| Literature DB >> 25664612 |
Jaana-Sophia Kern1, Thomas Kern1, Stefan Wolfart1, Nicole Heussen2.
Abstract
OBJECTIVES: The aim of this systematic review was to analyze post-loading implant loss for implant-supported prostheses in edentulous jaws, regarding a potential impact of implant location (maxilla vs. mandible), implant number per patient, type of prosthesis (removable vs. fixed), and type of attachment system (screw-retained, ball vs. bar vs. telescopic crown).Entities:
Keywords: edentulous mandible; edentulous maxilla; implant-supported prosthesis; meta-analysis; systematic review
Mesh:
Year: 2015 PMID: 25664612 PMCID: PMC5024059 DOI: 10.1111/clr.12531
Source DB: PubMed Journal: Clin Oral Implants Res ISSN: 0905-7161 Impact factor: 5.977
Search strategy
| Information sources | Electronic databases | PubMed, EMBASE, The Cochrane Library |
| Additional sources | German dental journals (not Medline listed), Private databases, reference lists | |
|
Search strategy | Population | #1: ((“mouth, edentulous”[MeSH Terms] OR (“mouth”[All Fields] AND “edentulous”[All Fields]) OR “edentulous mouth”[All Fields] OR “edentulous”[All Fields]) OR (completely[All Fields] AND (“mouth, edentulous”[MeSH Terms] OR (“mouth”[All Fields] AND “edentulous”[All Fields]) OR “edentulous mouth”[All Fields] OR “edentulous”[All Fields]))) AND (“maxilla”[MeSH Terms] OR “maxilla”[All Fields])) OR (“mandible”[MeSH Terms] OR “mandible”[All Fields])) AND (“dental implants”[MeSH Terms] OR (“dental”[All Fields] AND “implants”[All Fields]) OR “dental implants”[All Fields] OR (“dental”[All Fields] AND “implant”[All Fields]) OR “dental implant”[All Fields]) |
| Intervention | #2: #1 AND ((implant[All Fields] AND (“denture, overlay”[MeSH Terms] OR (“denture”[All Fields] AND “overlay”[All Fields]) OR “overlay denture”[All Fields] OR “overdenture”[All Fields])) OR (complete[All Fields] AND implant[All Fields] AND removable[All Fields] AND (“dental prosthesis”[MeSH Terms] OR (“dental”[All Fields] AND “prosthesis”[All Fields]) OR “dental prosthesis”[All Fields]))) OR (complete[All Fields] AND fixed[All Fields] AND (“dental prosthesis”[MeSH Terms] OR (“dental”[All Fields] AND “prosthesis”[All Fields]) OR “dental prosthesis”[All Fields]))) OR (full‐arch[All Fields] AND restoration[All Fields])) OR (“dental prosthesis, implant‐supported”[MeSH Terms] OR (“dental”[All Fields] AND “prosthesis”[All Fields] AND “implant‐supported”[All Fields]) OR “implant‐supported dental prosthesis”[All Fields] OR (“implant”[All Fields] AND “supported”[All Fields] AND “dental”[All Fields] AND “prosthesis”[All Fields]) OR “implant‐supported dental prosthesis”[All Fields])) | |
| Comparison | Covered by Population, Intervention and Outcome search | |
| Outcome | #3: #1 AND (“survival rate”[MeSH Terms] OR (“survival”[All Fields] AND “rate”[All Fields]) OR “survival rate”[All Fields]) | |
| Limits (filters) | Clinical trial, humans | |
| Period | No time restriction | |
|
Search strategy | “dental implant”/exp OR “dental implant” AND “edentulous” | |
| Limits (filters) | No | |
|
Search strategy | “dental implant AND edentulous” | |
| Limits (filters) | Trials |
Risk of bias within studies
| Studies in alphabetical order | Study design | Overall assessment of the study | Level of evidence | Sponsoring/support as reported by the authors |
|---|---|---|---|---|
| Agliardi et al. ( | Prospective | + | 2+ | n.r. |
| Akca et al. ( | Prospective | + | 2+ | Partly supported by State Planning Organization, Prime Ministry, Republic of Turkey |
| Akoglu et al. ( | Prospective | ++ | 2++ | n.r. |
| Arvidson et al. ( | Prospective | + | 2+ | n.r. |
| Arvidson et al. ( | Prospective | ++ | 2++ | Supported and sponsored by Institut Straumann AG, Basel, Switzerland |
| Behneke et al. ( | Prospective | + | 2+ | n.r. |
| Bergendal & Engquist ( | Prospective | + | 2+ | n.r. |
| Cehreli et al. ( | RCT | + | 1+ |
Partly supported by the State Planning |
| Chiapasco & Gatti ( | Prospective | + | 2+ | n.r. |
| Collaert & De Bruyn ( | Prospective | + | 2+ | n.r. |
| Cooper et al. ( | Prospective | ++ | 2++ | n.r. |
| Cordioli et al. ( | Prospective | + | 2+ | n.r. |
| Covani et al. ( | Prospective | + | 2+ | n.r. |
| Crespi et al. ( | Prospective | + | 2+ | n.r. |
