Literature DB >> 9586456

Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases.

M Chiapasco1, C Gatti, E Rossi, W Haefliger, T H Markwalder.   

Abstract

A multicenter retrospective study has been conducted on 226 patients necessitating an implant-supported overdenture in the lower jaw. The patients were provided with 904 osseointegrated implants inserted in the interforaminal area of the mental symphisis (4 implants per patient). 4 titanium implant systems were used: TPS and ITI screw implants (Straumann Institute, Waldenburg, Switzerland); Ha-Ti screw implants (Mathys Dental Implants, Bettlach, Switzerland); NLS screw implants (Friatec, Mannheim, Germany). Immediately after implant placement, a U-shaped gold bar was fabricated and implants were immediately loaded with an implant-retained overdenture. Out of 226 patients treated, 194 were followed from a minimum of 2 years to a maximum of 13 years, with a mean follow-up of 6.4 years, whereas 32 patients dropped out during follow-up. The overall failure rate of implants was 3.1% (24/776 implants), whereas the failure rate of bars was 1.5% (3/194 bars). Results from this study showed that the success rate of immediately loaded implants is similar to that obtained in the case of delayed loading, after osseointegration has taken place. In contrast, this method shortens dental rehabilitation times with relevant satisfaction for patients.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9586456     DOI: 10.1111/j.1600-0501.1997.tb00007.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  23 in total

1.  Failure patterns of four osseointegrated oral implant systems.

Authors:  M Esposito; J M Hirsch; U Lekholm; P Thomsen
Journal:  J Mater Sci Mater Med       Date:  1997-12       Impact factor: 3.896

2.  Relation between insertion torque and bone-implant contact percentage: an artificial bone study.

Authors:  Cheng Liu; Ming-Tzu Tsai; Heng-Li Huang; Michael Yuan-Chien Chen; Jui-Ting Hsu; Kuo-Chih Su; Chih-Han Chang; Aaron Yu-Jen Wu
Journal:  Clin Oral Investig       Date:  2012-01-10       Impact factor: 3.573

3.  Delayed versus immediate loading of implants: survival analysis and risk factors for dental implant failure.

Authors:  Srinivas M Susarla; Sung-Kiang Chuang; Thomas B Dodson
Journal:  J Oral Maxillofac Surg       Date:  2008-02       Impact factor: 1.895

4.  Immediate loading of implants in the edentulous mandible: a multicentre study.

Authors:  Paulo Esteves Pinto Faria; Bárbara Masalskas; Anders Heyden; Lars Rasmusson; Luiz Antonio Salata
Journal:  Oral Maxillofac Surg       Date:  2016-09-16

5.  The use of light/chemically hardened polymethylmethacrylate, polyhydroxyethylmethacrylate, and calcium hydroxide graft material in combination with polyanhydride around implants in minipigs: part I: immediate stability and function.

Authors:  Hatice Hasturk; Alpdogan Kantarci; Mazen Ghattas; Marcella Schmidt; Russell A Giordano; Arthur Ashman; Thomas G Diekwisch; Thomas Van Dyke
Journal:  J Periodontol       Date:  2011-02-22       Impact factor: 6.993

6.  A clinico radiographic study of immediate loading implants in rehabilitation of mandibular ridges.

Authors:  M Viswambaran; Vimal Arora; S H Gupta; R K Dhiman; N Thiruvalluvan
Journal:  Med J Armed Forces India       Date:  2014-08-22

7.  Immediate loading on mandibular edentulous patient with SFI Bar® overdenture.

Authors:  Ha-Young Kim; Ryan Jin-Young Kim; Sarah Qadeer; Chang-Mo Jeong; Sang-Wan Shin; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2011-03-31       Impact factor: 1.904

8.  Results of immediate loading for implant restoration in partially edentulous patients: a 6-month preliminary prospective study using SinusQuick™ EB implant system.

Authors:  Jong-Hwa Kim; Young-Kyun Kim; Yang-Jin Yi; Pil-Young Yun; Hyo-Jung Lee; Myung-Jin Kim; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2009-11-30       Impact factor: 1.904

9.  Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study.

Authors:  Mariano Herrero-Climent; Rocio Santos-García; Reyes Jaramillo-Santos; Manuel-Maria Romero-Ruiz; Ana Fernández-Palacin; Pedro Lázaro-Calvo; Pedro Bullón; Jose-Vicente Ríos-Santos
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-11-01

Review 10.  Rehabilitation with implant-supported overdentures in total edentulous patients: A review.

Authors:  Juan F Martínez-Lage-Azorín; Gustavo Segura-Andrés; Joan Faus-López; Rubén Agustín-Panadero
Journal:  J Clin Exp Dent       Date:  2013-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.