton; Joaquin Ortega
Journal:  Nucleic Acids Res       Date:  2017-02-17       Impact factor: 16.971

6.  Quantitative characterization of electron detectors for transmission electron microscopy.

Authors:  Rachel S Ruskin; Zhiheng Yu; Nikolaus Grigorieff
Journal:  J Struct Biol       Date:  2013-11-01       Impact factor: 2.867

Review 7.  Cryo electron microscopy to determine the structure of macromolecular complexes.

Authors:  Marta Carroni; Helen R Saibil
Journal:  Methods       Date:  2015-11-27       Impact factor: 3.608

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.