| De Bruyn et al. ( | Prospective | + | 2+ | n.r. |
| De Santis et al. ( | Prospective | + | 2+ | n.r. |
| Degidi et al. ( | Prospective | + | 2+ | n.r. |
| Ekelund et al. ( | Prospective | + | 2+ | n.r. |
| Eliasson et al. ( | Prospective, randomized | + | 2+ | Supported by a grant from Public Dental Health, Örebro County Council, Sweden |
| Elsyad et al. ( | RCT | + | 1+ | n.r. |
| Engquist et al. ( | Prospective, controlled | ++ | 2++ | n.r. |
| Fischer & Stenberg ( | Prospective | + | 2+ | Institut Straumann AG, Basel, Switzerland assisted to prepare the manuscript |
| Gotfredsen & Holm ( | Prospective, randomized | + | 2+ | Astra Tech, Sweden supplied implants and implant components |
| Harder et al. ( | Prospective | + | 2+ | Supported by a grant from Camlog Biotechnologies AG, Basel, Switzerland |
| Heijdenrijk et al. ( | Prospective, randomized | + | 2+ | n.r. |
| Heschl et al. ( | Prospective | + | 2+ | n.r. |
| Jemt et al. ( | Prospective | + | 2+ | Nobelpharma AB, Göteborg, Sweden supported with components |
| Krennmair et al. ( | Prospective, randomized | ++ | 2++ | Study was self‐funded by the authors and their institution |
| Krennmair et al. ( | Prospective, randomized | ++ | 2++ | n.r. |
| Krennmair et al. ( | Prospective, randomized | ++ | 2++ | Study was self‐funded by the authors and their institution |
| Lethaus et al. ( | Prospective | + | 2+ | Supported and sponsored by Institut Straumann, Basel, Switzerland |
| Liddelow & Henry ( | Prospective | + | 2+ | n.r. |
| Lorenzoni et al. ( | Prospective | + | 2+ | n.r. |
| Meijer et al. ( | RCT | + | 1+ | n.r. |
| Meijer et al. ( | Prospective | + | 2+ | n.r. |
| Meijer et al. ( | Prospective | + | 2+ | n.r. |
| Mertens et al. ( | Prospective | + | 2+ | Supported by Astra Tech AB, Sweden and Bioscientia, Germany, provided kits for IL‐1 composite genotype tests |
| Murphy et al. ( | Prospective | + | 2+ | n.r. |
| Naert et al. ( | Prospective | + | 2+ | Ceka NV, Belgium, support with prosthesis components |
| Nyström et al. ( | Prospective | + | 2+ | n.r. |
| Nyström et al. ( | Prospective | + | 2+ | n.r. |
| Örtorp & Jemt ( | Prospective | + | 2+ | Supported by Wilhelm and Martina Lundgren Research Foundation |
| Rasmusson et al. ( | Prospective | + | 2+ | n.r. |
| Richter & Knapp ( | Prospective | + | 2+ | Biomet 3i supported the study with implants and implant components |
| Romeo et al. ( | Prospective | + | 2+ | n.r. |
| Schwarz et al. ( | Prospective | + | 2+ | Financially supported by FRIADENT GmbH, Germany |
| Sjöström et al. ( | Prospective | + | 2+ | n.r. |
| Stoker et al. ( | RCT | + | 1+ | Supported by a grant (188/2000) from the ITI Foundation for the Promotion of Oral Implantology, Switzerland |
| Testori et al. ( | Prospective | + | 2+ | n.r. |
| Van de Velde et al. ( | Prospective | + | 2+ | n.r. |
| Vroom et al. ( | Prospective | + | 2+ | Partly supported by Astra Tech AB, Sweden |
| Weinländer et al. ( | Prospective | + | 2+ | Study was self‐funded by the authors and their institution |
| Zitzmann & Marinello ( | Prospective | + | 2+ | n.r. |
| Zou et al. ( | Prospective | + | 2+ |
Funded by Combined Engineering and Medical Project of Shanghai Jiao Tong University the National Natural Science Foundation of (YG2010MS56), Science and Technology Commission of Shanghai Municipality (13ZR1424000), China (81100788, 31370983, 81371190), the Key Project of Chinese |
How well was the study performed to minimize the risk of bias or confounding? (++) High quality (+) Acceptable (−) Low quality.
Level of evidence according to SIGN: 1+ = well‐conducted meta‐analyses, systematic reviews, or RCTs with a low risk of bias; 2++ = high‐quality systematic reviews of case–control or cohort studies, high‐quality case–control or cohort studies with a very low risk of confounding or bias and a high probability that the relationship is causal. 2+ = well‐conducted case–control or cohort studies with a low risk of confounding or bias and a moderate probability that the relationship is causal; 2− = case–control or cohort studies with a high risk of confounding or bias and a significant risk that the relationship is not causal; 3 = Non‐analytic studies, for example case reports, case series.
