Literature DB >> 21536523

Compressed sensing with wavelet domain dependencies for coronary MRI: a retrospective study.

Mehmet Akçakaya1, Seunghoon Nam, Peng Hu, Mehdi H Moghari, Long H Ngo, Vahid Tarokh, Warren J Manning, Reza Nezafat.   

Abstract

Coronary magnetic resonance imaging (MRI) is a noninvasive imaging modality for diagnosis of coronary artery disease. One of the limitations of coronary MRI is its long acquisition time due to the need of imaging with high spatial resolution and constraints on respiratory and cardiac motions. Compressed sensing (CS) has been recently utilized to accelerate image acquisition in MRI. In this paper, we develop an improved CS reconstruction method, Bayesian least squares-Gaussian scale mixture (BLS-GSM), that uses dependencies of wavelet domain coefficients to reduce the observed blurring and reconstruction artifacts in coronary MRI using traditional l(1) regularization. Images of left and right coronary MRI was acquired in 7 healthy subjects with fully-sampled k-space data. The data was retrospectively undersampled using acceleration rates of 2, 4, 6, and 8 and reconstructed using l(1) thresholding, l(1) minimization and BLS-GSM thresholding. Reconstructed right and left coronary images were compared with fully-sampled reconstructions in vessel sharpness and subjective image quality (1-4 for poor-excellent). Mean square error (MSE) was also calculated for each reconstruction. There were no significant differences between the fully sampled image score versus rate 2, 4, or 6 for BLS-GSM for both right and left coronaries (=N.S.). However, for l(1) thresholding significant differences were observed for rates higher than 2 and 4 for right and left coronaries respectively. l(1) minimization also yields images with lower scores compared to the reference for rates higher than 4 for both coronaries. These results were consistent with the quantitative vessel sharpness readings. BLS-GSM allows acceleration of coronary MRI with acceleration rates beyond what can be achieved with l(1) regularization.

Entities:  

Mesh:

Year:  2011        PMID: 21536523      PMCID: PMC4212510          DOI: 10.1109/TMI.2010.2089519

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  24 in total

1.  Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography.

Authors:  M Stuber; R M Botnar; P G Danias; D K Sodickson; K V Kissinger; M Van Cauteren; J De Becker; W J Manning
Journal:  J Am Coll Cardiol       Date:  1999-08       Impact factor: 24.094

2.  Image denoising using scale mixtures of Gaussians in the wavelet domain.

Authors:  Javier Portilla; Vasily Strela; Martin J Wainwright; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

3.  An EM algorithm for wavelet-based image restoration.

Authors:  Mário A T Figueiredo; Robert D Nowak
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

4.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging.

Authors:  Himanshu Bhat; Qi Yang; Sven Zuehlsdorff; Kuncheng Li; Debiao Li
Journal:  Invest Radiol       Date:  2010-08       Impact factor: 6.016

5.  Coronary magnetic resonance angiography for the detection of coronary stenoses.

Authors:  W Y Kim; P G Danias; M Stuber; S D Flamm; S Plein; E Nagel; S E Langerak; O M Weber; E M Pedersen; M Schmidt; R M Botnar; W J Manning
Journal:  N Engl J Med       Date:  2001-12-27       Impact factor: 91.245

6.  Coronary angiography with magnetization-prepared T2 contrast.

Authors:  J H Brittain; B S Hu; G A Wright; C H Meyer; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

7.  Executive summary: heart disease and stroke statistics--2010 update: a report from the American Heart Association.

Authors:  Donald Lloyd-Jones; Robert J Adams; Todd M Brown; Mercedes Carnethon; Shifan Dai; Giovanni De Simone; T Bruce Ferguson; Earl Ford; Karen Furie; Cathleen Gillespie; Alan Go; Kurt Greenlund; Nancy Haase; Susan Hailpern; P Michael Ho; Virginia Howard; Brett Kissela; Steven Kittner; Daniel Lackland; Lynda Lisabeth; Ariane Marelli; Mary M McDermott; James Meigs; Dariush Mozaffarian; Michael Mussolino; Graham Nichol; Véronique L Roger; Wayne Rosamond; Ralph Sacco; Paul Sorlie; Randall Stafford; Thomas Thom; Sylvia Wasserthiel-Smoller; Nathan D Wong; Judith Wylie-Rosett
Journal:  Circulation       Date:  2010-02-23       Impact factor: 29.690

8.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

9.  Improving non-contrast-enhanced steady-state free precession angiography with compressed sensing.

Authors:  Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

10.  Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent.

Authors:  Xiaoming Bi; James C Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2007-07       Impact factor: 3.737

View more
  16 in total

1.  Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging.

Authors:  Holden H Wu; Paul T Gurney; Bob S Hu; Dwight G Nishimura; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

2.  Four-dimensional respiratory motion-resolved whole heart coronary MR angiography.

Authors:  Davide Piccini; Li Feng; Gabriele Bonanno; Simone Coppo; Jérôme Yerly; Ruth P Lim; Juerg Schwitter; Daniel K Sodickson; Ricardo Otazo; Matthias Stuber
Journal:  Magn Reson Med       Date:  2016-03-28       Impact factor: 4.668

3.  Self-supervised learning of physics-guided reconstruction neural networks without fully sampled reference data.

Authors:  Burhaneddin Yaman; Seyed Amir Hossein Hosseini; Steen Moeller; Jutta Ellermann; Kâmil Uğurbil; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2020-07-02       Impact factor: 4.668

4.  Accelerated contrast-enhanced whole-heart coronary MRI using low-dimensional-structure self-learning and thresholding.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Hussein Rayatzadeh; Kraig V Kissinger; Beth Goddu; Lois A Goepfert; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

5.  Dense Recurrent Neural Networks for Accelerated MRI: History-Cognizant Unrolling of Optimization Algorithms.

Authors:  Seyed Amir Hossein Hosseini; Burhaneddin Yaman; Steen Moeller; Mingyi Hong; Mehmet Akçakaya
Journal:  IEEE J Sel Top Signal Process       Date:  2020-06-17       Impact factor: 6.856

6.  Iterative Shrinkage Algorithm for Patch-Smoothness Regularized Medical Image Recovery.

Authors:  Yasir Q Mohsin; Gregory Ongie; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2015-01-30       Impact factor: 10.048

7.  Accelerated isotropic sub-millimeter whole-heart coronary MRI: compressed sensing versus parallel imaging.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

8.  Low-Rank Tensor Models for Improved Multi-Dimensional MRI: Application to Dynamic Cardiac T 1 Mapping.

Authors:  Burhaneddin Yaman; Sebastian Weingärtner; Nikolaos Kargas; Nicholas D Sidiropoulos; Mehmet Akçakaya
Journal:  IEEE Trans Comput Imaging       Date:  2019-09-12

9.  Real-Time Compressive Sensing MRI Reconstruction Using GPU Computing and Split Bregman Methods.

Authors:  David S Smith; John C Gore; Thomas E Yankeelov; E Brian Welch
Journal:  Int J Biomed Imaging       Date:  2012-02-01

Review 10.  Advanced respiratory motion compensation for coronary MR angiography.

Authors:  Markus Henningsson; Rene M Botnar
Journal:  Sensors (Basel)       Date:  2013-05-24       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.