Validation of cardiac output measurement with the LiDCO™ pulse contour system in patients with impaired left ventricular function after cardiac surgery.

B Mora1, I Ince, B Birkenberg, K Skhirtladze, E Pernicka, H J Ankersmit, M Dworschak.   

Abstract

After cardiac surgery, patients with low left ventricular ejection fraction probably benefit the most from accurate monitoring of continuous cardiac output. Thirty patients with impaired ventricular function were studied, and intermittent bolus thermodilution and continuous pulse contour (LiDCO plus™) cardiac output compared. Following lithium dilution calibration, a total of 220 paired results were recorded. Thermodilution and LiDCO measurements ranged from 2.3 to 11.0 and 2.6 to 10.8 l.min(-1), respectively. Corresponding means (SD) were 6.1 (1.6) and 6.2 (1.9) l.min(-1), with coefficients of variance of 26 and 31%, respectively. The correlation coefficient was 0.82, bias 0.28 l.min(-1) with upper and lower limits of agreement 1.96 and -1.41 l.min(-1); the percentage error was 27%. LiDCO showed good correlation, marginal bias and acceptable limits of agreement and percentage error. It could therefore potentially replace thermodilution as a means of measuring cardiac output in the ICU, particularly when determination of pulmonary artery pressure is not required.
© 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2011        PMID: 21564044     DOI: 10.1111/j.1365-2044.2011.06754.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  9 in total

1.  Validation of electrical velocimetry in resuscitation of patients undergoing liver transplantation. Observational study.

Authors:  Ahmed M Mukhtar; Mohamed Elayashy; Amr H Sayed; Gihan M Obaya; Akram A Eladawy; Mai A Ali; Hisham M Dahab; Dina Z Khalaf; Mostafa A Mohamed; Amr H Elfouly; Gad M Behairy; Amr A Abdelaal
Journal:  J Clin Monit Comput       Date:  2019-04-19       Impact factor: 2.502

2.  Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum.

Authors:  Marko Zlicar; Vesna Novak-Jankovic; Rok Blagus; Maurizio Cecconi
Journal:  J Clin Monit Comput       Date:  2017-11-17       Impact factor: 2.502

3.  Impact of hemodynamic goal-directed resuscitation on mortality in adult critically ill patients: a systematic review and meta-analysis.

Authors:  Maria Cronhjort; Olof Wall; Erik Nyberg; Ruifeng Zeng; Christer Svensen; Johan Mårtensson; Eva Joelsson-Alm
Journal:  J Clin Monit Comput       Date:  2017-06-08       Impact factor: 2.502

4.  Using bispectral index and cerebral oximetry to guide hemodynamic therapy in high-risk surgical patients.

Authors:  Heena Bidd; Audrey Tan; David Green
Journal:  Perioper Med (Lond)       Date:  2013-05-19

5.  The maintenance and monitoring of perioperative blood volume.

Authors:  Takehiko Iijima; Birgitte Brandstrup; Peter Rodhe; Audrius Andrijauskas; Christer H Svensen
Journal:  Perioper Med (Lond)       Date:  2013-05-07

6.  Less invasive methods of advanced hemodynamic monitoring: principles, devices, and their role in the perioperative hemodynamic optimization.

Authors:  Christos Chamos; Liana Vele; Mark Hamilton; Maurizio Cecconi
Journal:  Perioper Med (Lond)       Date:  2013-09-17

7.  Unreliable Tracking Ability of the Third-Generation FloTrac/Vigileo™ System for Changes in Stroke Volume after Fluid Administration in Patients with High Systemic Vascular Resistance during Laparoscopic Surgery.

Authors:  Ji-Hyun Chin; Wook-Jong Kim; Jeong-Hyun Choi; Yun A Han; Seon-Ok Kim; Woo-Jong Choi
Journal:  PLoS One       Date:  2015-11-03       Impact factor: 3.240

8.  Postoperative management of patients undergoing cardiac surgery in Austria : A national survey on current clinical practice in hemodynamic monitoring and postoperative management.

Authors:  Johannes Menger; Maximilian Edlinger-Stanger; Martin Dworschak; Barbara Steinlechner
Journal:  Wien Klin Wochenschr       Date:  2018-10-29       Impact factor: 1.704

Review 9.  Cardiac output monitoring: Technology and choice.

Authors:  Jeff Kobe; Nitasha Mishra; Virendra K Arya; Waiel Al-Moustadi; Wayne Nates; Bhupesh Kumar
Journal:  Ann Card Anaesth       Date:  2019 Jan-Mar