Study characteristics according to jaw
| Study (Year of publication) | Study design | Jaw | Type of prosthesis | Type of anchorage | Implant system (as reported by the authors) | Loading protocol | Total number of implants | Total number of prostheses | Follow‐up period (years) |
|---|---|---|---|---|---|---|---|---|---|
| Agliardi et al. ( | Prospective | Maxilla | Fixed | Screw‐retained | Brånemark, Nobel Speedy (Nobel Biocare) | Immediate | 192 | 32 | 4.6 |
| Collaert & De Bruyn ( | Prospective | Maxilla | Fixed | Screw‐retained | TiOblast Astra Tech (Dentsply) | Immediate | 195 | 25 | 3 |
| De Santis et al. ( | Prospective | Maxilla | Fixed | Screw‐retained | n.a. | Conventional | 154 | 20 | 4.3 |
| Degidi et al. ( | Prospective | Maxilla | Fixed | Screw‐retained | Xive (Dentsply) | Immediate | 210 | 30 | 3 |
| Fischer & Stenberg ( | Prospective | Maxilla | Fixed | Screw‐retained | Esthetic Plus SLA (Straumann) | Immediate/conventional | 142 | 24 | 10 |
| Mertens et al. ( | Prospective | Maxilla | Fixed | Screw‐retained | Astra Tech, Dentsply | Conventional | 106 | 17 | 11.3 |
| Naert et al. ( | Prospective | Maxilla | Fixed | Screw‐retained | Brånemark (Nobel Biocare) | Conventional | 53 | 13 | 3 |
| Nyström et al. ( | Prospective | Maxilla | Fixed | Screw‐retained | Brånemark (Nobel Biocare) | Conventional | 167 | 26 | 13 |
| Nyström et al. ( | Prospective | Maxilla | Fixed | Screw‐retained | Brånemark (Nobel Biocare) | Conventional | 334 | 44 | 11 |
| Richter & Knapp ( | Prospective | Maxilla | Removable | Telescopic crown, locator | Osseotite (Biomet 3i) | Conventional | 44 | 27 | 5 |
| Sjöström et al. ( | Prospective | Maxilla | Fixed | Screw‐retained | Brånemark (Nobel Biocare) | Conventional | 222 | 29 | 3 |
| Zitzmann & Marinello ( | Prospective | Maxilla | Fixed | Screw‐retained | Brånemark (Nobel Biocare) | Conventional | 84 | 10 | 3.3 |
| Zou et al. ( | Prospective | Maxilla | Removable | Telescopic crown, bar, locator | ITI (Straumann) | Conventional | 120 | 30 | 3 |
| Akoglu et al. ( | Prospective | Mandible | Removable | Ball | ITI (Straumann), Swiss Plus (Zimmer Dental), Astra Tech (Dentsply) | Conventional | 72 | 36 | 5 |
| Arvidson et al. ( | Prospective | Mandible | Fixed | Screw‐retained | Astra Tech (Dentsply) | Conventional | 618 | 107 | 5 |
| Arvidson et al. ( | Prospective, multicenter | Mandible | Fixed | Screw‐retained | ITI Monotype SLA (Straumann) | Early | 250 | 61 | 3 |
| Behneke et al. ( | Prospective | Mandible | Removable | Bar | ITI (Straumann) | Conventional | 340 | 100 | 5.8 |
| Cehreli et al. ( | RCT | Mandible | Removable | Ball | SLA (Straumann), Brånemark TiUnite (Nobel Biocare) | Early | 56 | 28 | 5 |
| Chiapasco & Gatti ( | Prospective | Mandible | Removable | Bar | Ha‐Ti (Mathys Dental), ITI (Straumann), Brånemark Conical (Nobel Biocare), Frialoc (Dentsply) | Immediate | 328 | 82 | 5.2 |
| Cooper et al. ( | Prospective | Mandible | Removable | Ball | Friatec (Dentsply) | Conventional | 118 | 59 | 5 |
| Cordioli et al. ( | Prospective | Mandible | Removable | Ball | Biomet 3i | Conventional | 21 | 21 | 5 |
| De Bruyn et al. ( | Prospective | Mandible | Fixed | Screw‐retained | TiOblast Astra Tech (Dentsply) | Immediate | 125 | 25 | 3 |
| Ekelund et al. ( | Prospective | Mandible | Fixed | Screw‐retained | Standard Brånemark (Nobel Biocare) | Conventional | 273 | 47 | 21.5 |
| Eliasson et al. ( | Prospective, randomized | Mandible | Fixed | Screw‐retained | Paragon TPS (Zimmer Dental) | Conventional | 168 | 29 | 5 |
| Elsyad et al. ( | RCT | Mandible | Removable | Ball | Spectra System Screw Plant (Implant Direct LLC) | Immediate/conventional | 72 | 36 | 3 |
| Engquist et al. ( | Prospective, controlled | Mandible | Fixed | Screw‐retained | Standard Brånemark, Brånemark conical 1‐piece, Brånemark Mk II (Nobel Biocare) | Early/conventional | 432 | 108 | 3 |
| Gotfredsen & Holm ( | Prospective, randomized | Mandible | Removable | Bar, ball | Astra Tech (Dentsply) | Conventional | 52 | 26 | 5 |
| Harder et al. ( | Prospective | Mandible | Removable | Ball | Camlog Promote screw line (Camlog) | Conventional | 11 | 11 | 3.6 |
| Heijdenrijk et al. ( | Prospective, randomized | Mandible | Removable | Bar | IMZ TPS, solid screw TPS (Straumann) | Conventional | 120 | 60 | 5 |
| Heschl et al. ( | Prospective | Mandible | Removable | Bar | Xive S plus (Dentsply) | Conventional | 156 | 39 | 5 |
| Krennmair et al. ( | Prospective, randomized | Mandible | Removable | Bar | IMZ (Dentsply), Frialoc (Dentsply), Camlog root line (Camlog) | Conventional | 204 | 51 | 5 |
| Krennmair et al. ( | Prospective, randomized | Mandible | Removable | Ball, telescopic crown | Camlog root line (Camlog) | Conventional | 50 | 25 | 5 |
| Krennmair et al. ( | Prospective, randomized | Mandible | Removable | Bar, telescopic crown | Camlog root line/screw line (Camlog) | Conventional | 204 | 51 | 3 |
| Lethaus et al. ( | Prospective | Mandible | Removable | Bar | SLA (Straumann) | Early | 70 | 14 | 5 |
| Liddelow & Henry ( | Prospective | Mandible | Removable | Ball | Brånemark Mk III TiUnite, Brånemark Mk III machined (Nobel Biocare) | Immediate | 32 | 32 | 3 |
