Literature DB >> 21504478

Removable four implant-supported mandibular overdentures rigidly retained with telescopic crowns or milled bars: a 3-year prospective study.

Gerald Krennmair1, Daniel Sütö, Rudolf Seemann, Eva Piehslinger.   

Abstract

PURPOSE: The present study evaluated implant survival/success rate, peri-implant parameters and prosthodontic maintenance efforts for four implant-supported mandibular overdentures (IOD) rigidly retained on either milled bar or double crowns (telescopic) attachments.
MATERIAL AND METHODS: In a randomized prospective trial, 51 patients with edentulism received four mandibular interforaminal implants and complete maxillary dentures. For IOD, rigid denture stabilization was chosen randomly selecting 26 patients for milled bars (group I) and 25 patients for double (telescopic) crowns (group II). During a 3-year follow-up period, implant survival/success, peri-implant parameters (marginal bone resorption, pocket depth, plaque-, bleeding-, gingival index [BI and GI], calculus) and prosthodontic maintenance efforts were evaluated and compared between both retention modalities used.
RESULTS: Forty-five patients (23 group I, 22 group II) were available for a 3-year follow-up (dropout rate: 11.8%) presenting a high implant survival/success rate (100%). Peri-implant marginal bone resorption, pocket depth as well as BI and GI did not differ for both rigid retention modalities. However, annually higher values for plaque- (NS) and calculus index (P<0.035) were noticed for the bar (group I) than for the telescopic crown (group II) attachments. Prevalence of prosthodontic maintenance did not differ between both retention modalities (group I: 0.41/maintenance efforts/year/patients vs. group II; 0.45 maintenance/efforts/year/patients). However, prosthodontic adaption for handling mechanism showed benefits for the bar retention.
CONCLUSION: Rigid anchoring of IOD retained either by bar or telescopic attachments showed high implant success rates and minor prosthodontic maintenance efforts regardless of retention modalities used. Stable denture retention presented healthy peri-implant structure for implants in bar and telescopic anchoring systems. Drawbacks such as higher plaque/calculus for bar retention and less favorable handling properties (output) for telescopic crown attachment leave the decision on the selection at the discretion of the clinician.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2011        PMID: 21504478     DOI: 10.1111/j.1600-0501.2011.02169.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  9 in total

1.  The use of dental implants, cast bars and sleeve overdentures in oral cancer patients.

Authors:  R Ali; A Al-Khayatt; C Barclay
Journal:  Br Dent J       Date:  2018-04-20       Impact factor: 1.626

2.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

Review 3.  A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: post-loading implant loss.

Authors:  Jaana-Sophia Kern; Thomas Kern; Stefan Wolfart; Nicole Heussen
Journal:  Clin Oral Implants Res       Date:  2015-02-09       Impact factor: 5.977

Review 4.  Prosthodontic maintenance and peri-implant tissue conditions for telescopic attachment-retained mandibular implant overdenture: Systematic review and meta-analysis of randomized clinical trials.

Authors:  Ahmed Mohamed Keshk; Ahmed Yaseen Alqutaibi; Radhwan S Algabri; Mostafa S Swedan; Amal Kaddah
Journal:  Eur J Dent       Date:  2017 Oct-Dec

5.  Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review.

Authors:  Jeong-Gyo Seo; Jin-Hyun Cho
Journal:  J Adv Prosthodont       Date:  2020-02-20       Impact factor: 1.904

Review 6.  Mandibular implant-supported overdenture: A systematic review and meta-analysis for optimum selection of attachment system.

Authors:  Priyanka Vaibhav Sutariya; Hitendra Mohanlal Shah; Surbhi Dipakbhai Patel; Hemil Hitesh Upadhyay; Mansoorkhan Rafikahmed Pathan; Rutu Paresh Shah
Journal:  J Indian Prosthodont Soc       Date:  2021 Oct-Dec

7.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11

8.  Implant-supported overdentures with different bar designs: A retrospective evaluation after 5-19 years of clinical function.

Authors:  Sven Rinke; Hajo Rasing; Nikolaus Gersdorff; Ralf Buergers; Matthias Roediger
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

9.  Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns.

Authors:  Sven Rinke; Ralf Buergers; Dirk Ziebolz; Matthias Roediger
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.