Literature DB >> 21591003

MR elastography of human lung parenchyma: technical development, theoretical modeling and in vivo validation.

Yogesh K Mariappan1, Kevin J Glaser, Rolf D Hubmayr, Armando Manduca, Richard L Ehman, Kiaran P McGee.   

Abstract

PURPOSE: To develop a novel MR-based method for visualizing the elastic properties of human lung parenchyma in vivo and to evaluate the ability of this method to resolve differences in parenchymal stiffness at different respiration states in healthy volunteers.
MATERIALS AND METHODS: A spin-echo MR Elastography (MRE) pulse sequence was developed to provide both high shear wave motion sensitivity and short TE for improved visualization of lung parenchyma. The improved motion sensitivity of this approach was modeled and tested with phantom experiments. In vivo testing was then performed on 10 healthy volunteers at the respiratory states of residual volume (RV) and total lung capacity (TLC).
RESULTS: Shear wave propagation was visualized within the lungs of all volunteers and was processed to provide parenchymal shear stiffness maps for all 10 subjects. Density corrected stiffness values at TLC (1.83 ± 0.22 kPa) were higher than those at the RV (1.14 ± 0.14 kPa) with the difference being statistically significant (P < 0.0001).
CONCLUSION: (1)H-based MR elastography can noninvasively measure the shear stiffness of human lung parenchyma in vivo and can quantitate the change in shear stiffness due to respiration. The values obtained were consistent with previously reported in vitro assessments of cadaver lungs. Further work is required to increase the flexibility of the current acquisition and to investigate the clinical potential of lung MRE.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21591003      PMCID: PMC3098473          DOI: 10.1002/jmri.22550

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  35 in total

1.  Spatio-temporal directional filtering for improved inversion of MR elastography images.

Authors:  A Manduca; D S Lake; S A Kruse; R L Ehman
Journal:  Med Image Anal       Date:  2003-12       Impact factor: 8.545

2.  Magnetic resonance elastography of the lung: technical feasibility.

Authors:  B C Goss; K P McGee; E C Ehman; A Manduca; R L Ehman
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

3.  Magnetic resonance elastography with a phased-array acoustic driver system.

Authors:  Yogesh K Mariappan; Phillip J Rossman; Kevin J Glaser; Armando Manduca; Richard L Ehman
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

4.  Elastic constants of inflated lobes of dog lungs.

Authors:  S J Lai-Fook; T A Wilson; R E Hyatt; J R Rodarte
Journal:  J Appl Physiol       Date:  1976-04       Impact factor: 3.531

Review 5.  Reference values for residual volume, functional residual capacity and total lung capacity. ATS Workshop on Lung Volume Measurements. Official Statement of The European Respiratory Society.

Authors:  J Stocks; P H Quanjer
Journal:  Eur Respir J       Date:  1995-03       Impact factor: 16.671

6.  Magnetic resonance elastography: non-invasive mapping of tissue elasticity.

Authors:  A Manduca; T E Oliphant; M A Dresner; J L Mahowald; S A Kruse; E Amromin; J P Felmlee; J F Greenleaf; R L Ehman
Journal:  Med Image Anal       Date:  2001-12       Impact factor: 8.545

7.  MR elastography as a method for the assessment of myocardial stiffness: comparison with an established pressure-volume model in a left ventricular model of the heart.

Authors:  Arunark Kolipaka; Kiaran P McGee; Philip A Araoz; Kevin J Glaser; Armando Manduca; Anthony J Romano; Richard L Ehman
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

8.  Non-invasive measurement of brain viscoelasticity using magnetic resonance elastography.

Authors:  Ingolf Sack; Bernd Beierbach; Uwe Hamhaber; Dieter Klatt; Jürgen Braun
Journal:  NMR Biomed       Date:  2008-03       Impact factor: 4.044

9.  Feasibility of quantifying the mechanical properties of lung parenchyma in a small-animal model using (1)H magnetic resonance elastography (MRE).

Authors:  Kiaran P McGee; Rolf D Hubmayr; David Levin; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2009-04       Impact factor: 4.813

Review 10.  Lung parenchymal mechanics in health and disease.

Authors:  Débora S Faffe; Walter A Zin
Journal:  Physiol Rev       Date:  2009-07       Impact factor: 37.312

View more
  26 in total

Review 1.  General review of magnetic resonance elastography.

Authors:  Gavin Low; Scott A Kruse; David J Lomas
Journal:  World J Radiol       Date:  2016-01-28

Review 2.  Imaging for lung physiology: what do we wish we could measure?

Authors:  H Thomas Robertson; Richard B Buxton
Journal:  J Appl Physiol (1985)       Date:  2012-05-10

3.  Estimation of the absolute shear stiffness of human lung parenchyma using (1) H spin echo, echo planar MR elastography.

Authors:  Yogesh K Mariappan; Kevin J Glaser; David L Levin; Robert Vassallo; Rolf D Hubmayr; Carl Mottram; Richard L Ehman; Kiaran P McGee
Journal:  J Magn Reson Imaging       Date:  2013-11-13       Impact factor: 4.813

Review 4.  Advanced functional thoracic imaging in children: from basic concepts to clinical applications.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2013-02-16

5.  Rapid acquisition technique for MR elastography of the liver.

Authors:  Suresh K Chamarthi; Brian Raterman; Ria Mazumder; Anthony Michaels; Veeral M Oza; James Hanje; Bradley Bolster; Ning Jin; Richard D White; Arunark Kolipaka
Journal:  Magn Reson Imaging       Date:  2014-02-13       Impact factor: 2.546

6.  Quantification of myocardial stiffness using magnetic resonance elastography in right ventricular hypertrophy: initial feasibility in dogs.

Authors:  Juliana S da Silveira; Brian A Scansen; Peter A Wassenaar; Brian Raterman; Chethan Eleswarpu; Ning Jin; Xiaokui Mo; Richard D White; John D Bonagura; Arunark Kolipaka
Journal:  Magn Reson Imaging       Date:  2015-10-22       Impact factor: 2.546

7.  A multiscale analytical model of bronchial airway acoustics.

Authors:  Brian Henry; Thomas J Royston
Journal:  J Acoust Soc Am       Date:  2017-10       Impact factor: 1.840

Review 8.  Advances and Future Direction of Magnetic Resonance Elastography.

Authors:  Huiming Dong; Richard D White; Arunark Kolipaka
Journal:  Top Magn Reson Imaging       Date:  2018-10

9.  Sound transmission in porcine thorax through airway insonification.

Authors:  Ying Peng; Zoujun Dai; Hansen A Mansy; Brian M Henry; Richard H Sandler; Robert A Balk; Thomas J Royston
Journal:  Med Biol Eng Comput       Date:  2015-08-18       Impact factor: 2.602

Review 10.  Magnetic resonance elastography (MRE) in cancer: Technique, analysis, and applications.

Authors:  Kay M Pepin; Richard L Ehman; Kiaran P McGee
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2015-06-23       Impact factor: 9.795

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.