Literature DB >> 21559947

Validity of the Oxycon Mobile metabolic system under field measuring conditions.

Jane Salier Eriksson1, Hans Rosdahl, Peter Schantz.   

Abstract

This study aimed to validate a portable metabolic system in field measuring conditions, such as prolonged moderate exercise at low temperatures, high humidity and with external wind. VO(2), VCO(2), RER and V (E) were measured using the Oxycon Mobile (OM), with a windshield, during cycle ergometer exercise: (1) indoors at three submaximal workloads with no wind or with external wind (13-20 m s(-1)) from front, side and back; (2) at two submaximal workloads outdoors (12 ± 2°C; 86 ± 7% relative humidity (RH)), with and without a system for drying the ambient air around the air sampling tube; and (3) at one workload outdoors for 45 min (5 ± 4°C; 69 ± 16.5% RH). Any physiological drift was checked for with pre- and postmeasurements by the Douglas bag method (DBM). A minor effect of external wind from behind was noted in RER and V (E) (-2 and -3%). The system for drying the ambient air around the gas sampling tube had no effect on the measured levels. A small difference in VCO(2) drift between the OM and DBM (1.5 mL min(-2)) was noted in the stability test. The results indicated that heavy external wind applied from different directions generally does not affect the measurements of the OM and further that, when using a unit for drying the ambient air around the gas sampling tube, the OM can accurately measure VO(2), RER and V (E) at submaximal workloads for at least 45 min under challenging conditions with regard to humidity and temperature.

Entities:  

Mesh:

Year:  2011        PMID: 21559947     DOI: 10.1007/s00421-011-1985-1

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  9 in total

1.  CIRCULATORY RESPONSE TO PROLONGED SEVERE EXERCISE.

Authors:  B SALTIN; J STENBERG
Journal:  J Appl Physiol       Date:  1964-09       Impact factor: 3.531

Review 2.  Ambulatory gas exchange measurements--current status and future options.

Authors:  T Meyer; R C R Davison; W Kindermann
Journal:  Int J Sports Med       Date:  2005-02       Impact factor: 3.118

Review 3.  Performance characteristics of gas analysis systems: what we know and what we need to know.

Authors:  G Atkinson; R C R Davison; A M Nevill
Journal:  Int J Sports Med       Date:  2005-02       Impact factor: 3.118

Review 4.  Validity and reliability of selected commercially available metabolic analyzer systems.

Authors:  L D Hodges; D A Brodie; P D Bromley
Journal:  Scand J Med Sci Sports       Date:  2005-10       Impact factor: 4.221

5.  Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise.

Authors:  C Perret; G Mueller
Journal:  Int J Sports Med       Date:  2006-05       Impact factor: 3.118

Review 6.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

7.  Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method.

Authors:  Hans Rosdahl; Lennart Gullstrand; Jane Salier-Eriksson; Patrik Johansson; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2009-12-31       Impact factor: 3.078

8.  A respiratory gas exchange simulator for routine calibration in metabolic studies.

Authors:  A Huszczuk; B J Whipp; K Wasserman
Journal:  Eur Respir J       Date:  1990-04       Impact factor: 16.671

9.  Feasibility of mobile cardiopulmonary exercise testing.

Authors:  Adrian Attinger; Claudia Tüller; Tjeu Souren; Michael Tamm; Christian Schindler; Martin H Brutsche
Journal:  Swiss Med Wkly       Date:  2006-01-07       Impact factor: 2.193

  9 in total
  13 in total

1.  Age-Related Differences in OMNI-RPE Scale Validity in Youth: A Longitudinal Analysis.

Authors:  Catherine Gammon; Karin A Pfeiffer; James M Pivarnik; Rebecca W Moore; Kelly R Rice; Stewart G Trost
Journal:  Med Sci Sports Exerc       Date:  2016-08       Impact factor: 5.411

2.  Metabolic equivalent determination in the cultural dance of hula.

Authors:  T Usagawa; M Look; M de Silva; C Stickley; J K Kaholokula; T Seto; M Mau
Journal:  Int J Sports Med       Date:  2013-11-07       Impact factor: 3.118

Review 3.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

4.  The validity of the Moxus Modular metabolic system during incremental exercise tests: impacts on detection of small changes in oxygen consumption.

Authors:  Fernando G Beltrami; Christian Froyd; Asgeir Mamen; Timothy D Noakes
Journal:  Eur J Appl Physiol       Date:  2014-01-30       Impact factor: 3.078

5.  Prediction of Cardiorespiratory Fitness by the Six-Minute Step Test and Its Association with Muscle Strength and Power in Sedentary Obese and Lean Young Women: A Cross-Sectional Study.

Authors:  Lívia Pinheiro Carvalho; Luciana Di Thommazo-Luporini; Mylène Aubertin-Leheudre; José Carlos Bonjorno Junior; Cláudio Ricardo de Oliveira; Rafael Luís Luporini; Renata Gonçalves Mendes; Katiany Thais Lopes Zangrando; Renata Trimer; Ross Arena; Audrey Borghi-Silva
Journal:  PLoS One       Date:  2015-12-30       Impact factor: 3.240

6.  Gas analyzer's drift leads to systematic error in maximal oxygen uptake and maximal respiratory exchange ratio determination.

Authors:  Ibai Garcia-Tabar; Jean P Eclache; José F Aramendi; Esteban M Gorostiaga
Journal:  Front Physiol       Date:  2015-10-30       Impact factor: 4.566

7.  Perspectives on Exercise Intensity, Volume and Energy Expenditure in Habitual Cycle Commuting.

Authors:  Peter Schantz; Jane Salier Eriksson; Hans Rosdahl
Journal:  Front Sports Act Living       Date:  2020-06-30

8.  Walking performance: correlation between energy cost of walking and walking participation. new statistical approach concerning outcome measurement.

Authors:  Marco Franceschini; Anais Rampello; Maurizio Agosti; Maurizio Massucci; Federica Bovolenta; Patrizio Sale
Journal:  PLoS One       Date:  2013-02-28       Impact factor: 3.240

9.  The heart rate method for estimating oxygen uptake: analyses of reproducibility using a range of heart rates from commuter walking.

Authors:  Peter Schantz; Jane Salier Eriksson; Hans Rosdahl
Journal:  Eur J Appl Physiol       Date:  2019-10-18       Impact factor: 3.078

10.  Heart Rate Methods Can Be Valid for Estimating Intensity Spectrums of Oxygen Uptake in Field Exercise.

Authors:  Jane Salier Eriksson; Karin S E Olsson; Hans Rosdahl; Peter Schantz
Journal:  Front Physiol       Date:  2021-07-06       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.