Literature DB >> 21607117

Studies of RF Shimming Techniques with Minimization of RF Power Deposition and Their Associated Temperature Changes.

Lin Tang1, Yik-Kiong Hue, Tamer S Ibrahim.   

Abstract

In ultrahigh field (UHF), human magnetic resonance imaging (MRI) concerns related to the homogeneity of the B1+ field [the radiofrequency (RF) magnetic field component responsible for the excitation of the spins] and the local/average specific absorption rate (SAR) are highly evident. In this work, through RF shimming techniques, a full-wave electromagnetic model that treats a coupled-RF coil and the load (an 18-tissue anatomically detailed human head model) as a single system is utilized to simultaneously (1) improve the homogeneity of B1+ field in various regions of interest across the volume of the human head and (2) minimize the total RF power deposition at 7 and 9.4 T. The numerical results illustrate that the B1+ field homogeneity (evaluated by the coefficient of variance) can be greatly improved in 3D slabs that vary in orientations and sizes, in the brain, and in the entire head volume without increasing the total RF power deposition in the head to exceed that obtained with quadrature excitation. The RF shimming simulation results are experimentally validated (by performing RF shimming without experimental B(1) measurements) on a head-sized phantom using a 7-T human MRI scanner equipped with a transmit array excitation system. The SAR and associated temperature changes under quadrature and RF shimming excitation conditions are calculated and compared.

Entities:  

Year:  2011        PMID: 21607117      PMCID: PMC3098508          DOI: 10.1002/cmr.b.20185

Source DB:  PubMed          Journal:  Concepts Magn Reson Part B Magn Reson Eng        ISSN: 1552-5031            Impact factor:   1.176


  43 in total

1.  Electromagnetic and thermal modeling of SAR and temperature fields in tissue due to an RF decoupling coil.

Authors:  J W Hand; R W Lau; J J Lagendijk; J Ling; M Burl; I R Young
Journal:  Magn Reson Med       Date:  1999-07       Impact factor: 4.668

2.  Analysis of B1 field profiles and SAR values for multi-strut transverse electromagnetic RF coils in high field MRI applications.

Authors:  T S Ibrahim; A M Abduljalil; B A Baertlein; R Lee; P M Robitaill
Journal:  Phys Med Biol       Date:  2001-10       Impact factor: 3.609

3.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

4.  Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla.

Authors:  Tamer S Ibrahim; Chad Mitchell; Petra Schmalbrock; Robert Lee; Donald W Chakeres
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

5.  Proposed radiofrequency phased-array excitation scheme for homogenous and localized 7-Tesla whole-body imaging based on full-wave numerical simulations.

Authors:  Roney Abraham; Tamer S Ibrahim
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

6.  SAR and temperature: simulations and comparison to regulatory limits for MRI.

Authors:  Zhangwei Wang; James C Lin; Weihua Mao; Wanzhan Liu; Michael B Smith; Christopher M Collins
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

7.  Numerical simulation of SAR and B1-field inhomogeneity of shielded RF coils loaded with the human head.

Authors:  J Chen; Z Feng; J M Jin
Journal:  IEEE Trans Biomed Eng       Date:  1998-05       Impact factor: 4.538

8.  The field dependence of NMR imaging. I. Laboratory assessment of signal-to-noise ratio and power deposition.

Authors:  C N Chen; V J Sank; S M Cohen; D I Hoult
Journal:  Magn Reson Med       Date:  1986-10       Impact factor: 4.668

9.  Quadrature detection in the laboratory frame.

Authors:  D I Hoult; C N Chen; V J Sank
Journal:  Magn Reson Med       Date:  1984-09       Impact factor: 4.668

10.  Slice-selective RF pulses for in vivo B1+ inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16-element coil.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Borjan Gagoski; Thomas Witzel; Jonathan Polimeni; Andreas Potthast; Franz Hebrank; Ulrich Fontius; Franz Schmitt; Lawrence L Wald; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

View more
  13 in total

1.  Multislice ¹H MRSI of the human brain at 7 T using dynamic B₀ and B₁ shimming.

Authors:  Vincent O Boer; Dennis W J Klomp; Christoph Juchem; Peter R Luijten; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  Method for in situ characterization of radiofrequency heating in parallel transmit MRI.

Authors:  Leeor Alon; Cem Murat Deniz; Ryan Brown; Daniel K Sodickson; Yudong Zhu
Journal:  Magn Reson Med       Date:  2012-06-19       Impact factor: 4.668

3.  Ultra-high-field RF coil development for evaluating upper extremity imaging applications.

Authors:  Shailesh B Raval; Tiejun Zhao; Narayanan Krishnamurthy; Tales Santini; Cynthia Britton; Vijay S Gorantla; Tamer S Ibrahim
Journal:  NMR Biomed       Date:  2016-11-03       Impact factor: 4.044

4.  Cerebral TOF angiography at 7T: Impact of B1 (+) shimming with a 16-channel transceiver array.

Authors:  Sebastian Schmitter; Xiaoping Wu; Gregor Adriany; Edward J Auerbach; Kâmil Uğurbil; Pierre-François Moortele
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

5.  Quantitative study of liver magnetic resonance spectroscopy quality at 3T using body and phased array coils with physical analysis and clinical evaluation.

Authors:  Li Xu; Shiyong Gu; Qianjin Feng; Changhong Liang; Sherman Xuegang Xin
Journal:  PLoS One       Date:  2015-04-16       Impact factor: 3.240

6.  Design and fabrication of a realistic anthropomorphic heterogeneous head phantom for MR purposes.

Authors:  Sossena Wood; Narayanan Krishnamurthy; Tales Santini; Shailesh B Raval; Nadim Farhat; John Andy Holmes; Tamer S Ibrahim
Journal:  PLoS One       Date:  2017-08-14       Impact factor: 3.240

7.  Computational and experimental evaluation of the Tic-Tac-Toe RF coil for 7 Tesla MRI.

Authors:  Narayanan Krishnamurthy; Tales Santini; Sossena Wood; Junghwan Kim; Tiejun Zhao; Howard J Aizenstein; Tamer S Ibrahim
Journal:  PLoS One       Date:  2019-01-10       Impact factor: 3.240

8.  Evaluation of a subject specific dual-transmit approach for improving B1 field homogeneity in cardiovascular magnetic resonance at 3T.

Authors:  Ramkumar Krishnamurthy; Amol Pednekar; Marc Kouwenhoven; Benjamin Cheong; Raja Muthupillai
Journal:  J Cardiovasc Magn Reson       Date:  2013-08-06       Impact factor: 5.364

9.  Implanted miniaturized antenna for brain computer interface applications: analysis and design.

Authors:  Yujuan Zhao; Robert L Rennaker; Chris Hutchens; Tamer S Ibrahim
Journal:  PLoS One       Date:  2014-07-31       Impact factor: 3.240

10.  In-vivo and numerical analysis of the eigenmodes produced by a multi-level Tic-Tac-Toe head transmit array for 7 Tesla MRI.

Authors:  Tales Santini; Yujuan Zhao; Sossena Wood; Narayanan Krishnamurthy; Junghwan Kim; Nadim Farhat; Salem Alkhateeb; Tiago Martins; Minseok Koo; Tiejun Zhao; Howard J Aizenstein; Tamer S Ibrahim
Journal:  PLoS One       Date:  2018-11-27       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.