Intrasession repeatability of fixation stability assessment with the Nidek MP-1.

Fred K Chen1, Praveen J Patel, Wen Xing, Michael D Crossland, Catey Bunce, Gary S Rubin, Lyndon Da Cruz.   

Abstract

PURPOSE: This study aims to determine the intrasession repeatability and agreement using two methods to analyze fixation stability recorded during microperimetry in patients with macular disease.
METHODS: Fifty patients with macular disease were enrolled prospectively to perform two consecutive microperimetry examinations on the Nidek microperimeter-1 (MP-1) using the same 1° red cross for fixation, Humphrey 10 to 2 grid of 68 test loci, 4 to 2 stair-case strategy, and 200 ms duration stimuli of Goldmann III size. Fixational eye movement was recorded during the two microperimetry examinations, and fixation stability was analyzed in two ways: (1) qualitatively through fixation stability grade (unstable, relatively unstable, and stable) and (2) quantitatively by calculating the logarithm of the bivariate contour ellipse area (logBCEA) that encompassed 68% of fixation points. Agreement and repeatability were assessed by unweighted kappa and the coefficient of repeatability.
RESULTS: The mean (SD) visual acuity (VA) was 0.34 (0.32) logarithm of minimum angle of resolution. The mean (SD) duration of microperimetry was 13 (4) and 12 (4) min during the first and second measurements, respectively. During the first test, 10, 19, and 21 patients had unstable, relatively unstable, and stable fixation stability grading, respectively. Seventy percent (kappa: 0.53) of the fixation stability grading remained unchanged during repeat measurement. Of the remaining, 14% had a one-step decline and 16% had a one-step improvement in stability grading. The mean logBCEA were 4.28 and 4.24 in first and second tests, respectively (p = 0.43). The coefficient of repeatability for logBCEA was 0.61.
CONCLUSIONS: The logBCEA method of analysis for fixation stability assessment is preferable. If logBCEA derived from a microperimetry task is used as part of the core outcome set in a clinical trial, a change of >0.61 may be considered to exceed the limit of test-retest variability.

Entities:  

Mesh:

Year:  2011        PMID: 21460754     DOI: 10.1097/OPX.0b013e3182167641

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  10 in total

1.  Fundus-controlled two-color dark adaptometry with the Microperimeter MP1.

Authors:  Wadim Bowl; Knut Stieger; Birgit Lorenz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-04-24       Impact factor: 3.117

2.  Macular function and morphologic features in juvenile stargardt disease: longitudinal study.

Authors:  Francesco Testa; Paolo Melillo; Valentina Di Iorio; Ada Orrico; Marcella Attanasio; Settimio Rossi; Francesca Simonelli
Journal:  Ophthalmology       Date:  2014-08-02       Impact factor: 12.079

3.  Evaluation of fixation stability using different targets with the MP1 microperimeter.

Authors:  M Cesareo; D Manca; E Ciuffoletti; V De Giovanni; F Ricci; C Nucci; L Cerulli
Journal:  Int Ophthalmol       Date:  2014-04-11       Impact factor: 2.031

4.  Atypical retinotopic organization of visual cortex in patients with central brain damage: congenital and adult onset.

Authors:  Danielle C Reitsma; Jedidiah Mathis; John L Ulmer; Wade Mueller; Mary J Maciejewski; Edgar A DeYoe
Journal:  J Neurosci       Date:  2013-08-07       Impact factor: 6.167

5.  Test-Retest Intervisit Variability of Functional and Structural Parameters in X-Linked Retinoschisis.

Authors:  Brett G Jeffrey; Catherine A Cukras; Susan Vitale; Amy Turriff; Kristin Bowles; Paul A Sieving
Journal:  Transl Vis Sci Technol       Date:  2014-10-03       Impact factor: 3.283

6.  An Audiovisual 3D-Immersive Stimulation Program in Hemianopia Using a Connected Device.

Authors:  Monica Daibert-Nido; Yulia Pyatova; Kyle G Cheung; Arun Reginald; Eduardo Garcia-Giler; Eric Bouffet; Samuel N Markowitz; Michael Reber
Journal:  Am J Case Rep       Date:  2021-06-09

7.  Test-Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease.

Authors:  Stefan Palkovits; Nino Hirnschall; Stefan Georgiev; Christoph Leisser; Oliver Findl
Journal:  Transl Vis Sci Technol       Date:  2018-02-07       Impact factor: 3.283

8.  Intersession test-retest variability of conventional and novel parameters using the MP-1 microperimeter.

Authors:  Evan N Wong; David A Mackey; William H Morgan; Fred Kuanfu Chen
Journal:  Clin Ophthalmol       Date:  2015-12-23

9.  Individual Test Point Fluctuations of Macular Sensitivity in Healthy Eyes and Eyes With Age-Related Macular Degeneration Measured With Microperimetry.

Authors:  Mirella Telles Salgueiro Barboni; Zsuzsanna Szepessy; Dora Fix Ventura; János Németh
Journal:  Transl Vis Sci Technol       Date:  2018-04-23       Impact factor: 3.283

10.  Intersession Test-Retest Variability of Microperimetry in Type 2 Macular Telangiectasia.

Authors:  Evan N Wong; Jehan D A De Soyza; David A Mackey; Ian J Constable; Fred K Chen
Journal:  Transl Vis Sci Technol       Date:  2017-12-12       Impact factor: 3.283

  10 in total