Implant-supported overdentures with different bar designs: A retrospective evaluation after 5-19 years of clinical function.

Sven Rinke1, Hajo Rasing2, Nikolaus Gersdorff2, Ralf Buergers2, Matthias Roediger2.   

Abstract

PURPOSE: This retrospective study evaluated the outcome of implant-retained overdentures (IODs) after 5-19 years of clinical function.
MATERIALS AND METHODS: A retrospective analysis of patient files was performed referring to 27 patients who received 36 IODs with 3 different bar designs (group A=prefabricated round bars, n=7; group B=one-piece anterior milled bars, n=20; and group C=two bilaterally placed milled bars, n=9) in the mandible (n=24) and/or in the maxilla (n=12). The analysis focused on the survival and success rates (according to Kaplan-Meier) of the implants and prostheses. Technical complication rates for each type of restoration were analyzed and compared via one-way ANOVA and the Chi-squared test. The prevalence of peri-implantitis (radiographic bone loss ≥3.5 mm) was evaluated by digital analysis of panoramic radiographs taken post-operative (baseline) and after 5-19 years of clinical function (follow-up).
RESULTS: The mean observational time was 7.3 years. The survival rates of the prostheses and implants were 100% and 97.7%, respectively. Technical complications occurred more frequently in group A (mean: 3.5 during observational time) than in the other two groups (B: 0.8; C: 1.0). However, this difference was not statistically significant (P=0.58). Peri-implantitis was diagnosed for 12.4% of the implants in 37% of the patients.
CONCLUSION: Bar-retained IODs are an adequate treatment option for edentulous jaws. These restorations may exhibit high implant/prosthesis survival rates (>97%), and a limited incidence of technical complications after a mean observational period of >7 years. Nevertheless, peri-implantitis was identified as a frequent and serious biological complication for this type of reconstruction.

Entities:  

Keywords:  Bar-retained overdentures; Implants; Marginal bone level; Peri-implantitis; Radiographic

Year:  2015        PMID: 26330982      PMCID: PMC4551791          DOI: 10.4047/jap.2015.7.4.338

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


INTRODUCTION

Bar-retained implant overdentures (IODs) are a common treatment option in implant prosthodontics, and the implants that support the prosthetic restorations exhibit high survival rates.123 It has been discussed controversially if the number of implants or a placing of extensions on bars influence the clinical outcome of IODs.45678 However, the data on the prevalence of biological complications remains limited.910 It has been proven that the bone resorption for IODs on prefabricated bars is lower in comparison with IODs on cast bars.11 In contrast, a systematic review demonstrated similar bone loss around implants supporting IODs with different attachment designs.12 This retrospective study examined the survival and success rates as well as the prevalence of peri-implantitis of IODs retained by 3 different bar designs.

MATERIALS AND METHODS

This study is based on patient files from the departments of Maxillofacial Surgery and Prosthodontics of the University Medical Center Goettingen. It was approved by the local ethics committee (approval no. 1/9/09). Twenty-seven patients (16 female, 11 male) were treated between 1991 and 2006 with IODs (n=36) that were retained by 3 different bar designs (group A=prefabricated round bars without extensions, resilient anchorage, n=7; group B=one-piece anterior milled bars with distal extensions, rigid anchorage, n=20; and group C=two bilaterally placed milled bars, with distal extensions, rigid anchorage, n=9) on 4 to 6 implants (2 - 3 per side) (n=161, mean: 4.5 per jaw) in the mandible (n=24) and/or in the maxilla (n=12). Inclusion criteria for the study were in compliance with annual recall intervals, a post-operative (baseline) panoramic radiograph, and at least one follow-up panoramic radiograph after a minimum observational period of 5 years (mean: 7.3 ± 3.6 years; range: 5-19 years). Furthermore, the complete documentation of all implant- and prosthesisrelated technical complications was mandatory for inclusion in the study. All radiographs were digitally analyzed (Adobe Photoshop CS4, San Jose, CA, USA). Calibration was performed by referencing the documented implant length. The marginal bone levels were calculated on the basis of the radiographic linear distance from the implant shoulder to the first bone-to-implant contact (Fig. 1). Radiographic bone loss during the functional period was calculated by subtracting the linear distance from the implant shoulder to the marginal bone level at baseline from the distance from the implant shoulder to the marginal bone level at the last available radiograph.
Fig. 1

Measurement of radiographic bone loss. (A) Baseline after implant insertion, (B) After 5 years of clinical function. The implant length is marked for calibration (green line), and the highest bone loss at implant 032 (mesial site, red line) is also marked.

Bone loss ≥3.5 mm was defined as "peri-implantitis".91013 Furthermore, all prosthodontic maintenance was recorded for the survival and success analysis according to Kaplan-Meier. Technical complication rates for each type of restoration were analyzed and compared via one-way ANOVA and the Chi-squared test (Software R version 2.8, www.r-project.org). A type one error of <0.05 was accepted as statistical significance.

