Literature DB >> 21503194

Immediate loading on mandibular edentulous patient with SFI Bar® overdenture.

Ha-Young Kim1, Ryan Jin-Young Kim, Sarah Qadeer, Chang-Mo Jeong, Sang-Wan Shin, Jung-Bo Huh.   

Abstract

Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar® (Cendres et Métaux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

Entities:  

Keywords:  Dental Implant; Immediate Loading; Overdenture; SFI-bar

Year:  2011        PMID: 21503194      PMCID: PMC3076574          DOI: 10.4047/jap.2011.3.1.47

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


  15 in total

1.  A 2-year clinical report of patients treated with two loading protocols for mandibular overdentures: early versus conventional loading.

Authors:  Ilser Turkyilmaz; Tolga F Tözüm; Celal Tumer; Esma Nida Ozbek
Journal:  J Periodontol       Date:  2006-12       Impact factor: 6.993

2.  Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases.

Authors:  M Chiapasco; C Gatti; E Rossi; W Haefliger; T H Markwalder
Journal:  Clin Oral Implants Res       Date:  1997-02       Impact factor: 5.977

3.  Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.

Authors:  P I Brånemark; B O Hansson; R Adell; U Breine; J Lindström; O Hallén; A Ohman
Journal:  Scand J Plast Reconstr Surg Suppl       Date:  1977

Review 4.  Direct bone anchorage of dental implants.

Authors:  T Albrektsson
Journal:  J Prosthet Dent       Date:  1983-08       Impact factor: 3.426

5.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.

Authors:  R Adell; U Lekholm; B Rockler; P I Brånemark
Journal:  Int J Oral Surg       Date:  1981-12

6.  Implant-retained mandibular overdentures with Brånemark System MKII implants: a prospective comparative study between delayed and immediate loading.

Authors:  M Chiapasco; S Abati; E Romeo; G Vogel
Journal:  Int J Oral Maxillofac Implants       Date:  2001 Jul-Aug       Impact factor: 2.804

Review 7.  Immediate and early implant loading protocols: a literature review of clinical studies.

Authors:  Nikolai J Attard; George A Zarb
Journal:  J Prosthet Dent       Date:  2005-09       Impact factor: 3.426

8.  Immediate functional loading of edentulous maxilla: a 5-year retrospective study of 388 titanium implants.

Authors:  Marco Degidi; Adriano Piattelli; Pietro Felice; Francesco Carinci
Journal:  J Periodontol       Date:  2005-06       Impact factor: 6.993

9.  A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: three-year results.

Authors:  Michael I MacEntee; Joanne N Walton; Ned Glick
Journal:  J Prosthet Dent       Date:  2005-01       Impact factor: 3.426

10.  Implant-retained mandibular overdentures with immediate loading: a 3- to 8-year prospective study on 328 implants.

Authors:  Matteo Chiapasco; Claudio Gatti
Journal:  Clin Implant Dent Relat Res       Date:  2003       Impact factor: 3.932

View more
  1 in total

1.  Wear, microleakage and plastic deformation of an implant-supported chair-side bar system.

Authors:  Christian Johannes Mehl; Martin Steiner; Klaus Ludwig; Matthias Kern
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.