Literature DB >> 21511923

Cross-linked versus conventional polyethylene for total hip replacement: a meta-analysis of randomised controlled trials.

P R T Kuzyk1, M Saccone, S Sprague, N Simunovic, M Bhandari, E H Schemitsch.   

Abstract

We conducted a systematic review and meta-analysis of randomised controlled trials comparing cross-linked with conventional polyethylene liners for total hip replacement in order to determine whether these liners reduce rates of wear, radiological evidence of osteolysis and the need for revision. The MEDLINE, EMBASE and COCHRANE databases were searched from their inception to May 2010 for all trials involving the use of cross-linked polyethylene in total hip replacement. Eligibility for inclusion in the review included the random allocation of treatments, the use of cross-linked and conventional polyethylene, and radiological wear as an outcome measure. The pooled mean differences were calculated for bedding-in, linear wear rate, three-dimensional linear wear rate, volumetric wear rate and total linear wear. Pooled risk ratios were calculated for radiological osteolysis and revision hip replacement. A search of the literature identified 194 potential studies, of which 12 met the inclusion criteria. All reported a significant reduction in radiological wear for cross-linked polyethylene. The pooled mean differences for linear rate of wear, three-dimensional linear rate of wear, volumetric wear rate and total linear wear were all significantly reduced for cross-linked polyethylene. The risk ratio for radiological osteolysis was 0.40 (95% confidence interval 0.27 to 0.58; I(2) = 0%), favouring cross-linked polyethylene. The follow-up was not long enough to show a difference in the need for revision surgery.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21511923     DOI: 10.1302/0301-620X.93B5.25908

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  30 in total

1.  CORR Insights(®): oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  Alexander Jaime Grübl
Journal:  Clin Orthop Relat Res       Date:  2015-09-10       Impact factor: 4.176

2.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

Review 3.  Mediators of the inflammatory response to joint replacement devices.

Authors:  Neil Cobelli; Brian Scharf; Giovanna M Crisi; John Hardin; Laura Santambrogio
Journal:  Nat Rev Rheumatol       Date:  2011-09-06       Impact factor: 20.543

4.  Do oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial.

Authors:  Amine Zaoui; Samer El Hage; Jean Langlois; Caroline Scemama; Jean Pierre Courpied; Moussa Hamadouche
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

Review 5.  [Tribology in hip arthroplasty : Benefits of different materials].

Authors:  J Philippe Kretzer; Maximilian Uhler; Sebastian Jäger; Therese Bormann; Robert Sonntag; Mareike Schonhoff; Stefan Schröder
Journal:  Orthopade       Date:  2021-02-25       Impact factor: 1.087

6.  Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.

Authors:  Caroline Scemama; Philippe Anract; Valérie Dumaine; Antoine Babinet; Jean Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2016-11-04       Impact factor: 3.075

7.  Is there a difference in total knee arthroplasty risk of revision in highly crosslinked versus conventional polyethylene?

Authors:  Elizabeth W Paxton; Maria C S Inacio; Steven Kurtz; Rebecca Love; Guy Cafri; Robert S Namba
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

8.  Metal-on-conventional polyethylene total hip arthroplasty bearing surfaces have a higher risk of revision than metal-on-highly crosslinked polyethylene: results from a US registry.

Authors:  Elizabeth W Paxton; Maria C S Inacio; Robert S Namba; Rebecca Love; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

9.  CORR Insights ®: Metal-on-conventional total hip arthroplasty bearing surfaces have a higher risk of revision than metal-on-highly crosslinked polyethylene: results from a US registry.

Authors:  Richard W McCalden
Journal:  Clin Orthop Relat Res       Date:  2015-01-31       Impact factor: 4.176

10.  Surgical Approaches to OA Therapy: Osteotomy and Arthroplasty.

Authors:  John J Callaghan
Journal:  HSS J       Date:  2011-12-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.