Literature DB >> 21509813

High spatial and temporal resolution imaging of the arterial vasculature of the lower extremity with contrast enhanced MR angiography.

Petrice M Mostardi1, Clifton R Haider, James F Glockner, Phillip M Young, Stephen J Riederer.   

Abstract

Vascular imaging can be essential in the diagnosis, monitoring, and planning and assessment of treatment of patients with peripheral vascular disease. The purpose of this work is to describe a recently developed three-dimensional (3D) time-resolved contrast-enhanced MR angiography (CE-MRA) technique, Cartesian Acquisition with Projection Reconstruction-like sampling (CAPR), and its application to imaging of the vasculature of the lower legs and feet. CAPR implements accelerated imaging techniques and uses specialized multielement imaging coil arrays to achieve high temporal and high spatial resolution imaging. Volunteer and patient studies of the vasculature of the lower legs and feet have been performed. Temporal resolution of 4.9-6.5 sec and spatial resolution less than or equal to 1 mm in all directions allow for the depiction of progressive arterial filling and complex flow patterns as well as sharp visualization of vascular structure as small as the fine muscular branches. High-quality diagnostic imaging is made possible with CAPR's advanced acquisition and reconstruction techniques and the use of specialized coil arrays.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21509813      PMCID: PMC3135762          DOI: 10.1002/ca.21124

Source DB:  PubMed          Journal:  Clin Anat        ISSN: 0897-3806            Impact factor:   2.414


  28 in total

1.  Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy.

Authors:  M A Bernstein; S B Fain; S J Riederer
Journal:  J Magn Reson Imaging       Date:  2001-09       Impact factor: 4.813

2.  MDCT compared with digital subtraction angiography for assessment of lower extremity arterial occlusive disease: importance of reviewing cross-sectional images.

Authors:  Hideki Ota; Kei Takase; Kazumasa Igarashi; Yoshihiro Chiba; Kenichi Haga; Haruo Saito; Shoki Takahashi
Journal:  AJR Am J Roentgenol       Date:  2004-01       Impact factor: 3.959

3.  High-resolution, time-resolved MRA provides superior definition of lower-extremity arterial segments compared to 2D time-of-flight imaging.

Authors:  F J Thornton; J Du; S A Suleiman; R Dieter; G Tefera; K R Pillai; F R Korosec; C A Mistretta; T M Grist
Journal:  J Magn Reson Imaging       Date:  2006-08       Impact factor: 4.813

4.  Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II).

Authors:  L Norgren; W R Hiatt; J A Dormandy; M R Nehler; K A Harris; F G R Fowkes
Journal:  J Vasc Surg       Date:  2007-01       Impact factor: 4.268

5.  Peripheral arteries in diabetic patients: standard bolus-chase and time-resolved MR angiography.

Authors:  Gustav Andreisek; Thomas Pfammatter; Kerstin Goepfert; Daniel Nanz; Patrice Hervo; Renate Koppensteiner; Dominik Weishaupt
Journal:  Radiology       Date:  2006-12-19       Impact factor: 11.105

6.  Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

Review 7.  Diagnostic performance of computed tomography angiography in peripheral arterial disease: a systematic review and meta-analysis.

Authors:  Rosemarie Met; Shandra Bipat; Dink A Legemate; Jim A Reekers; Mark J W Koelemay
Journal:  JAMA       Date:  2009-01-28       Impact factor: 56.272

8.  Peripheral vasculature: high-temporal- and high-spatial-resolution three-dimensional contrast-enhanced MR angiography.

Authors:  Clifton R Haider; James F Glockner; Anthony W Stanson; Stephen J Riederer
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

Review 9.  Indications and clinical outcomes for below knee endovascular therapy: review article.

Authors:  Lanfroi Graziani; Alberto Piaggesi
Journal:  Catheter Cardiovasc Interv       Date:  2010-02-15       Impact factor: 2.692

10.  Dynamic gadolinium-enhanced three-dimensional abdominal MR arteriography.

Authors:  M R Prince; E K Yucel; J A Kaufman; D C Harrison; S C Geller
Journal:  J Magn Reson Imaging       Date:  1993 Nov-Dec       Impact factor: 4.813

View more
  1 in total

1.  High temporal and spatial resolution imaging of peripheral vascular malformations.

Authors:  Petrice M Mostardi; Phillip M Young; Michael A McKusick; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2012-06-04       Impact factor: 4.813

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.