Literature DB >> 21574184

Estimation of liver T₂ in transfusion-related iron overload in patients with weighted least squares T₂ IDEAL.

Shreyas S Vasanawala1, Huanzhou Yu, Ann Shimakawa, Michael Jeng, Jean H Brittain.   

Abstract

MRI imaging of hepatic iron overload can be achieved by estimating T(2) values using multiple-echo sequences. The purpose of this work is to develop and clinically evaluate a weighted least squares algorithm based on T(2) Iterative Decomposition of water and fat with Echo Asymmetry and Least-squares estimation (IDEAL) technique for volumetric estimation of hepatic T(2) in the setting of iron overload. The weighted least squares T(2) IDEAL technique improves T(2) estimation by automatically decreasing the impact of later, noise-dominated echoes. The technique was evaluated in 37 patients with iron overload. Each patient underwent (i) a standard 2D multiple-echo gradient echo sequence for T(2) assessment with nonlinear exponential fitting, and (ii) a 3D T(2) IDEAL technique, with and without a weighted least squares fit. Regression and Bland-Altman analysis demonstrated strong correlation between conventional 2D and T(2) IDEAL estimation. In cases of severe iron overload, T(2) IDEAL without weighted least squares reconstruction resulted in a relative overestimation of T(2) compared with weighted least squares.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21574184     DOI: 10.1002/mrm.22986

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  On the confounding effect of temperature on chemical shift-encoded fat quantification.

Authors:  Diego Hernando; Samir D Sharma; Harald Kramer; Scott B Reeder
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

2.  Variations in T(2)* and fat content of murine brown and white adipose tissues by chemical-shift MRI.

Authors:  Houchun H Hu; Catherine D G Hines; Daniel L Smith; Scott B Reeder
Journal:  Magn Reson Imaging       Date:  2012-01-13       Impact factor: 2.546

3.  Resolving estimation uncertainties of chemical shift encoded fat-water imaging using magnetization transfer effect.

Authors:  Alexey Samsonov; Fang Liu; Julia V Velikina
Journal:  Magn Reson Med       Date:  2019-03-07       Impact factor: 4.668

4.  Simultaneous field and R2 mapping to quantify liver iron content using autoregressive moving average modeling.

Authors:  Brian A Taylor; Ralf B Loeffler; Ruitian Song; M Beth McCarville; Jane S Hankins; Claudia M Hillenbrand
Journal:  J Magn Reson Imaging       Date:  2011-12-16       Impact factor: 4.813

5.  Utilization of a balanced steady state free precession signal model for improved fat/water decomposition.

Authors:  Leah C Henze Bancroft; Roberta M Strigel; Diego Hernando; Kevin M Johnson; Frederick Kelcz; Richard Kijowski; Walter F Block
Journal:  Magn Reson Med       Date:  2015-05-06       Impact factor: 4.668

Review 6.  Imaging patterns of fatty liver in pediatric patients.

Authors:  H Nursun Özcan; Berna Oğuz; Mithat Haliloğlu; Diclehan Orhan; Muşturay Karçaaltıncaba
Journal:  Diagn Interv Radiol       Date:  2015 Jul-Aug       Impact factor: 2.630

7.  Free-breathing liver fat and R 2 quantification using motion-corrected averaging based on a nonlocal means algorithm.

Authors:  Huiwen Luo; Ante Zhu; Curtis N Wiens; Jitka Starekova; Ann Shimakawa; Scott B Reeder; Kevin M Johnson; Diego Hernando
Journal:  Magn Reson Med       Date:  2020-08-01       Impact factor: 4.668

Review 8.  Quantification of liver iron with MRI: state of the art and remaining challenges.

Authors:  Diego Hernando; Yakir S Levin; Claude B Sirlin; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2014-03-03       Impact factor: 4.813

9.  Multipeak fat-corrected complex R2* relaxometry: theory, optimization, and clinical validation.

Authors:  Diego Hernando; J Harald Kramer; Scott B Reeder
Journal:  Magn Reson Med       Date:  2013-01-28       Impact factor: 4.668

10.  Does fat suppression via chemically selective saturation affect R2*-MRI for transfusional iron overload assessment? A clinical evaluation at 1.5T and 3T.

Authors:  Axel J Krafft; Ralf B Loeffler; Ruitian Song; Xiao Bian; M Beth McCarville; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

View more