| Lorenzoni et al. ( | Prospective | Mandible | Removable | Bar | Xive S Plus (Dentsply) | Immediate/conventional | 160 | 40 | 5 |
| Meijer et al. ( | RCT | Mandible | Removable | Bar | IMZ (Dentsply), Brånemark (Nobel Biocare) | Conventional | 122 | 61 | 10 |
| Meijer et al. ( | Prospective | Mandible | Removable | Bar | IMZ TPS (Dentsply), Brånemark (Nobel Biocare), ITI solid screw TPS (Straumann) | Conventional | 180 | 90 | 10 |
| Meijer et al. ( | Prospective | Mandible | Removable | Bar | IMZ TPS (Dentsply) | Conventional | 180 | 60 | 10 |
| Murphy et al. ( | Prospective | Mandible | Fixed | Screw‐retained | Astra Tech (Dentsply) | Conventional | 131 | 26 | 5 |
| Schwarz et al. ( | Prospective | Mandible | Fixed | Screw‐retained | Frialoc (Dentsply) | Early | 158 | 37 | 4.5 |
| Stoker et al. ( | RCT | Mandible | Removable | n.a. | 1‐stage TPS Bonefit (Straumann) | Conventional | 296 | 110 | 8.3 |
| Testori et al. ( | Prospective | Mandible | Fixed | Screw‐retained | Osseotite, dual acid‐etched, cylindrical, screw‐shaped (3i) | Immediate | 116 | 19 | 3.2 |
| Van de Velde et al. ( | Prospective | Mandible | Fixed | Screw‐retained | Brånemark Mk III/Mk IV (Nobel Biocare) | Immediate | 91 | 18 | 3.8 |
| Vroom et al. ( | Prospective | Mandible | Removable | Bar | Astra Tech turned/tioblasted (Dentsply) | Conventional | 80 | 20 | 12 |
| Weinländer et al. ( | Prospective | Mandible | Removable | Bar | IMZ cylindric, Frialoc (Denstply), Camlog screw line (Camlog) | Conventional | 252 | 76 | 5 |
| Akca et al. ( | Prospective | Both jaws | Removable | Bar | ITI SLA/TPS (Straumann) | Conventional | 124 | 35 | 4.9 |
| Bergendal & Engquist ( | Prospective | Both jaws | Removable | Bar, ball | Brånemark (Nobel Biocare) | Conventional | 115 | 50 | 5.2 |
| Covani et al. ( | Prospective | Both jaws, only maxilla included | Fixed | Screw‐retained | Ossean (Intra Lock Int) | Immediate | 128 | 16 | 3.6 |
| Crespi et al. ( | Prospective | Both jaws | Fixed | Screw‐retained | PAD system (Sweden‐Martina) | Immediate | 176 | 44 | 3 |
| Jemt et al. ( | Prospective | Both jaws | Removable | Bar | Brånemark (Nobel Biocare) | Conventional | 315 | 133 | 5 |
| Örtorp & Jemt ( | Prospective | Both jaws | Fixed | Screw‐retained | Brånemark (Nobel Biocare) | Conventional | 728 | 129 | 10 |
| Rasmusson et al. ( | Prospective | Both jaws | Fixed | Screw‐retained | TiOblast Astra Tech (Denstply) | Conventional | 199 | 36 | 10 |
| Romeo et al. ( | Prospective | Both jaws | Removable | n.a. | ITI SLA/TPS (Straumann) | Conventional | 126 | 37 | 3.9 |
Estimated implant loss rate and corresponding implant survival for edentulous maxillae with fixed and removable prostheses categorized by number of implants per patient
| Study | Subgroups within study | Number of implants per patient | Total number of implants | Type of prosthesis and anchorage | Number of post‐loading implant losses | Total implant exposure time (implant years) | Estimated implant loss (per 100 implant years) | Estimated implant survival after 5 years (%) |
|---|---|---|---|---|---|---|---|---|
| Richter & Knapp | Locator | <4 | 14 | Removable, BL | 12 | 43.1 | 27.8 | 24.6 |
| Telescopic crowns | <4 | 30 | Removable, TC | 18 | 119.5 | 15.1 | 47.1 | |
| Bergendal & Engquist | Bar | <4 | 29 | Removable, BR | 6 | 140.3 | 4.3 | 80.7 |
| Ball | <4 | 18 | Removable, BL | 7 | 88.0 | 8.0 | 67.2 | |
| Romeo et al. | n.a. | <4 | 42 | Removable | 246.0 | 1.2 | 94.1 | |
| Naert et al. | n.a. | 4 | 53 | Removable, BR | 3 | 135.9 | 2.21 | 89.4 |
| Akca et al. | n.a. | 4 | 44 | Removable, BR | 1 | 210.7 | 0.5 | 97.6 |
| Crespi et al. | n.a. | 4 | 96 | Fixed, SR | 1 | 285.3 | 0.35 | 98.3 |
| Jemt/Watson et al. | n.a. | 4 | 117 | Removable, BR | 21 | 375.5 | 5.6 | 75.0 |
| Zou et al. | Telescopic crowns | 4 | 40 | Removable, TC | 0 | 120.0 | 0 | 100 |
| Bar | 4 | 40 | Removable, BR | 0 | 120.0 | 0 | 100 | |
| Locator | 4 | 40 | Removable, BL | 0 | 120.0 | 0 | 100 | |
| Agliardi et al. | n.a. | ≥6 | 192 | Fixed, SC | 0 | 576.0 | 0 | 100 |
| Fischer & Stenberg | n.a. | 5–6 | 142 | Fixed, SC | 4 | 1095.0 | 0.4 | 98.2 |
| Rasmusson et al. | n.a. | 5–6 | 91 | Fixed, SC | 0 | 787.0 | 0 | 100 |
| Collaert & De Bruyn | n.a. | ≥6 | 195 | Fixed, SC | 0 | 529.0 | 0 | 100 |
| De Santis et al. | n.a. | ≥6 | 154 | Fixed, SC | 0 | 780.0 | 0 | 100 |
| Degidi et al. | n.a. | ≥6 | 210 | Fixed, SC | 1 | 630.1 | 0.2 | 99.1 |
| Mertens et al. | n.a. | ≥6 | 106 | Fixed, SC | 2 | 1050.9 | 0.2 | 99.1 |
| Nytröm et al. | n.a. | ≥6 | 167 | Fixed, SC | 5 | 2132.0 | 0.2 | 98.8 |
| Nyström et al. | n.a. | ≥6 | 334 | Fixed, SC | 4 | 3674.0 | 0.1 | 99.5 |
| Sjöström et al. | n.a. | ≥6 | 222 | Fixed, SC | 8 | 197.5 | 4.1 | 81.3 |
| Zitzmann & Marinello | n.a. | ≥6 | 84 | Fixed, SC | 0 | 820.0 | 0 | 100 |
| Covani et al. | n.a. | ≥6 | 128 | Fixed, SC | 0 | 460.8 | 0 | 100 |
| Örtorp et al. | n.a. | ≥6 | 355 | Fixed, SC | 17 | 2042.5 | 0.8 | 95.9 |
BL, ball; BR, bar; TC, telescopic crown; SC, screw‐retained; n.a., not applicable.
