Literature DB >> 21615446

Corneal biomechanical properties measured with the Ocular Response Analyser in a myopic population.

Athina Plakitsi1, Clare O'Donnell, Marco A Miranda, W Neil Charman, Hema Radhakrishnan.   

Abstract

PURPOSE: To explore the possible association between myopia and corneal biomechanical properties in a Caucasian population, and the correlations between the properties of right and left eyes.
METHODS: Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured using the Ocular Response Analyser (ORA) in both eyes of 95 normal adult subjects aged between 19 and 48 years. The spherical equivalent refractive errors of the participants ranged from 0.25 to -14.00 D. The mean CH and CRF values for the right and left eyes were recorded for each subject. CH and CRF data were compared between different refractive groups.
RESULTS: CH was found to be slightly lower in high myopes (>-6.00 D, mean CH 10.0 ± 1.2 mmHg) in comparison to moderate myopes (>-3.00 to -6.00 D, 10.1 ± 1.4 mmHg) and emmetropes and low myopes (+0.25 to -2.75 D, 10.9 ± 1.5 mmHg). The decrease in CH with the degree of myopia was about 0.13 mmHg per D or roughly 1% per D (r(2) = 0.084, p < 0.001). Inter-subject variations were much greater than any systematic changes. CRF was not correlated with refractive error (r(2) = 0.001, p = 0.66). Although the refractive error was highly correlated between the two eyes (r(2) = 0.89, p < 0.001), CH and CRF showed a lower inter-ocular correlation (r(2) = 0.68, p < 0.001 and r(2) = 0.77, p < 0.001 respectively).
CONCLUSIONS: These findings may indicate that the viscoelastic properties of the cornea are altered to a minor extent in myopia. However, in this normal population, any overall systematic changes in CH and CRF with refractive error were small in comparison with the considerable inter-subject scatter at any level of refraction. Ophthalmic & Physiological Optics
© 2011 The College of Optometrists.

Entities:  

Mesh:

Year:  2011        PMID: 21615446     DOI: 10.1111/j.1475-1313.2011.00852.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  15 in total

1.  [Influence of corneal biomechanical properties on myopic regression after laser in situ keratomileusis].

Authors:  D Uthoff; K Hebestedt; G I W Duncker; E Spörl
Journal:  Ophthalmologe       Date:  2013-01       Impact factor: 1.059

2.  Relationships between central and peripheral corneal thickness in different degrees of myopia.

Authors:  Sara Ortiz; Laura Mena; Ana Rio-San Cristobal; Raul Martin
Journal:  J Optom       Date:  2013-05-16

3.  The Correlation Analysis between Corneal Biomechanical Properties and the Surgically Induced Corneal High-Order Aberrations after Small Incision Lenticule Extraction and Femtosecond Laser In Situ Keratomileusis.

Authors:  Wenjing Wu; Yan Wang
Journal:  J Ophthalmol       Date:  2015-09-21       Impact factor: 1.909

4.  Assessment of corneal biomechanical properties and intraocular pressure in myopic spanish healthy population.

Authors:  María A Del Buey; Laura Lavilla; Francisco J Ascaso; Elena Lanchares; Valentín Huerva; José A Cristóbal
Journal:  J Ophthalmol       Date:  2014-02-25       Impact factor: 1.909

5.  Preliminary Investigation of the Mechanical Anisotropy of the Normal Human Corneal Stroma.

Authors:  Chao Xue; Yaoqi Xiang; Min Shen; Di Wu; Yan Wang
Journal:  J Ophthalmol       Date:  2018-10-17       Impact factor: 1.909

Review 6.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

7.  Corneal Biomechanics Determination in Healthy Myopic Subjects.

Authors:  Kunliang Qiu; Xuehui Lu; Riping Zhang; Geng Wang; Mingzhi Zhang
Journal:  J Ophthalmol       Date:  2016-07-21       Impact factor: 1.909

8.  Corneal Biomechanical Properties in Myopic Eyes Measured by a Dynamic Scheimpflug Analyzer.

Authors:  Jingyi Wang; Ying Li; Yumei Jin; Xue Yang; Chan Zhao; Qin Long
Journal:  J Ophthalmol       Date:  2015-10-20       Impact factor: 1.909

9.  Impact of Myopia on Corneal Biomechanics in Glaucoma and Nonglaucoma Patients.

Authors:  Sunee Chansangpetch; Rawiphan Panpruk; Anita Manassakorn; Visanee Tantisevi; Prin Rojanapongpun; Cameron P Hurst; Shan C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2017-10-01       Impact factor: 4.799

10.  Corneal Biomechanical Properties of Keratoconic Eyes Following Penetrating Keratoplasty.

Authors:  Hamidu Gobeka; Özlem Barut Selver; Melis Palamar Onay; Sait Eğrilmez; Ayşe Yağcı
Journal:  Turk J Ophthalmol       Date:  2018-09-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.