Literature DB >> 21455542

An isothermal amplification reactor with an integrated isolation membrane for point-of-care detection of infectious diseases.

Changchun Liu1, Eran Geva, Michael Mauk, Xianbo Qiu, William R Abrams, Daniel Malamud, Kelly Curtis, S Michele Owen, Haim H Bau.   

Abstract

A simple, point of care, inexpensive, disposable cassette for the detection of nucleic acids extracted from pathogens was designed, constructed, and tested. The cassette utilizes a single reaction chamber for isothermal amplification of nucleic acids. The chamber is equipped with an integrated, flow-through, Flinders Technology Associates (Whatman FTA®) membrane for the isolation, concentration, and purification of DNA and/or RNA. The nucleic acids captured by the membrane are used directly as templates for amplification without elution, thus simplifying the cassette's flow control. The FTA membrane also serves another critical role-enabling the removal of inhibitors that dramatically reduce detection sensitivity. Thermal control is provided with a thin film heater external to the cassette. The amplification process was monitored in real time with a portable, compact fluorescent reader. The utility of the integrated, single-chamber cassette was demonstrated by detecting the presence of HIV-1 in oral fluids. The HIV RNA was reverse transcribed and subjected to loop-mediated, isothermal amplification (LAMP). A detection limit of less than 10 HIV particles was demonstrated. The cassette is particularly suitable for resource poor regions, where funds and trained personnel are in short supply. The cassette can be readily modified to detect nucleic acids associated with other pathogens borne in saliva, urine, and other body fluids as well as in water and food.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21455542      PMCID: PMC4360993          DOI: 10.1039/c1an00007a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  44 in total

1.  Loop-mediated isothermal amplification of DNA.

Authors:  T Notomi; H Okayama; H Masubuchi; T Yonekawa; K Watanabe; N Amino; T Hase
Journal:  Nucleic Acids Res       Date:  2000-06-15       Impact factor: 16.971

Review 2.  Salivary diagnostics: enhancing disease detection and making medicine better.

Authors:  Alik Segal; David T Wong
Journal:  Eur J Dent Educ       Date:  2008-02       Impact factor: 2.355

3.  Integrated microfluidic tmRNA purification and real-time NASBA device for molecular diagnostics.

Authors:  Ivan K Dimov; Jose L Garcia-Cordero; Justin O'Grady; Claus R Poulsen; Caroline Viguier; Lorcan Kent; Paul Daly; Bryan Lincoln; Majella Maher; Richard O'Kennedy; Terry J Smith; Antonio J Ricco; Luke P Lee
Journal:  Lab Chip       Date:  2008-10-24       Impact factor: 6.799

4.  Microfluidic immunoassays as rapid saliva-based clinical diagnostics.

Authors:  Amy E Herr; Anson V Hatch; Daniel J Throckmorton; Huu M Tran; James S Brennan; William V Giannobile; Anup K Singh
Journal:  Proc Natl Acad Sci U S A       Date:  2007-03-20       Impact factor: 11.205

5.  Multiplex PCR for the simultaneous detection of pseudorabies virus, porcine cytomegalovirus, and porcine circovirus in pigs.

Authors:  Chul-Seung Lee; Hyoung-Joon Moon; Jeong-Sun Yang; Seong-Jun Park; Dae-Sub Song; Bo-Kyu Kang; Bong-Kyun Park
Journal:  J Virol Methods       Date:  2006-10-10       Impact factor: 2.014

6.  Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products.

Authors:  Norihiro Tomita; Yasuyoshi Mori; Hidetoshi Kanda; Tsugunori Notomi
Journal:  Nat Protoc       Date:  2008       Impact factor: 13.491

7.  Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP).

Authors:  Kelly A Curtis; Donna L Rudolph; S Michele Owen
Journal:  J Virol Methods       Date:  2008-06-03       Impact factor: 2.014

8.  Enhancing the performance of a point-of-care CD4+ T-cell counting microchip through monocyte depletion for HIV/AIDS diagnostics.

