Literature DB >> 20139803

C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

Alda L Tam1, Ashraf Mohamed, Marcus Pfister, Ponraj Chinndurai, Esther Rohm, Andrew F Hall, Michael J Wallace.   

Abstract

STUDY
DESIGN: Retrospective review.
OBJECTIVE: To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. SUMMARY OF BACKGROUND DATA: C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty.
METHODS: This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy.
RESULTS: Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1/3 border of the vertebral body was measured, and 75% when distance from target to needle tip was measured. There were no major complications. Minor complications consisted of 3 cases (25%) of cement extravasation.
CONCLUSION: C-arm CBCT with needle path overlay for fluoroscopic guided vertebroplasty is feasible and allows for reliable unilateral therapy of both lumbar and thoracic vertebral bodies. Extrapedicular approaches were performed safely and with good accuracy of reaching the targets.

Entities:  

Mesh:

Year:  2010        PMID: 20139803     DOI: 10.1097/BRS.0b013e3181bc39c6

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  17 in total

1.  Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit.

Authors:  Alessandro Pedicelli; Tommaso Verdolotti; Angelo Pompucci; Flora Desiderio; Francesco D'Argento; Cesare Colosimo; Lorenzo Bonomo
Journal:  Skeletal Radiol       Date:  2011-10-01       Impact factor: 2.199

2.  Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT.

Authors:  Catherine M Phan; Eric A Macklin; Miriam A Bredella; Monica Dadrich; Paul Flechsig; Albert J Yoo; Joshua A Hirsch; Rajiv Gupta
Journal:  Skeletal Radiol       Date:  2010-07-25       Impact factor: 2.199

3.  Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance: a phantom study.

Authors:  Nils Rathmann; Michael Kostrzewa; Kerim Kara; Soenke Bartling; Holger Haubenreisser; Stefan O Schoenberg; Steffen J Diehl
Journal:  Br J Radiol       Date:  2015-09-15       Impact factor: 3.039

4.  Laser-assisted flat-detector CT-guided intracranial access.

Authors:  Daniel L Cooke; Michael R Levitt; Louis J Kim; Danial K Hallam; Laligam N Sekhar; Basavaraj V Ghodke
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-08-05       Impact factor: 2.924

5.  C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis.

Authors:  Simon C Leschka; Drazenko Babic; Samer El Shikh; Christine Wossmann; Martin Schumacher; Christian A Taschner
Journal:  Neuroradiology       Date:  2011-04-08       Impact factor: 2.804

6.  Accuracy of flat panel detector CT with integrated navigational software with and without MR fusion for single-pass needle placement.

Authors:  Marc C Mabray; Sanjit Datta; Prasheel V Lillaney; Teri Moore; Sonja Gehrisch; Jason F Talbott; Michael R Levitt; Basavaraj V Ghodke; Paul S Larson; Daniel L Cooke
Journal:  J Neurointerv Surg       Date:  2015-06-05       Impact factor: 5.836

7.  Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules.

Authors:  Nicola Rotolo; Chiara Floridi; Andrea Imperatori; Federico Fontana; Anna Maria Ierardi; Monica Mangini; Veronica Arlant; Giuseppe De Marchi; Raffaele Novario; Lorenzo Dominioni; Carlo Fugazzola; Gianpaolo Carrafiello
Journal:  Eur Radiol       Date:  2015-06-06       Impact factor: 5.315

8.  Feasibility of laser-guided percutaneous pedicle screw placement in the lumbar spine using a hybrid-OR.

Authors:  P H Richter; F Gebhard; M Salameh; K Schuetze; M Kraus
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-10       Impact factor: 2.924

9.  Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study.

Authors:  Boris Schulz; Katrin Eichler; Petra Siebenhandl; Tatjana Gruber-Rouh; Christoph Czerny; Thomas Josef Vogl; Stephan Zangos
Journal:  Eur Radiol       Date:  2012-07-21       Impact factor: 5.315

10.  Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

Authors:  Jijo Paul; Volkmar Jacobi; Mohammad Farhang; Babak Bazrafshan; Thomas J Vogl; Emmanuel C Mbalisike
Journal:  Eur Radiol       Date:  2012-12-19       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.