This category was excluded from further statistical analysis.
Figure 1Modified PRISMA flow chart: study selection process. *zygoma, pterygomaxillary, transmandibular or other region, no clinical examination/no regular follow‐up, observation <3 year, no titanium implant, no clinical study, not edentulous, retrospective/study design unclear, no separate reporting of edentulous jaws/removable or fixed prostheses, same patient cohort at earlier stage, case report, no survival rate nor implant loss, different emphasis, study being judged with “2−” according to SIGN (high risk of bias)
Estimated implant loss rate and corresponding implant survival for edentulous mandible with fixed and removable prostheses categorized by number of implants per patient
| Study | Subgroups within study | Number of implants per patient | Total number of implants* | Type of prosthesis and anchorage | Number of post‐loading implant losses | Total implant exposure time (implant years) | Estimated implant loss (per 100 implant years) | Estimated implant survival after 5 years (%) |
|---|---|---|---|---|---|---|---|---|
| Cordioli et al. | n.a. | 1 | 21 | Removable, BL | 0 | 95.0 | 0 | 100 |
| Harder et al. | n.a. | 1 | 11 | Removable, BL | 0 | 38.9 | 0 | 100 |
| Liddelow et al. | Machined | 1 | 7 | Removable, BL | 3 | 12.4 | 24.2 | 25.1 |
| Rough | 1 | 25 | Removable, BL | 0 | 36.5 | 0 | 100 | |
| Akoglu et al. | n.a. | 2 | 72 | Removable, BL | 0 | 360.0 | 0 | 100 |
| Cehreli et al. | n.a. | 2 | 56 | Removable, BL | 0 | 230.0 | 0 | 100 |
| Cooper et al. | n.a. | 2 | 118 | Removable, BL | 0 | 557.0 | 0 | 100 |
| Elsyad et al. | Immed. load. | 2 | 36 | Removable, BL | 0 | 96.0 | 0 | 100 |
| Convent. load. | 2 | 36 | Removable, BL | 4 | 92.3 | 4.3 | 80.1 | |
| Gotfredsen & Holm | Bar | 2 | 22 | Removable, BL | 0 | 110.0 | 0 | 100 |
| Ball | 2 | 30 | Removable, BL | 0 | 148.0 | 0 | 100 | |
| Heijdenrijk et al. | 1‐stage | 2 | 40 | Removable, BL | 0 | 381.1 | 0 | 100 |
| 2‐stage | 2 | 80 | Removable, BL | 2 | 192.0 | 1.0 | 94.9 | |
| Krennmair et al. | Ball | 2 | 26 | Removable, BL | 0 | 122.0 | 0 | 100 |
| Telesc. crowns | 2 | 24 | Removable, TC | 0 | 108.0 | 0 | 100 | |
| Meijer et al. | IMZ | 2 | 58 | Removable, BR | 1 | 560.0 | 0.2 | 99.1 |
| Brå | 2 | 64 | Removable, BR | 4 | 536.0 | 0.7 | 96.3 | |
| Meijer et al. | Brå | 2 | 60 | Removable, BR | 0 | 546.0 | 0 | 100 |
| IMZ | 2 | 60 | Removable, BR | 3 | 570.0 | 0.5 | 97.4 | |
| ITI Str | 2 | 60 | Removable, BR | 0 | 562.0 | 0 | 100 | |
| Meijer et al. | 2 implants | 2 | 60 | Removable, BR | 3 | 1008.5 | 0.3 | 98.5 |
| Weinländer et al. | 2 implants | 2 | 48 | Removable, BR | 0 | 216.0 | 0 | 100 |
| Jemt et al./Watson et al. | n.a. | 2 | 198 | Removable, BR | 7 | 880.0 | 0.8 | 96.1 |
| Behneke et al. | n.a. | 2‐4 | 340 | Removable, BR | 0 | 1530.0 | 0 | 100 |
| Stoker et al. | n.a. | 2‐4 | 296 | Removable, n.a. | 9 | 2124.8 | 0.4 | 97.9 |
| Akca et al. | n.a. | 2‐4 | 80 | Removable, BR | 1 | 392.0 | 0.3 | 98.7 |
| Bergendal & Engquist | Bar | 2‐4 | 39 | Removable, BR | 0 | 187.8 | 0 | 100 |
| Ball | 2‐4 | 29 | Removable, BL | 0 | 140.6 | 0 | 100 | |
| Romeo et al. | n.a. | 2‐4 | 84 | Removable, n.a. | 2 | 472.0 | 0.4 | 97.9 |
| Chiapasco et al. | n.a. | 4 | 328 | Removable, BR | 7 | 1704.0 | 0.4 | 98.0 |
| Engquist et al. | 1‐stage Brå/Str | 4 | 120 | Fixed, SC | 3 | 331.0 | 0.9 | 95.6 |
| 2‐stage Brå/Str | 4 | 120 | Fixed, SC | 0 | 347.0 | 0 | 100 | |
| 1‐stage Brå 1‐piece | 4 | 88 | Fixed, SC | 1 | 243.0 | 0.4 | 98.0 | |
| 1‐stage Brå Mk III | 4 | 104 | Fixed, SC | 7 | 299.0 | 2.3 | 88.8 | |
| Heschl et al. | n.a. | 4 | 156 | Removable, BR | 1 | 745.0 | 0.1 | 99.3 |
| Krennmair et al. | n.a. | 4 | 204 | Removable, BR | 0 | 768.0 | 0 | 100 |
| Krennmair et al. | Bar | 4 | 104 | Removable, BR | 0 | 296.0 | 0 | 100 |