RESULTS

Two implants (one in the maxilla after 7 years and one in the mandible after 6 years) had to be removed (7-year survival rate: 97.7%). All IODs remained in function (7-year survival rate: 100%). In total, 70 of the technical complications (attachment-related: 49%, denture-related: 51%) required clinical intervention to maintain the function of the IODs (overall technical complication rate: 0.37 treatments per patient per year (T/P/Y)), (Table 1). Technical complications occurred more frequently in group A (mean: 3.5 during observational time) than in the other two groups (B: 0.8: C: 1.0). However, this difference was not statistically significant (P=0.58, Fig. 2). The success rates (Kaplan-Meier) which represent the share of IODs that were functional without any clinical intervention are presented in Fig. 3. Peri-implantitis was diagnosed in 20 implants (12.4%), in 12 IODs (3 in the maxilla, 9 in the mandible) (A: 2; B: 9; C: 1) in 10 of 27 patients (37%). Six of the 10 smokers (60%) that participated in the study, and 4 of the 17 non-smokers (23.5%) were diagnosed with peri-implantitis (Fig. 4).
Table 1

Technical complications of implant-retained overdentures with 3 different bar designs

ComplicationBar design
Prefabricated round (n=7)Milled, anteriorly located (n=20)Milled, bilaterally placed (n=9)
Screw (loosening, fracture)310
Bar (fracture, retention/friction loss, TK Snap renewal)2253
Denture (crack/fracture repair, relining, tooth renewal)18117
Fig. 2

Number of technical complications according to the bar design (means with 95% confidence intervals) after a 7.3-year mean observation time.

Fig. 3

Success rates (Kaplan Meier analysis) of implant-retained overdentures with 3 different bar designs after a 7.3-year mean observation time.

Fig. 4

Distribution of peri-implantitis (red fraction) in non-smokers (4/17=23.5%) and smokers (6/10=60%).

DISCUSSION

The implant (97.7%) and prosthetic (100%) survival rates are similar to the findings reported by other studies.123 In literature, the requirements for prosthetic maintenance of IODs vary between 0.25 and 4.03 (T/P/Y).12310 The overall technical complication rate of 0.37 (T/P/Y) that was calculated in the present study is at the lower end of this range, it is similar to other studies that reported technical complications of bar-retained IODs.12 In the present study, IODs that were retained by milled bars exhibited rather lower but statistically insignificant rates of mechanical complications in comparison with IODs retained by prefabricated round bars. Nevertheless, this is similar to previous studies that reported lower technical complication rates for milled bars than that of prefabricated round bars.12 Krennmair et al.6 (2012) demonstrated high implant success rates and limited prosthodontic maintenance for rigid anchoring with milled bars or telescopic attachments. In this study, bar-related complications predominantly appeared for prefabricated round bars, whereas IODs retained by milled bars showed more denture-related complications. Bressan et al.14 (2012) also demonstrated mainly bar-related complications for IODs retained by round bars supported by two implants. Alternatively, Heschl et al.15 (2013) documented only limited complication rates for round bars supported by 4 implants with distal extensions. Other authors controversially discussed whether the number of implants and/or the use of extensions have an impact on the complication rates of IODs. Ueda et al.8 (2011) and Meijer et al.7 (2009) found no differences between IODs supported by 2 or 4 implants. However, Krennmair et al. (2007 & 2012) demonstrated prevention of non-axial overloading, posterior bone resorption or denture rotation for bar-structures rigidly retained by 4 implants.567 Moreover, up to now, the relevance of extensions regarding the complication rates of IODs seems indistinct. Placing cantilevers on bars was rated useful to offer adequate occlusal posterior support.4 However, Krennmaier et al.5 (2007) showed that distal extensions included in their bars affected neither the degree of distal bone loss nor the implant survival rate. Nevertheless, in the present study round bars on 2 implants without extensions offered higher complication rates than milled bars on 4 implants including distal extensions. In the present study, 12.4% of the implants in 37% of the patients exhibited radiographic symptoms of peri-implantitis. Studies using the same diagnostic criteria have reported implant-based peri-implantitis rates between 10.1-11.7%, and patient-based peri-implantitis rates of 9.2-10.0% for mean observational periods of 5.6-7 years.910 The bar design might explain the comparatively high peri-implantitis rates in the present study. It may lead to a reduced accessibility for oral hygiene procedures at home.10 IODs retained by milled bars exhibited significantly higher plaque index values than IODs retained by telescopic crowns.6 In the present study, especially massive one-piece milled bars in the mandible showed radiological symptoms of peri-implantitis (9 out of 20, however, the rates were not statistically significant). Abd El-Dayem et al.11 (2009) demonstrated less bone resorption for IODs supported by round bars compared to custom-made bars. In the present study, smoking patients exhibited a higher prevalence of peri-implantitis than non-smoking patients (60% vs. 23.5%), thus supporting data from previous studies suggesting that a smoking habit is a significant risk factor for the development of peri-implant diseases.9

