BACKGROUND: Radiographic evaluation has a prominent place in the follow-up of long-term results of uncemented total hip arthroplasty (THA). The most prominent scale reported in studies is the Engh Grading Scale, but there is a lack of literature on the reliability of the scale. METHODS: We evaluated intra- and interrater reliability of the Engh Grading System for uncemented THA using 26 follow-up radiographs of patients who had primary uncemented THAs. Four evaluators with different skill levels and specialties participated: 2 arthroplasty surgeons, an orthopedic resident and a radiologist. Reliability was measured using a weighted κ coefficient for paired comparisons among the evaluators. RESULTS: Intrarater reliability was dependent on the skill and specialty of the evaluator, with the highest values achieved for the arthroplasty surgeons (κ = 0.52 and κ = 0.68) and the lowest values for the radiologist (κ = 0.14). Interrater reliability was comparable among participants, regardless of skill or specialty, and rated a moderate level of reliability (κ = 0.29-0.41) for all pairings. CONCLUSION: The Engh Grading Scale appears to be reliable when used by a single, experienced arthroplasty surgeon. Caution must be exercised when multiple raters are used, regardless of experience, as the interrater reliability achieved lower ratings.
BACKGROUND: Radiographic evaluation has a prominent place in the follow-up of long-term results of uncemented total hip arthroplasty (THA). The most prominent scale reported in studies is the Engh Grading Scale, but there is a lack of literature on the reliability of the scale. METHODS: We evaluated intra- and interrater reliability of the Engh Grading System for uncemented THA using 26 follow-up radiographs of patients who had primary uncemented THAs. Four evaluators with different skill levels and specialties participated: 2 arthroplasty surgeons, an orthopedic resident and a radiologist. Reliability was measured using a weighted κ coefficient for paired comparisons among the evaluators. RESULTS: Intrarater reliability was dependent on the skill and specialty of the evaluator, with the highest values achieved for the arthroplasty surgeons (κ = 0.52 and κ = 0.68) and the lowest values for the radiologist (κ = 0.14). Interrater reliability was comparable among participants, regardless of skill or specialty, and rated a moderate level of reliability (κ = 0.29-0.41) for all pairings. CONCLUSION: The Engh Grading Scale appears to be reliable when used by a single, experienced arthroplasty surgeon. Caution must be exercised when multiple raters are used, regardless of experience, as the interrater reliability achieved lower ratings.
Authors: John C Clohisy; Ganesh V Kamath; Gregory D Byrd; Karen Steger-May; Rick W Wright Journal: J Bone Joint Surg Am Date: 2008-09 Impact factor: 5.284
Authors: Rens Bexkens; Femke M A P Claessen; Izaäk F Kodde; Luke S Oh; Denise Eygendaal; Michel P J van den Bekerom Journal: Shoulder Elbow Date: 2017-07-10