Literature DB >> 21458339

Software compensation of eddy current fields in multislice high order dynamic shimming.

Saikat Sengupta1, Malcolm J Avison, John C Gore, E Brian Welch.   

Abstract

Dynamic B(0) shimming (DS) can produce better field homogeneity than static global shimming by dynamically updating slicewise shim values in a multislice acquisition. The performance of DS however is limited by eddy current fields produced by the switching of 2nd and 3rd order unshielded shims. In this work, we present a novel method of eddy field compensation (EFC) applied to higher order shim induced eddy current fields in multislice DS. This method does not require shim shielding, extra hardware for eddy current compensation or subject specific prescanning. The interactions between shim harmonics are modeled assuming steady state of the medium and long time constant, cross and self term eddy fields in a DS experiment and 'correction factors' characterizing the entire set of shim interactions are derived. The correction factors for a given time between shim switches are shown to be invariable with object scanned, shim switching pattern and actual shim values, allowing for their generalized prospective use. Phantom and human head, 2nd and 3rd order DS experiments performed without any hardware eddy current compensation using the technique show large reductions in field gradients and offsets leading to significant improvements in image quality. This method holds promise as an alternative to expensive hardware based eddy current compensation required in 2nd and 3rd order DS.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21458339      PMCID: PMC3098125          DOI: 10.1016/j.jmr.2011.03.007

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  9 in total

1.  Dynamic shim updating (DSU) for multislice signal acquisition.

Authors:  Robin A de Graaf; Peter B Brown; Scott McIntyre; Douglas L Rothman; Terence W Nixon
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

2.  Computer simulation studies of the effects of dynamic shimming on susceptibility artifacts in EPI at high field.

Authors:  Yansong Zhao; Adam W Anderson; John C Gore
Journal:  J Magn Reson       Date:  2005-03       Impact factor: 2.229

3.  Dynamic shim updating on the human brain.

Authors:  Kevin M Koch; Scott McIntyre; Terence W Nixon; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2006-03-30       Impact factor: 2.229

4.  Real-time shimming to compensate for respiration-induced B0 fluctuations.

Authors:  P van Gelderen; J A de Zwart; P Starewicz; R S Hinks; J H Duyn
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

5.  Dynamic shim updating: a new approach towards optimized whole brain shimming.

Authors:  A M Blamire; D L Rothman; T Nixon
Journal:  Magn Reson Med       Date:  1996-07       Impact factor: 4.668

6.  Dynamic shimming for multi-slice magnetic resonance imaging.

Authors:  G Morrell; D Spielman
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

7.  Reduction of pulsed gradient settling time in the superconducting magnet of a magnetic resonance instrument.

Authors:  D J Jensen; W W Brey; J L Delayre; P A Narayana
Journal:  Med Phys       Date:  1987 Sep-Oct       Impact factor: 4.071

8.  Dynamic Shimming of the Human Brain at 7 Tesla.

Authors:  Christoph Juchem; Terence W Nixon; Piotr Diduch; Douglas L Rothman; Piotr Starewicz; Robin A de Graaf
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2010-07-06       Impact factor: 1.176

9.  Volume parcellation for improved dynamic shimming.

Authors:  Michael Poole; Richard Bowtell
Journal:  MAGMA       Date:  2008-01-08       Impact factor: 2.310

  9 in total
  3 in total

Review 1.  Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.

Authors:  El-Sayed H Ibrahim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

2.  Dynamic B0 shimming for multiband imaging using high order spherical harmonic shims.

Authors:  Hoby P Hetherington; Chan Hong Moon; Michael Schwerter; Nadim Joni Shah; Jullie W Pan
Journal:  Magn Reson Med       Date:  2020-08-28       Impact factor: 4.668

3.  The Travelling-Wave Primate System: A New Solution for Magnetic Resonance Imaging of Macaque Monkeys at 7 Tesla Ultra-High Field.

Authors:  Tim Herrmann; Johannes Mallow; Markus Plaumann; Michael Luchtmann; Jörg Stadler; Judith Mylius; Michael Brosch; Johannes Bernarding
Journal:  PLoS One       Date:  2015-06-11       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.