Literature DB >> 21500259

Reduction of implant RF heating through modification of transmit coil electric field.

Yigitcan Eryaman1, Burak Akin, Ergin Atalar.   

Abstract

In this work, we demonstrate the possibility to modify the electric-field distribution of a radio frequency (RF) coil to generate electric field-free zones in the body without significantly altering the transmit sensitivity. Because implant heating is directly related to the electric-field distribution, implant-friendly RF transmit coils can be obtained by this approach. We propose a linear birdcage transmit coil with a zero electric-field plane as an example of such implant-friendly coils. When the zero electric-field plane coincides with the implant position, implant heating is reduced, as we demonstrated by the phantom experiments. By feeding RF pulses with identical phases and shapes but different amplitudes to the two orthogonal ports of the coil, the position of the zero electric-field plane can also be adjusted. Although implant heating is reduced with this method, a linear birdcage coil results in a whole-volume average specific absorption rate that is twice that of a quadrature birdcage coil. To solve this issue, we propose alternative methods to design implant-friendly RF coils with optimized electromagnetic fields and reduced whole-volume average specific absorption rate. With these methods, the transmit field was modified to reduce RF heating of implants and obtain uniform transmit sensitivity.
Copyright © 2010 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2010        PMID: 21500259     DOI: 10.1002/mrm.22724

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Active decoupling of RF coils using a transmit array system.

Authors:  Ali Caglar Özen; Michael Bock; Ergin Atalar
Journal:  MAGMA       Date:  2015-08-05       Impact factor: 2.310

2.  It's the little things: On the complexity of planar electrode heating in MRI.

Authors:  Johannes B Erhardt; Thomas Lottner; Jessica Martinez; Ali C Özen; Martin Schuettler; Thomas Stieglitz; Daniel B Ennis; Michael Bock
Journal:  Neuroimage       Date:  2019-03-29       Impact factor: 6.556

3.  The 'virtual DBS population': five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studies.

Authors:  Bastien Guerin; Maria Ida Iacono; Mathias Davids; Darin Dougherty; Leonardo M Angelone; Lawrence L Wald
Journal:  Phys Med Biol       Date:  2019-02-04       Impact factor: 3.609

4.  Controlling radiofrequency-induced currents in guidewires using parallel transmit.

Authors:  Maryam Etezadi-Amoli; Pascal Stang; Adam Kerr; John Pauly; Greig Scott
Journal:  Magn Reson Med       Date:  2014-12-17       Impact factor: 4.668

5.  Construction and modeling of a reconfigurable MRI coil for lowering SAR in patients with deep brain stimulation implants.

Authors:  Laleh Golestanirad; Maria Ida Iacono; Boris Keil; Leonardo M Angelone; Giorgio Bonmassar; Michael D Fox; Todd Herrington; Elfar Adalsteinsson; Cristen LaPierre; Azma Mareyam; Lawrence L Wald
Journal:  Neuroimage       Date:  2016-12-21       Impact factor: 6.556

6.  Feasibility of using linearly polarized rotating birdcage transmitters and close-fitting receive arrays in MRI to reduce SAR in the vicinity of deep brain simulation implants.

Authors:  Laleh Golestanirad; Boris Keil; Leonardo M Angelone; Giorgio Bonmassar; Azma Mareyam; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2016-04-05       Impact factor: 4.668

7.  Reducing RF-induced Heating near Implanted Leads through High-Dielectric Capacitive Bleeding of Current (CBLOC).

Authors:  Laleh Golestanirad; Leonardo M Angelone; John Kirsch; Sean Downs; Boris Keil; Giorgio Bonmassar; Lawrence L Wald
Journal:  IEEE Trans Microw Theory Tech       Date:  2019-01-01       Impact factor: 3.599

8.  Reconfigurable MRI technology for low-SAR imaging of deep brain stimulation at 3T: Application in bilateral leads, fully-implanted systems, and surgically modified lead trajectories.

Authors:  Ehsan Kazemivalipour; Boris Keil; Alireza Vali; Sunder Rajan; Behzad Elahi; Ergin Atalar; Lawrence L Wald; Joshua Rosenow; Julie Pilitsis; Laleh Golestanirad
Journal:  Neuroimage       Date:  2019-05-13       Impact factor: 6.556

9.  A simple geometric analysis method for measuring and mitigating RF induced currents on Deep Brain Stimulation leads by multichannel transmission/reception.

Authors:  Yigitcan Eryaman; Naoharu Kobayashi; Sean Moen; Joshua Aman; Andrea Grant; J Thomas Vaughan; Gregory Molnar; Michael C Park; Jerrold Vitek; Gregor Adriany; Kamil Ugurbil; Noam Harel
Journal:  Neuroimage       Date:  2018-09-28       Impact factor: 6.556

10.  Parallel transmit pulse design for patients with deep brain stimulation implants.

Authors:  Yigitcan Eryaman; Bastien Guerin; Can Akgun; Joaquin L Herraiz; Adrian Martin; Angel Torrado-Carvajal; Norberto Malpica; Juan A Hernandez-Tamames; Emanuele Schiavi; Elfar Adalsteinsson; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-06-19       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.