Implant stability is affected by local bone microstructural quality.

Andreas J Wirth1, Jörg Goldhahn, Cyril Flaig, Peter Arbenz, Ralph Müller, G Harry van Lenthe.   

Abstract

It is known that low bone quality, caused for instance by osteoporosis, not only increases the risk of fractures, but also decreases the performance of fracture implants; yet the specific mechanisms behind this phenomenon are still largely unknown. We hypothesized that especially peri-implant bone microstructure affects implant stability in trabecular bone, to a greater degree than more distant bone. To test this hypothesis we performed a computational study on implant stability in trabecular bone. Twelve humeral heads were measured using micro-computed tomography. Screws were inserted digitally into these heads at 25 positions. In addition, at each screw location, a virtual biopsy was taken. Bone structural quality was quantified by morphometric parameters. The stiffness of the 300 screw-bone constructs was quantified as a measure of implant stability. Global bone density correlated moderately with screw-bone stiffness (r2=0.52), whereas local bone density was a very good predictor (r2=0.91). The best correlation with screw-bone stiffness was found for local bone apparent Young's modulus (r2=0.97), revealing that not only bone mass but also its arrangement in the trabecular microarchitecture are important for implant stability. In conclusion, we confirmed our hypothesis that implant stability is affected by the microstructural bone quality of the trabecular bone in the direct vicinity of the implant. Local bone density was the best single morphometric predictor of implant stability. The best predictability was provided by the mechanical competence of the peri-implant bone. A clinical implication of this work is that apparently good bone stock, such as assessed by DXA, does not guarantee good local bone quality, and hence does not guarantee good implant stability. New tools that could quantify the structural or mechanical quality of the peri-implant bone may help improve the surgical intervention in reaching better clinical outcomes for screw fixation.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21609793     DOI: 10.1016/j.bone.2011.05.001

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  10 in total

1.  Comparison of mandibular bone microarchitecture between micro-CT and CBCT images.

Authors:  S Panmekiate; N Ngonphloy; T Charoenkarn; T Faruangsaeng; R Pauwels
Journal:  Dentomaxillofac Radiol       Date:  2015-01-07       Impact factor: 2.419

Review 2.  Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

3.  Effect of exposure parameters and voxel size on bone structure analysis in CBCT.

Authors:  R Pauwels; T Faruangsaeng; T Charoenkarn; N Ngonphloy; S Panmekiate
Journal:  Dentomaxillofac Radiol       Date:  2015-06-09       Impact factor: 2.419

4.  Intermittent PTH administration and mechanical loading are anabolic for periprosthetic cancellous bone.

Authors:  Matthew J Grosso; Hayden-William Courtland; Xu Yang; James P Sutherland; Kirsten Stoner; Joseph Nguyen; Anna Fahlgren; F Patrick Ross; Marjolein C H van der Meulen; Mathias P Bostrom
Journal:  J Orthop Res       Date:  2014-11-18       Impact factor: 3.494

5.  Is trabecular bone related to primary stability of miniscrews?

Authors:  Mariana Marquezan; Inayá Lima; Ricardo Tadeu Lopes; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza
Journal:  Angle Orthod       Date:  2013-11-18       Impact factor: 2.079

6.  Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT.

Authors:  Norliza Ibrahim; Azin Parsa; Bassam Hassan; Paul van der Stelt; Rabiah A Rahmat; Siti M Ismail; Irene H A Aartman
Journal:  BMC Oral Health       Date:  2021-05-08       Impact factor: 2.757

7.  Single-dose local simvastatin injection improves implant fixation via increased angiogenesis and bone formation in an ovariectomized rat model.

Authors:  Jie Tan; Ning Yang; Xin Fu; Yueyi Cui; Qi Guo; Teng Ma; Xiaoxue Yin; Huijie Leng; Chunli Song
Journal:  Med Sci Monit       Date:  2015-05-18

Review 8.  The Applications of Finite Element Analysis in Proximal Humeral Fractures.

Authors:  Yongyu Ye; Wei You; Weimin Zhu; Jiaming Cui; Kang Chen; Daping Wang
Journal:  Comput Math Methods Med       Date:  2017-09-10       Impact factor: 2.238

9.  Spatial mapping of humeral head bone density.

Authors:  Hamidreza Alidousti; Joshua W Giles; Roger J H Emery; Jonathan Jeffers
Journal:  J Shoulder Elbow Surg       Date:  2017-05-08       Impact factor: 3.019

Review 10.  Finite Element Analysis of Fracture Fixation.

Authors:  Gregory S Lewis; Dominic Mischler; Hwabok Wee; J Spence Reid; Peter Varga
Journal:  Curr Osteoporos Rep       Date:  2021-06-29       Impact factor: 5.163

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.