Chao Xue1, Yaoqi Xiang2, Min Shen2, Di Wu1, Yan Wang1.
Abstract
PURPOSE: To investigate the anisotropic characteristics of the normal human corneal stroma using fresh corneal tissue.Entities:
Year: 2018 PMID: 30416826 PMCID: PMC6207891 DOI: 10.1155/2018/5392041
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Figure 1Sketch map of corneal specimen in different directions: (a) vertical; (b) horizontal.
Figure 2The stress-strain curve of a corneal strip.
Figure 3Stress-strain curves of 32 specimens in different directions: (a) vertical; (b) horizontal.
Figure 4Average stress-strain curves of specimens.
Values of constants A and B.
| No. |
|
| ||
|---|---|---|---|---|
| Vertical (MPa) | Horizontal (MPa) | Vertical | Horizontal | |
| 1 | 0.15 | 0.184 | 18.958 | 17.644 |
| 2 | 0.140 | 0.063 | 19.333 | 20.549 |
| 3 | 0.030 | 0.258 | 22.632 | 16.445 |
| 4 | 0.042 | 0.0720 | 22.771 | 20.021 |
| 5 | 0.132 | 0.063 | 18.23 | 21.219 |
| 6 | 0.075 | 0.075 | 19.502 | 18.987 |
| 7 | 0.114 | 0.139 | 19.331 | 17.604 |
| 8 | 0.222 | 0.127 | 17.548 | 17.683 |
| 9 | 0.215 | 0.369 | 17.533 | 14.288 |
| 10 | 0.276 | 0.238 | 15.732 | 15.774 |
| 11 | 0.122 | 0.135 | 19.084 | 17.432 |
| 12 | 0.119 | 0.119 | 19.516 | 17.446 |
| 13 | 0.086 | 0.0773 | 18.463 | 18.689 |
| 14 | 0.156 | 0.168 | 18.388 | 18.002 |
| 15 | 0.090 | 0.113 | 20.488 | 18.708 |
| 16 | 0.171 | 0.100 | 17.972 | 19.108 |
| 17 | 0.152 | 0.088 | 19.142 | 20.281 |
| 18 | 0.211 | 0.222 | 16.048 | 15.459 |
| 19 | 0.056 | 0.119 | 20.381 | 17.939 |
| 20 | 0.076 | 0.085 | 20.536 | 19.668 |
| 21 | 0.126 | 0.082 | 17.993 | 18.369 |
| 22 | 0.132 | 0.058 | 18.746 | 19.956 |
| 23 | 0.083 | 0.083 | 18.812 | 20.179 |
| 24 | 0.131 | 0.060 | 19.302 | 21.107 |
| 25 | 0.103 | 0.049 | 19.023 | 21.189 |
| 26 | 0.144 | 0.128 | 17.959 | 18.332 |
| 27 | 0.472 | 0.172 | 14.969 | 17.799 |
| 28 | 0.129 | 0.101 | 18.256 | 18.586 |
| 29 | 0.094 | 0.211 | 19.039 | 16.713 |
| 30 | 0.126 | 0.133 | 18.438 | 17.57 |
| 31 | 0.183 | 0.511 | 17.078 | 14.302 |
| 32 | 0.108 | 0.064 | 19.634 | 19.178 |
| Mean ± SD | 0.140 ± 0.08 | 0.140 ± 0.10 | 18.78 ± 1.63 | 18.32 ± 1.83 |
Figure 5Curve fitting to obtain Young's modulus.
Comparison of LSTM and HSTM in eye pairs.
| Parameters | Horizontal | Vertical |
|
|---|---|---|---|
| LSTM(MPa) | 1.17 ± 0.43 | 1.32 ± 0.50 | 0.035 |
| HSTM(MPa) | 43.59 ± 7.96 | 51.26 ± 8.23 | ≤0.001 |
Figure 6Relationships between elastic modulus and stress.
Comparison of elastic modulus at different stress levels.
| Stress (MPa) | Vertical (MPa) | Horizontal (MPa) |
|
|---|---|---|---|
| 0.01 | 1.28 ± 0.70 | 1.17 ± 0.50 | 0.338 |
| 0.02 | 1.57 ± 0.67 | 1.46 ± 0.47 | 0.373 |
| 0.03 | 1.84 ± 0.64 | 1.75 ± 0.45 | 0.417 |