Authors:  Xuanhong Cheng; Amit Gupta; Chihchen Chen; Ronald G Tompkins; William Rodriguez; Mehmet Toner
Journal:  Lab Chip       Date:  2009-02-04       Impact factor: 6.799

9.  A timer-actuated immunoassay cassette for detecting molecular markers in oral fluids.

Authors:  Changchun Liu; Xianbo Qiu; Serge Ongagna; Dafeng Chen; Zongyuan Chen; William R Abrams; Daniel Malamud; Paul L A M Corstjens; Haim H Bau
Journal:  Lab Chip       Date:  2008-12-05       Impact factor: 6.799

10.  Low-cost HIV-1 diagnosis and quantification in dried blood spots by real time PCR.

Authors:  Nishaki Mehta; Sonia Trzmielina; Bareng A S Nonyane; Melissa N Eliot; Rongheng Lin; Andrea S Foulkes; Kristina McNeal; Arthur Ammann; Vindu Eulalievyolo; John L Sullivan; Katherine Luzuriaga; Mohan Somasundaran
Journal:  PLoS One       Date:  2009-06-05       Impact factor: 3.240

View more
  53 in total

1.  Whole-saliva proteolysis and its impact on salivary diagnostics.

Authors:  K Thomadaki; E J Helmerhorst; N Tian; X Sun; W L Siqueira; D R Walt; F G Oppenheim
Journal:  J Dent Res       Date:  2011-09-13       Impact factor: 6.116

2.  Emerging Loop-Mediated Isothermal Amplification-Based Microchip and Microdevice Technologies for Nucleic Acid Detection.

Authors:  Mohammadali Safavieh; Manoj K Kanakasabapathy; Farhang Tarlan; Minhaz U Ahmed; Mohammed Zourob; Waseem Asghar; Hadi Shafiee
Journal:  ACS Biomater Sci Eng       Date:  2016-01-21

Review 3.  Basic consideration of research strategies for head and neck cancer.

Authors:  Jin Gao; Ben Panizza; Newell W Johnson; Scott Coman; Alan R Clough
Journal:  Front Med       Date:  2012-09-28       Impact factor: 4.592

4.  Smart Cup: A Minimally-Instrumented, Smartphone-Based Point-of-Care Molecular Diagnostic Device.

Authors:  Shih-Chuan Liao; Jing Peng; Michael G Mauk; Sita Awasthi; Jinzhao Song; Harvey Friedman; Haim H Bau; Changchun Liu
Journal:  Sens Actuators B Chem       Date:  2016-06-28       Impact factor: 7.460

5.  Polyethersulfone improves isothermal nucleic acid amplification compared to current paper-based diagnostics.

Authors:  J C Linnes; N M Rodriguez; L Liu; C M Klapperich
Journal:  Biomed Microdevices       Date:  2016-04       Impact factor: 2.838

Review 6.  Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones.

Authors:  Ke Yang; Hagit Peretz-Soroka; Yong Liu; Francis Lin
Journal:  Lab Chip       Date:  2016-02-22       Impact factor: 6.799

Review 7.  Miniaturized devices for point of care molecular detection of HIV.

Authors:  Michael Mauk; Jinzhao Song; Haim H Bau; Robert Gross; Frederic D Bushman; Ronald G Collman; Changchun Liu
Journal:  Lab Chip       Date:  2017-01-31       Impact factor: 6.799

8.  Smartphone-Based Mobile Detection Platform for Molecular Diagnostics and Spatiotemporal Disease Mapping.

Authors:  Jinzhao Song; Vikram Pandian; Michael G Mauk; Haim H Bau; Sara Cherry; Laurence C Tisi; Changchun Liu
Journal:  Anal Chem       Date:  2018-03-22       Impact factor: 6.986

9.  Membrane-based, sedimentation-assisted plasma separator for point-of-care applications.

Authors:  Changchun Liu; Michael Mauk; Robert Gross; Frederic D Bushman; Paul H Edelstein; Ronald G Collman; Haim H Bau
Journal:  Anal Chem       Date:  2013-10-25       Impact factor: 6.986

10.  A high-efficiency superhydrophobic plasma separator.

Authors:  Changchun Liu; Shih-Chuan Liao; Jinzhao Song; Michael G Mauk; Xuanwen Li; Gaoxiang Wu; Dengteng Ge; Robert M Greenberg; Shu Yang; Haim H Bau
Journal:  Lab Chip       Date:  2016-02-07       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.