A respiratory gas exchange simulator for routine calibration in metabolic studies.

A Huszczuk1, B J Whipp, K Wasserman.   

Abstract

We have developed a method for simulating respiratory gas exchange for on-line calibration of metabolic measurement systems. It utilizes a pump which intakes a mixture of atmospheric air and a known flow of precision-analysed calibration gas (21% CO2, 79% N2). It expels the resulting mixture with flow wave form and profiles of gas concentration which closely resemble those of normal expiration. Control of the calibration mixture's inflow allows the investigator to set any desired metabolic rate regardless of the minute ventilatory rate. This separation of metabolic from ventilatory rates provides a stringent test of the computational performance of the respiratory gas exchange measurement systems. The apparatus can reproduce any range of respiratory and metabolic performance (currently ranging from 0.2-5 l.min-1 O2 uptake and CO2 output) with accuracy +/- 2%.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2114308

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  20 in total

1.  Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system.

Authors:  D J Macfarlane; P Wong
Journal:  Eur J Appl Physiol       Date:  2011-11-11       Impact factor: 3.078

2.  The effects of 24 weeks of moderate- or high-intensity exercise on insulin resistance.

Authors:  Gary O'Donovan; Edward M Kearney; Alan M Nevill; Kate Woolf-May; Steve R Bird
Journal:  Eur J Appl Physiol       Date:  2005-09-06       Impact factor: 3.078

Review 3.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

4.  Noninvasive assessment of normality of VD/VT in clinical cardiopulmonary exercise testing utilizing incremental cycle ergometry.

Authors:  Michael A Roman; James D Casaburi; Janos Porszasz; Richard Casaburi
Journal:  Eur J Appl Physiol       Date:  2012-05-06       Impact factor: 3.078

5.  Muscle substrate utilization from alveolar gas exchange in trained cyclists.

Authors:  M Riley; K Wasserman; P C Fu; C B Cooper
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

6.  Validity of the Oxycon Mobile metabolic system under field measuring conditions.

Authors:  Jane Salier Eriksson; Hans Rosdahl; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2011-05-11       Impact factor: 3.078

7.  The Moxus Modular metabolic system evaluated with two sensors for ventilation against the Douglas bag method.

Authors:  Hans Rosdahl; Thomas Lindberg; Fredrik Edin; Johnny Nilsson
Journal:  Eur J Appl Physiol       Date:  2012-12-07       Impact factor: 3.078

8.  Non-invasive prediction of blood lactate response to constant power outputs from incremental exercise tests.

Authors:  C S Sullivan; R Casaburi; T W Storer; K Wasserman
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

Review 9.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

10.  Simulation system for a rebreathing technique to measure multiple cardiopulmonary function parameters.

Authors:  Cuneyt Yilmaz; William W Chance; Robert L Johnson; Connie C W Hsia
Journal:  Chest       Date:  2009-05       Impact factor: 9.410