Literature DB >> 17716317

Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study.

N Van Assche1, D van Steenberghe, M E Guerrero, E Hirsch, F Schutyser, M Quirynen, R Jacobs.   

Abstract

AIM: To evaluate the precision of transfer of a computer-based three-dimensional (3D) planning, using re-formatted cone-beam images, for oral implant placement in partially edentulous jaws.
MATERIAL AND METHODS: Four formalin-fixed cadaver jaws were imaged in a 3D Accuitomo FPD cone-beam computed tomography (CT). Data were used to produce an accurate implant planning with a transfer to surgery by means of stereolithographic drill guides. Pre-operative cone-beam CT images were subsequently matched with post-operative ones to calculate the deviation between planned and installed implants.
RESULTS: Placed implants (length: 10-15 mm) showed an average angular deviation of 2 degrees (SD: 0.8, range: 0.7-4.0 degrees ) as compared with the planning, while the mean linear deviation was 1.1 mm (SD: 0.7 mm, range 0.3-2.3 mm) at the hex and 2.0 mm (SD: 0.7 mm, range 0.7-2.4 mm) at the tip.
CONCLUSIONS: Cone-beam images could be used for implant planning, taking into account a maximal 4 degrees angular and 2.4 mm linear deviation at the apical tip.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17716317     DOI: 10.1111/j.1600-051X.2007.01110.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  41 in total

1.  The influence of exposure parameters on jawbone model accuracy using cone beam CT and multislice CT.

Authors:  B Vandenberghe; S Luchsinger; J Hostens; E Dhoore; R Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

Review 2.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

3.  Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement.

Authors:  Wei Geng; Changying Liu; Yucheng Su; Jun Li; Yanmin Zhou
Journal:  Int J Clin Exp Med       Date:  2015-06-15

4.  Cone-beam computed tomography in assessment of periodontal ligament space: in vitro study on artificial tooth model.

Authors:  Nurdan Ozmeric; Irina Kostioutchenko; Georg Hägler; Matthias Frentzen; Pia-Merete Jervøe-Storm
Journal:  Clin Oral Investig       Date:  2008-02-05       Impact factor: 3.573

5.  A novel workflow for computer guided implant surgery matching digital dental casts and CBCT scan.

Authors:  G DE Vico; F Ferraris; L Arcuri; F Guzzo; D Spinelli
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

6.  A fully 3D work context for oral implant planning and simulation.

Authors:  Tommaso Chiarelli; Evelina Lamma; Tommaso Sansoni
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-07-24       Impact factor: 2.924

7.  Calibrated segmentation of CBCT and CT images for digitization of dental prostheses.

Authors:  Veerle Wouters; Wouter Mollemans; Filip Schutyser
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-05-03       Impact factor: 2.924

8.  Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations.

Authors:  C Tomasi; E Bressan; B Corazza; S Mazzoleni; E Stellini; A Lith
Journal:  Dentomaxillofac Radiol       Date:  2011-05       Impact factor: 2.419

9.  Variability of dental cone beam CT grey values for density estimations.

Authors:  R Pauwels; O Nackaerts; N Bellaiche; H Stamatakis; K Tsiklakis; A Walker; H Bosmans; R Bogaerts; R Jacobs; K Horner
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

10.  Assessment of bone channels other than the nasopalatine canal in the anterior maxilla using limited cone beam computed tomography.

Authors:  Thomas von Arx; Scott Lozanoff; Pedram Sendi; Michael M Bornstein
Journal:  Surg Radiol Anat       Date:  2013-03-29       Impact factor: 1.246