| Telesc. crown | 4 | 100 | Removable, TC | 0 | 276.0 | 0 | 100 | |
| Lorenzoni et al. | Convent. load. | 4 | 80 | Removable, BR | 0 | 400.0 | 0 | 100 |
| Immed. load. | 4 | 80 | Removable, BR | 0 | 400.0 | 0 | 100 | |
| Meijer et al. | n.a. | 4 | 120 | Removable, BR | 0 | 586.3 | 0 | 100 |
| Vroom et al. | n.a. | 4 | 80 | Removable, BR | 0 | 852.0 | 0 | 100 |
| Weinländer et al. | n.a. | 4 | 204 | Removable, BR | 0 | 944.0 | 0 | 100 |
| Crespi et al. | n.a. | 4 | 80 | Fixed, SC | 2 | 273.6 | 0.7 | 96.4 |
| Arvidson et al. | n.a. | 4‐6 | 618 | Fixed, SC | 0 | 2809.0 | 0 | 100 |
| Arvidson et al. | n.a. | 4 | 250 | Fixed, SC | 3 | 511.3 | 0.6 | 97.1 |
| De Bruyn et al. | n.a. | ≥5 | 125 | Fixed, SC | 0 | 350.0 | 0 | 100 |
| Ekelund et al./Lindquist et al. | n.a. | ≥5 | 273 | Fixed, SC | 1 | 4835.0 | 0.02 | 99.9 |
| Eliasson | n.a. | ≥5 | 168 | Fixed, SC | 0 | 756.0 | 0 | 100 |
| Lethaus et al. | n.a. | ≥5 | 70 | Removable, BR | 0 | 286.0 | 0 | 100 |
| Murphy et al. | n.a. | ≥5 | 131 | Fixed, SC | 0 | 635.0 | 0 | 100 |
| Schwarz et al. | n.a. | ≥5 | 158 | Fixed, SC | 7 | 693.3 | 1.0 | 95.1 |
| Testori et al. | n.a. | ≥5 | 116 | Fixed, SC | 3 | 284.4 | 1.1 | 94.8 |
| Van de Velde et al. | n.a. | 4–6 | 91 | Fixed, SC | 3 | 302.4 | 1.0 | 95.1 |
| Örtorp et al. | n.a. | ≥5 | 373 | Fixed, SC | 0 | 2200.0 | 0 | 100 |
| Rasmusson et al. | n.a. | ≥5 | 108 | Fixed, SC | 0 | 1054.0 | 0 | 100 |
BL, ball; BR, bar; TC, telescopic crown; SC, screw‐retained; n.a., not applicable.
Overall comparison
Overall comparison bar vs. ball vs. telescopic crown (category <4 implants excluded)
| Number of study populations | Number of patients | Number of implants | Total number of post‐loading implant losses | Total exposure time (implant years) | Estimated loss rate per 100 implant years [95% CI] | Estimated 3‐year implant survival (%) [95% CI] | Estimated 5‐year implant survival (%) [95% CI] |
| |
|---|---|---|---|---|---|---|---|---|---|
| Ball | 13 | 267 | 507 | 7 | 2048.73 | 0.34 [0.16; 0.72] | 98.98 [97.87; 99.51] | 98.31 [96.46; 99.20] | |
| Bar | 28 | 928 | 2777 | 54 | 15494.73 | 0.35 [0.27; 0.46] | 98.96 [98.64; 99.20] | 98.27 [97.73; 98.66] | 0.9607 |
| Telescopic crown | 3 | 47 | 164 | 0 | 504.0 | Not estimable | |||
| Bar | 28 | 928 | 2777 | 54 | 15494.73 | 0.35 [0.27; 0.46] | 98.96 [98.64; 99.20] | 98.27 [97.73; 98.66] | |
| Ball | 13 | 267 | 507 | 7 | 2048.73 | 0.34 [0.16; 0.72] | 98.98 [97.87; 99.51] | 98.31 [96.46; 99.20] | |
| Telescopic crown | 3 | 47 | 164 | 0 | 504.0 | Not estimable | |||
Comparison in the maxilla
| Number of study populations | Number of patients | Number of implants | Number of post‐loading implant losses | Total exposure time (implant years) | Estimated loss rate per 100 implant years [95% CI] | Estimated 3‐year implant survival (%) [95% CI] | Estimated 5‐year implant survival (%) [95% CI] |
| |
|---|---|---|---|---|---|---|---|---|---|
| Fixed vs. removable prostheses (category <4 implants excluded) | |||||||||
| removable | 6 | 84 | 334 | 25 | 1082.10 | 2.31 [1.56; 3.42] | 93.30 [98.91; 99.41] | 89.09 [84.28; 92.50] | |
| fixed | 14 | 363 | 2383 | 42 | 15060.08 | 0.28 [0.21; 0.38] | 99.17 [98.87; 99.38] | 98.62 [98.13; 98.97] | <0.0001 |
| Removable: <4 implants vs. 4 implants | |||||||||
| <4 | 5 | 49 | 133 | 46 | 636.90 | 7.22 [5.41; 9.64] | 80.52 [74.88; 85.02] | 69.70 [61.75; 76.30] | |
| 4 | 6 | 84 | 334 | 25 | 1082.10 | 2.31 [1.56; 3.42] | 93.30 [90.25; 95.42] | 89.09 [84.29; 92.50] | <0.0001 |
| Fixed: ≥6 (no comparison feasible) | |||||||||
| ≥6 | 11 | 303 | 2057 | 37 | 13099.78 | 0.28 [0.20; 0.39] | 99.16 [98.84; 99.39] | 98.60 [98.07; 98.98] | |
Comparison in the mandible
