Evaluation of the effect of force direction on stationary anchorage success of mini-implant with a lever-arm-shaped upper structure.

Ki-Ho Park1, Eun-Man Lee, Seung-Il Shin, Seong-Hun Kim, Young-Guk Park, Su-Jung Kim.   

Abstract

OBJECTIVE: To compare the effect of clockwise and counterclockwise torque on the primary stability of a mini-implant with a lever-arm-shaped upper structure.
MATERIALS AND METHODS: Twenty-four white rabbits were used for this study. Two screw-type mini-implants were placed in each tibia. In all, 96 screws were inserted. Two weeks later, a 2-N force was applied to the mini-implants without an upper structure in eight rabbits (control group). The mini-implants of the other 16 rabbits were loaded with an upper structure (experimental group). In the experimental group, the two left mini-implants were loaded in a clockwise direction (CW group) and the two right implants were loaded in a counterclockwise direction (CCW group). The rabbits were sacrificed at 1 week or 8 weeks after loading in both control and experimental groups. The removal torque value (RTV) was measured in 15 of 16 mini-implants in each group and the remaining implant was processed for histologic examination.
RESULTS: At 1 week there were no significant differences in the mean RTV between the control, CW, and CCW groups. At 8 weeks, the RTV was higher in the control and experimental groups than in the respective 1-week groups. At 8 weeks, there were no significant differences in the RTV between the control and CW groups, but the CCW group showed a lower RTV.
CONCLUSIONS: CCW torque can decrease the stability of a mini-implant, whereas a CW torque has no effect.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21615210      PMCID: PMC8916180          DOI: 10.2319/092810-566.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  18 in total

1.  The use of small titanium screws for orthodontic anchorage.

Authors:  T Deguchi; T Takano-Yamamoto; R Kanomi; J K Hartsfield; W E Roberts; L P Garetto
Journal:  J Dent Res       Date:  2003-05       Impact factor: 6.116

2.  Rigid endosseous implants for orthodontic and orthopedic anchorage.

Authors:  W E Roberts; F R Helm; K J Marshall; R K Gongloff
Journal:  Angle Orthod       Date:  1989       Impact factor: 2.079

3.  Immediate loading of modular transitional implants: a histologic and histomorphometric study in dogs.

Authors:  Y Zubery; N Bichacho; O Moses; H Tal
Journal:  Int J Periodontics Restorative Dent       Date:  1999-08       Impact factor: 1.840

4.  Load-related implant reaction of mini-implants used for orthodontic anchorage.

Authors:  André Büchter; Dirk Wiechmann; Stefan Koerdt; Hans Peter Wiesmann; Josef Piffko; Ulrich Meyer
Journal:  Clin Oral Implants Res       Date:  2005-08       Impact factor: 5.977

5.  Orthodontic force application to titanium endosseous implants.

Authors:  P K Turley; C Kean; J Schur; J Stefanac; J Gray; J Hennes; L C Poon
Journal:  Angle Orthod       Date:  1988-04       Impact factor: 2.079

6.  Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs.

Authors:  Sarandeep S Huja; Alan S Litsky; F Mike Beck; Kenneth A Johnson; Peter E Larsen
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-03       Impact factor: 2.650

7.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.

Authors:  R Adell; U Lekholm; B Rockler; P I Brånemark
Journal:  Int J Oral Surg       Date:  1981-12

8.  Bone response to orthodontic loading of endosseous implants in the rabbit calvaria: early continuous distalizing forces.

Authors:  Z Majzoub; M Finotti; F Miotti; R Giardino; N N Aldini; G Cordioli
Journal:  Eur J Orthod       Date:  1999-06       Impact factor: 3.075

9.  Endosseous titanium implants as anchors for mesiodistal tooth movement in the beagle dog.

Authors:  S Saito; N Sugimoto; T Morohashi; M Ozeki; H Kurabayashi; H Shimizu; K Yamasaki; A Shiba; S Yamada; Y Shibasaki
Journal:  Am J Orthod Dentofacial Orthop       Date:  2000-12       Impact factor: 2.650

10.  Miniscrews as orthodontic anchorage: a preliminary report.

Authors:  A Costa; M Raffainl; B Melsen
Journal:  Int J Adult Orthodon Orthognath Surg       Date:  1998
View more
  1 in total

1.  Direct versus indirect loading of orthodontic miniscrew implants-an FEM analysis.

Authors:  C Holberg; P Winterhalder; N Holberg; I Rudzki-Janson; A Wichelhaus
Journal:  Clin Oral Investig       Date:  2012-10-31       Impact factor: 3.573

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.