Literature DB >> 17209784

A 2-year clinical report of patients treated with two loading protocols for mandibular overdentures: early versus conventional loading.

Ilser Turkyilmaz1, Tolga F Tözüm, Celal Tumer, Esma Nida Ozbek.   

Abstract

BACKGROUND: The original Brånemark protocol for dental implant treatment was based on submerged healing prior to loading. In recent years, immediate/early functional loading has been reported to be possible with high success for various indications including two splinted mandibular implants supporting an overdenture. However, there are a limited number of studies regarding the early loading protocol for two unsplinted mandibular implants supporting an overdenture.
METHODS: A total of 26 edentulous patients were treated with two unsplinted dental implants supporting mandibular overdentures. All implants were placed in the canine regions of each mandible according to the one-stage surgery. For the test group, overdentures were connected 1 week after surgery, and for the control group, overdentures were connected 3 months after surgery. Peri-implant parameters were recorded 1, 6, 12, 18, and 24 months after surgery. Marginal bone levels were evaluated at implant placement and after 6, 12, 18, and 24 months. Clinical stability measurements were performed at surgery, and after 3, 6, 12, 18, and 24 months.
RESULTS: No implant from either group was lost during 2 years. Clinical peri-implant parameters, clinical implant stability measurements, and marginal bone resorptions showed no statistically significant differences between the two groups during 24 months.
CONCLUSION: The results of this clinical trial suggest that the early loading approach of two dental implants supporting a mandibular overdenture does not jeopardize peri-implant soft tissue health, marginal bone resorption, and implant stability.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17209784     DOI: 10.1902/jop.2006.060115

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  5 in total

Review 1.  Immediate loading of overdentures: systematic review.

Authors:  Marcelo Coelho Goiato; Lisiane Cristina Bannwart; Aldiéris Alves Pesqueira; Daniela Micheline dos Santos; Marcela Filié Haddad; Murillo Rezende Santos; Paula Uchoa Castilho
Journal:  Oral Maxillofac Surg       Date:  2013-07-05

Review 2.  Interventions for replacing missing teeth: different times for loading dental implants.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Hassan Maghaireh; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-03-28

3.  Immediate loading on mandibular edentulous patient with SFI Bar® overdenture.

Authors:  Ha-Young Kim; Ryan Jin-Young Kim; Sarah Qadeer; Chang-Mo Jeong; Sang-Wan Shin; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2011-03-31       Impact factor: 1.904

Review 4.  Implant loss and crestal bone loss in early loading versus delayed and immediate loading in edentulous mandibles. A systematic review and meta-analysis.

Authors:  Beatriz Pardal-Peláez; Javier Flores-Fraile; José-Luis Pardal-Refoyo; Javier Montero
Journal:  J Clin Exp Dent       Date:  2021-04-01

5.  Clinical efficacy of early loading versus conventional loading of dental implants.

Authors:  Yanfei Zhu; Xinyi Zheng; Guanqi Zeng; Yi Xu; Xinhua Qu; Min Zhu; Eryi Lu
Journal:  Sci Rep       Date:  2015-11-06       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.