| Number of study populations | Number of patients | Number of implants | Total number of post‐loading implant losses | Total exposure time (implant years) | Estimated loss rate per 100 implant years [95% CI] | Estimated 3‐year implant survival (%) [95% CI] | Estimated 5‐year implant survival (%) [95% CI] |
| |
|---|---|---|---|---|---|---|---|---|---|
| Fixed vs. removable prostheses | |||||||||
| Removable | 40 | 1280 | 3494 | 47 | 19562.16 | 0.24 [0.18; 0.32] | 99.28 [99.05; 99.46] | 98.81 [98.41; 99.10] | |
| Fixed | 16 | 592 | 2923 | 30 | 15924.04 | 0.19 [0.13; 0.27] | 99.44 [99.20; 99.61] | 99.06 [98.66; 99.34] | 0.2980 |
| Fixed: 4 implants vs. ≥5implants | |||||||||
| 4 | 6 | 189 | 762 | 16 | 2004.85 | 0.80 [0.49;1.30] | 97.63 [96.17; 98.54] | 96.10 [93.69; 97.59] | |
| ≥5 | 8 | 278 | 1452 | 11 | 10807.77 | 0.10 [0.06;0.18] | 99.70 [99.45; 99.83] | 99.49 [99.10; 99.72] | <0.0001 |
| Removable: 1 implant vs. 2 implants | |||||||||
| 1 | 4 | 66 | 66 | 3 | 182.81 | 1.64 [0.53; 5.09] | 95.20 [85.84; 98.42] | 92.13 [77.53; 97.38] | |
| 2 | 19 | 557 | 1134 | 24 | 7274.90 | 0.33 [0.22; 0.49] | 99.02 [98.53; 99.34] | 98.36 [97.58; 98.91] | 0.0088 |
| Removable: 2 implants vs. 4 implants | |||||||||
| 2 | 19 | 557 | 1134 | 24 | 7274.90 | 0.33 [0.22; 0.49] | 99.02 [98.53; 99.34] | 98.36 [97.58; 98.91] | |
| 4 | 10 | 365 | 1366 | 8 | 6971.25 | 0.11 [0.06; 0.23] | 99.66 [99.31; 99.82] | 99.45 [98.86; 99.70] | 0.0097 |
| 4 Implants: fixed vs. removable | |||||||||
| removable | 10 | 365 | 1366 | 8 | 6971.25 | 0.11 [0.06; 0.23] | 99.66 [99.31; 99.82] | 99.43 [98.86; 99.70] | |
| fixed | 6 | 189 | 762 | 16 | 2004.85 | 0.79 [0.49; 1.30] | 97.63 [96.17; 98.54] | 96.10 [93.69; 97.59] | <0.0001 |
Comparison bar vs. ball vs. telescopic crown for mandible
| Number of study populations | Number of patients | Number of implants | Total number of post‐loading implant losses | Total exposure time (implant years) | Estimated loss rate per 100 implant years [95% CI] | Estimated 3‐year implant survival (%) [95% CI] | Estimated 5‐year implant survival (%) [95% CI] |
| |
|---|---|---|---|---|---|---|---|---|---|
| Ball | 13 | 257 | 467 | 7 | 2048.73 | 0.34 [0.16; 0.72] | 98.98 [97.87; 99.51] | 98.31 [96.46; 99.20] | |
| Bar | 24 | 864 | 2523 | 29 | 14652.63 | 0.20 [0.14; 0.28] | 99.41 [99.15; 99.59] | 99.01 [98.61; 99.30] | 0.1499 |
| Telescopic crown | 2 | 37 | 124 | 0 | 384.0 | Not estimable | |||
| Bar | 24 | 864 | 2523 | 29 | 14652.63 | 0.20 [0.14; 0.28] | 99.41 [99.15; 99.59] | 99.01 [98.61; 99.30] | |
| Ball | 13 | 257 | 467 | 7 | 2048.73 | 0.34 [0.16; 0.72] | 98.98 [97.87; 99.51] | 98.31 [96.46; 99.20] | |
| Telescopic crown | 2 | 37 | 124 | 0 | 384.0 | Not estimable | |||
Machined implant surface vs. rough implant surface (category <4 implants excluded)
| Number of study populations | Number of patients | Number of implants | Total number of post‐loading implant losses | Total exposure time (implant years) | Estimated loss rate per 100 implant years [95% CI] | Estimated 3‐year implant survival (%) [95% CI] | Estimated 5‐year implant survival (%) |
| |
|---|---|---|---|---|---|---|---|---|---|
| Overall comparison | |||||||||
| Machined | 21 | 657 | 2888 | 87 | 21089.63 | 0.41 [0.33; 0.51] | 98.77 [98.48; 99.00] | 97.63 [97.09; 98.02] | |
| Rough | 53 | 1662 | 6246 | 57 | 29123.75 | 0.20 [0.15; 0.25] | 99.41 [99.24; 99.55] | 99.03 [98.74; 99.25] | <0.0001 |
| Fixed (maxilla and mandible) | |||||||||
| Machined | 12 | 393 | 2240 | 49 | 17423.42 | 0.28 [0.21; 0.37] | 99.16 [98.89; 99.36] | 98.17 [97.67; 98.56] | |
| Rough | 16 | 536 | 1714 | 23 | 12145.70 | 0.19 [0.13; 0.28] | 99.43 [99.15; 99.62] | 99.06 [98.59; 99.37] | 0.1177 |
| Removable (maxilla and mandible) | |||||||||
| Machined | 9 | 264 | 648 | 38 | 3666.21 | 1.04 [0.75; 1.42] | 96.94 [95.82; 97.76] | 94.93 [93.15; 96.32] | |
| Rough | 37 | 1059 | 3180 | 34 | 16978.05 | 0.20 [0.14; 0.28] | 99.40 [99.16; 99.57] | 99.01 [98.61; 99.30] | <0.0001 |
