Literature DB >> 21539529

Non-invasive prediction of fluid responsiveness in infants using pleth variability index.

J Renner1, O Broch, M Gruenewald, J Scheewe, H Francksen, O Jung, M Steinfath, B Bein.   

Abstract

This prospective study assessed whether respiratory variations in velocity time integral, peak blood flow velocity and non-invasive pleth variability index are useful measurements in infants undergoing congenital heart surgery and determined threshold values that may help guide fluid administration. In 27 infants receiving mechanical ventilation, of mean (SD) weight 10.4 (6.3) kg, 13 increased their stroke volume index ≥ 15% following a fluid challenge and 14 did not. The best area under the receiver operating characteristic curve was for the echocardiographic-derived variables respiratory variation in blood peak flow velocity (area under the ROC curve = 0.92; p = 0.0002) and respiratory variation of the velocity time integral (area under the ROC curve = 0.84; p = 0.002). The pleth variability index also predicted fluid responsiveness (area under the ROC curve = 0.79; p = 0.01), in contrast to heart rate (area under the ROC curve = 0.53; p = 0.75) and central venous pressure (area under the ROC curve = 0.57; p = 0.52).
© 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2011        PMID: 21539529     DOI: 10.1111/j.1365-2044.2011.06715.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  20 in total

1.  Pulse oximeter plethysmograph variation and its relationship to the arterial waveform in mechanically ventilated children.

Authors:  J R Chandler; E Cooke; C Petersen; W Karlen; N Froese; J Lim; J M Ansermino
Journal:  J Clin Monit Comput       Date:  2012-03-10       Impact factor: 2.502

2.  Using non invasive dynamic parameters of fluid responsiveness in children: there is still much to learn.

Authors:  Elena Chung; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2012-03-20       Impact factor: 2.502

Review 3.  Accuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.

Authors:  Haitao Chu; Yong Wang; Yanfei Sun; Gang Wang
Journal:  J Clin Monit Comput       Date:  2015-08-05       Impact factor: 2.502

4.  Prediction of volume responsiveness using pleth variability index in patients undergoing cardiac surgery after cardiopulmonary bypass.

Authors:  Sebastian Haas; Constantin Trepte; Martin Hinteregger; Rebecca Fahje; Bjoern Sill; Lena Herich; Daniel A Reuter
Journal:  J Anesth       Date:  2012-05-16       Impact factor: 2.078

5.  Accuracy of pulse oximeter perfusion index in thoracic epidural anesthesia under basal general anesthesia.

Authors:  Zifeng Xu; Jianhai Zhang; Yunfei Xia; Xiaoming Deng
Journal:  Int J Clin Exp Med       Date:  2014-07-15

Review 6.  [Hemodynamic monitoring in pediatric anesthesia].

Authors:  Andreas Otte; Ehrenfried Schindler; Claudia Neumann
Journal:  Anaesthesiologie       Date:  2022-05-23

7.  Pediatric robotic surgery: issues in management-expert consensus from the Italian Society of Pediatric and Neonatal Anesthesia and Intensive Care (SARNePI) and the Italian Society of Pediatric Surgery (SICP).

Authors:  Simonetta Tesoro; Piergiorgio Gamba; Mirko Bertozzi; Rachele Borgogni; Fabio Caramelli; Giovanni Cobellis; Giuseppe Cortese; Ciro Esposito; Tommaso Gargano; Rossella Garra; Giulia Mantovani; Laura Marchesini; Simonetta Mencherini; Mario Messina; Gerald Rogan Neba; Gloria Pelizzo; Simone Pizzi; Giovanna Riccipetitoni; Alessandro Simonini; Costanza Tognon; Mario Lima
Journal:  Surg Endosc       Date:  2022-09-19       Impact factor: 3.453

8.  The ability of stroke volume variation measured by a noninvasive cardiac output monitor to predict fluid responsiveness in mechanically ventilated children.

Authors:  Ji Yeon Lee; Ji Young Kim; Chang Hyu Choi; Hong Soon Kim; Kyung Cheon Lee; Hyun Jeong Kwak
Journal:  Pediatr Cardiol       Date:  2013-08-21       Impact factor: 1.655

9.  Evaluation of fluid responsiveness: is photoplethysmography a noninvasive alternative?

Authors:  Lars Prag Antonsen; Knut Arvid Kirkebøen
Journal:  Anesthesiol Res Pract       Date:  2012-02-28

10.  The influence of different mechanical ventilator settings of peak inspiratory pressure on stroke volume variation in pediatric cardiac surgery patients.

Authors:  Woon-Seok Kang; Jae Yun Kim; Nam Sik Woo; Tae Gyoon Yoon
Journal:  Korean J Anesthesiol       Date:  2014-05-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.