Literature DB >> 33427897

Short stem total hip arthroplasty with the direct anterior approach demonstrates suboptimal fixation.

Guido Garavaglia1, Amanda Gonzalez2, Christophe Barea2, Robin Peter2, Pierre Hoffmeyer2, Anne Lübbeke2, Didier Hannouche2.   

Abstract

PURPOSE: Short stems use has increased substantially despite variable results reported in the literature. The purpose of this study was to report the rate of complications using a short stem implanted through the direct anterior approach (DAA), and to evaluate mid-term clinical and radiological results focusing on femoral stem fixation.
METHODS: Between April 2009 and November 2014, 698 elective total hip arthroplasties (THAs) were performed using a fully hydroxyapatite-coated short stem (AMIStem-H®). The mean age was 65.7 years (SD 12.6). Patients were invited for clinical and radiological evaluation, and to complete patient-reported outcomes questionnaires at two and five years after surgery. The mean follow-up was 6.2 years (range 2-9.73 years).
RESULTS: During the study period, 59 (8.5%) patients died and 24 (3.4%) were lost to follow-up. There were six (0.9%) dislocations and 12 (1.7%) fractures, seven occurred intra-operatively. Twenty-nine (4.2%) THAs required revision surgery. Eleven THAs were revised for aseptic loosening of the stem at a mean 4.9 years (1.2-7.3 years). Five years after surgery, radiographs of 324 THAs (324/425 eligible = 76.2%) were available. Stem subsidence ≥ 2 mm was present in 42 cases (12.9%), proximal radiolucencies in 101 hips (31.5%), cortical thickening in 52 (16.0%), and a pedestal in 219 (67.6%). An Engh score between - 10 and 0 was associated with lower HHS pain subscore (p = 0.005), a higher risk of stem revision for aseptic loosening (18.8% vs. 2.7%; p = 0.008), and was more frequent in younger patients with ASA score 1.
CONCLUSION: Patients presenting radiological alterations at five years had an increased risk of revision for aseptic stem loosening and also inferior clinical results. Our study warrants further continued scrutiny of mid- and long-term survivorship of the AMIStem-H®, with radiological results at five years indicating suboptimal fixation of the stem in younger and active patients.

Entities:  

Keywords:  Complications; Loosening; Short stem; Total hip arthroplasty

Year:  2021        PMID: 33427897      PMCID: PMC7892742          DOI: 10.1007/s00264-020-04910-5

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  23 in total

1.  Does the Canal Fill Ratio and Femoral Morphology of Asian Females Influence Early Radiographic Outcomes of Total Hip Arthroplasty With an Uncemented Proximally Coated, Tapered-Wedge Stem?

Authors:  Seiya Ishii; Yasuhiro Homma; Tomonori Baba; Yu Ozaki; Mikio Matsumoto; Kazuo Kaneko
Journal:  J Arthroplasty       Date:  2016-01-21       Impact factor: 4.757

2.  Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components.

Authors:  C A Engh; P Massin; K E Suthers
Journal:  Clin Orthop Relat Res       Date:  1990-08       Impact factor: 4.176

3.  Patient-reported outcomes in the Swedish Hip Arthroplasty Register: results of a nationwide prospective observational study.

Authors:  O Rolfson; J Kärrholm; L E Dahlberg; G Garellick
Journal:  J Bone Joint Surg Br       Date:  2011-07

Review 4.  Cementless femoral stem fixation and leg-length discrepancy after total hip arthroplasty in different proximal femoral morphological types.

Authors:  Blaž Mavčič; Vane Antolič
Journal:  Int Orthop       Date:  2020-06-22       Impact factor: 3.075

5.  Structural and cellular assessment of bone quality of proximal femur.

Authors:  L D Dorr; M C Faugere; A M Mackel; T A Gruen; B Bognar; H H Malluche
Journal:  Bone       Date:  1993 May-Jun       Impact factor: 4.398

6.  Radiographic assessment of uncemented total hip arthroplasty: reliability of the Engh Grading Scale.

Authors:  Susan W Muir; Aziz Al-Ahaideb; John Huckell; Mary Ann Johnson; D Bill C Johnston; Lauren A Beaupre
Journal:  Can J Surg       Date:  2011-06       Impact factor: 2.089

7.  Patient-related risk factors leading to aseptic stem loosening in total hip arthroplasty: a case-control study of 5,035 patients.

Authors:  Peter Münger; Christoph Röder; Ursula Ackermann-Liebrich; André Busato
Journal:  Acta Orthop       Date:  2006-08       Impact factor: 3.717

8.  Mini-incision anterior approach does not increase dislocation rate: a study of 1037 total hip replacements.

Authors:  Thierry Siguier; Marc Siguier; Bertrand Brumpt
Journal:  Clin Orthop Relat Res       Date:  2004-09       Impact factor: 4.176

9.  Cortical hypertrophy with a short, curved uncemented hip stem does not have any clinical impact during early follow-up.

Authors:  Michael W Maier; Marcus R Streit; Moritz M Innmann; Marlis Krüger; Jan Nadorf; J Philippe Kretzer; Volker Ewerbeck; Tobias Gotterbarm
Journal:  BMC Musculoskelet Disord       Date:  2015-12-01       Impact factor: 2.362

10.  Influence of femoral morphology and canal fill ratio on early radiological and clinical outcomes of uncemented total hip arthroplasty using a fully coated stem.

Authors:  Adrien D'Ambrosio; Lisa Peduzzi; Olivier Roche; Hugo Bothorel; Mo Saffarini; François Bonnomet
Journal:  Bone Joint Res       Date:  2020-05-16       Impact factor: 5.853

View more
  1 in total

1.  5-Year Clinical and Radiographic Results of the Direct Anterior Approach for Total Hip Arthroplasty Using a Collared Cementless Femoral Short-Stem Prosthesis.

Authors:  Ali Darwich; Kim Pankert; Andreas Ottersbach; Marcel Betsch; Sascha Gravius; Mohamad Bdeir
Journal:  J Clin Med       Date:  2022-01-11       Impact factor: 4.241

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.