CONCLUSION

Within the limitations of this study, we concluded that barretained IODs are an adequate treatment option for edentulous jaws. These restorations may exhibit high implant and prosthesis survival rates (>97%) and a limited incidence of technical complications after a mean observational period of >7 years. Nevertheless, peri-implantitis was identified as a frequent and serious biological complication for this type of reconstruction.
  15 in total

1.  The influence of bar design (round versus milled bar) on prosthodontic maintenance of mandibular overdentures supported by 4 implants: a 5-year prospective study.

Authors:  Gerald Krennmair; Martin Krainhöfner; Eva Piehslinger
Journal:  Int J Prosthodont       Date:  2008 Nov-Dec       Impact factor: 1.681

2.  Removable implant-supported maxillary prostheses anchored on milled bars: a retrospective evaluation of two concepts.

Authors:  Gerald Krennmair; Eva Piehslinger
Journal:  Int J Prosthodont       Date:  2009 Nov-Dec       Impact factor: 1.681

3.  Removable four implant-supported mandibular overdentures rigidly retained with telescopic crowns or milled bars: a 3-year prospective study.

Authors:  Gerald Krennmair; Daniel Sütö; Rudolf Seemann; Eva Piehslinger
Journal:  Clin Oral Implants Res       Date:  2011-04-19       Impact factor: 5.977

4.  Technical and biological complications of single-molar implant restorations.

Authors:  Sven Rinke; Matthias Roediger; Peter Eickholz; Katharina Lange; Dirk Ziebolz
Journal:  Clin Oral Implants Res       Date:  2014-03-27       Impact factor: 5.977

Review 5.  A systematic review of marginal bone loss around implants retaining or supporting overdentures.

Authors:  Murat Cavit Cehreli; Durdu Karasoy; Ali Murat Kökat; Kivanç Akça; Steven Eckert
Journal:  Int J Oral Maxillofac Implants       Date:  2010 Mar-Apr       Impact factor: 2.804

6.  Prevalence of periimplant disease in partially edentulous patients: a practice-based cross-sectional study.

Authors:  Sven Rinke; Susanne Ohl; Dirk Ziebolz; Katharina Lange; Peter Eickholz
Journal:  Clin Oral Implants Res       Date:  2010-12-28       Impact factor: 5.977

7.  The anterior cantilever in the implant-supported screw-retained mandibular prosthesis.

Authors:  M E Brosky; T W P Korioth; J Hodges
Journal:  J Prosthet Dent       Date:  2003-03       Impact factor: 3.426

8.  Double crown-retained maxillary overdentures: 5-year follow-up.

Authors:  Eberhard Frisch; Dirk Ziebolz; Petra Ratka-Krüger; Sven Rinke
Journal:  Clin Implant Dent Relat Res       Date:  2013-05-16       Impact factor: 3.932

9.  Implant-supported mandibular overdentures retained with a milled bar: a retrospective study.

Authors:  Gerald Krennmair; Martin Krainhöfner; Eva Piehslinger
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Nov-Dec       Impact factor: 2.804

10.  Mandibular overdentures supported by two or four endosseous implants: a 10-year clinical trial.

Authors:  Henny J A Meijer; Gerry M Raghoebar; Rutger H K Batenburg; Anita Visser; Arjan Vissink
Journal:  Clin Oral Implants Res       Date:  2009-03-27       Impact factor: 5.977

View more
  5 in total

1.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

2.  Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study.

Authors:  Hyun-Wook Woo; Sung-Am Cho; Cheong-Hee Lee; Kyu-Bok Lee; Jin-Hyun Cho; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

3.  Rehabilitation of an Extremely Edentulous Atrophic Maxilla with a Pseudoskeletal Class III Relationship.

Authors:  Gregor-Georg Zafiropoulos; Tae Ho Yoon; Moosa Abuzayda
Journal:  Case Rep Dent       Date:  2019-04-21

4.  Realization of a Dental Framework by 3D Printing in Material Cobalt-Chromium with Superior Precision and Fitting Accuracy.

Authors:  André Edelmann; Lisa Riedel; Ralf Hellmann
Journal:  Materials (Basel)       Date:  2020-11-27       Impact factor: 3.623

5.  Clinical outcomes of implant-retained mandibular overdentures using the bar and magnetic attachment systems: an up to 5-year retrospective study.

Authors:  Huan Zhou; Yang Jiao; Chu-Fan Ma; Chao Wang; San-Jun Zhao; Min Tian; Franklin R Tay; Ji-Hua Chen
Journal:  Ann Transl Med       Date:  2020-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.