| Maxilla (fixed and removable) | |||||||||
| Machined | 7 | 163 | 1162 | 58 | 9377.40 | 0.62 [0.48; 0.80] | 98.16 [97.63; 98.58] | 96.95 [96.08; 97.64] | |
| Rough | 12 | 241 | 1385 | 9 | 5984.78 | 0.15 [0.08; 0.29] | 99.55 [99.14; 99.77] | 99.25 [98.57; 99.61] | <0.0001 |
| Mandible (fixed and removable) | |||||||||
| Machined | 13 | 451 | 1556 | 29 | 11712.23 | 0.25 [0.17; 0.36] | 99.26 [98.94; 99.49] | 98.76 [98.22; 99.15] | |
| Rough | 41 | 1395 | 4730 | 48 | 23138.97 | 0.21 [0.16; 0.27] | 99.38 [99.17; 99.53] | 98.96 [98.63; 99.22] | 0.4518 |
(a) Conventional loading vs. immediate loading (category <4 implants excluded). (b) Comparison of immediate loading vs. conventional loading for mandible/fixed and mandible/removable
| Number of study populations | Number of patients | Number of implants | Total number of post‐loading implant losses | Total exposure time (implant years) | Estimated loss rate per 100 implant years [95% CI] | Estimated 3‐year implant survival (%) [95% CI] | Estimated 5‐year implant survival (%) [95% CI] |
| |
|---|---|---|---|---|---|---|---|---|---|
|
| |||||||||
| Overall comparison | |||||||||
| Conventional | 56 | 1773 | 6835 | 99 | 42576.93 | 0.24 [0.19; 0.28] | 99.30 [99.15; 99.43] | 98.66 [98.41; 98.91] | |
| Immediate | 14 | 361 | 1532 | 24 | 5936.87 | 0.40 [0.27; 0.60] | 98.79 [98.21; 99.19] | 97.99 [97.03; 98.65] | 0.0151 |
| Fixed (maxilla and mandible) | |||||||||
| Conventional | 17 | 598 | 3512 | 41 | 24693.90 | 0.17 [0.12; 0.23] | 99.50 [99.33; 99.63] | 98.86 [98.51; 99.10] | |
| Immediate | 9 | 209 | 1143 | 10 | 3691.64 | 0.27 [0.15; 0.50] | 99.19 [98.50; 99.56] | 98.65 [97.51; 99.27] | 0.1652 |
| Removable (maxilla and mandible) | |||||||||
| Conventional | 39 | 1175 | 3323 | 58 | 17883.03 | 0.32 [0.25; 0.42] | 99.03 [98.75; 99.25] | 98.41 [97.92; 98.76] | |
| Immediate | 5 | 152 | 389 | 14 | 2245.23 | 0.62 [0.37; 1.05] | 98.15 [96.89; 98.90] | 96.95 [94.89; 98.17] | 0.0282 |
| Maxilla (fixed and removable) | |||||||||
| Conventional | 14 | 296 | 1847 | 61 | 12566.00 | 0.49 [0.38; 0.62] | 98.55 [98.15; 98.87] | 97.60 [96.93; 98.13] | |
| Immediate | 5 | 127 | 731 | 2 | 2688.18 | 0.08 [0.02; 0.32] | 99.75 [99.04; 99.94] | 99.60 [98.40; 99.90] | 0.0125 |
| Mandible (fixed and removable) | |||||||||
| Conventional | 42 | 1477 | 4988 | 38 | 30010.93 | 0.13 [0.09; 0.17] | 99.62 [99.48; 99.72] | 99.35 [99.15; 99.55] | |
| Immediate | 9 | 234 | 801 | 22 | 3455.69 | 0.64 [0.42; 0.97] | 98.12 [97.14; 98.75] | 96.87 [95.28; 97.93] | <0.0001 |
|
| |||||||||
| Mandible/fixed | |||||||||
| Conventional | 9 | 386 | 1999 | 5 | 13210.00 | 0.04 [0.02; 0.09] | 99.89 [99.73; 99.95] | 99.80 [99.55; 99.90] | |
| Immediate | 4 | 82 | 412 | 4 | 1210.46 | 0.66 [0.33; 1.32] | 98.04 [96.11; 99.01] | 96.75 [93.61; 98.36] | <0.0001 |
| Mandible/removable | |||||||||
| Conventional | 33 | 1091 | 2989 | 33 | 16800.93 | 0.20 [0.14; 0.28] | 99.41 [99.17; 99.58] | 99.01 [98.61; 99.30] | |
| Immediate | 5 | 152 | 389 | 14 | 2245.23 | 0.62 [0.37; 1.05] | 98.14 [96.89; 98.90] | 96.93 [94.87; 98.17] | 0.0003 |
Estimates with corresponding standard errors and P‐values resulting from the multivariate Poisson regression model
| Factor/Interaction | Estimate | Standard Error |
|
|---|---|---|---|
| Intercept | −4.7007 | 0.7327 | <0.0001 |
| Jaw | 0.0108 | 0.7610 | 0.9886 |
| Type of prosthesis | −2.4227 | 0.1921 | <0.0001 |
| Surface of implant | 0.7254 | 0.1913 | 0.0001 |
| Loading protocol | 1.0085 | 0.7427 | 0.1745 |
| Jaw‐loading protocol | −2.6806 | 0.7790 | 0.0006 |
| Conventional vs. immediate (mandible) | −1.6721 | 0.2748 | <0.0001 |
| Conventional vs. immediate (maxilla) | 1.0085 | 0.7427 | 0.1745 |
| Mandible vs. maxilla (conventional) | −2.6698 | 0.2048 | <0.0001 |
| Mandible vs. maxilla (immediate) | −0.9976 | 0.2677 | 0.9886 |