Literature DB >> 21419595

Pathology of 219 human cadaver eyes with 1-piece or 3-piece hydrophobic acrylic intraocular lenses: capsular bag opacification and sites of square-edged barrier breach.

Peter J Ness1, Liliana Werner, Surekha Maddula, Don Davis, Brian Zaugg, Jack Stringham, Michael Burrow, Oliver Yeh.   

Abstract

PURPOSE: To assess capsular bag opacification and sites of initial posterior capsule opacification (PCO) in human cadaver eyes with square-edged 1-piece or 3-piece hydrophobic acrylic intraocular lenses (IOLs).
SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
DESIGN: Experimental study.
METHODS: Eyes were immersed in 10% formalin after enucleation and had anterior segment scanning with very-high-frequency ultrasound (Artemis). After the eyes were sectioned at the equator, gross examination of the anterior segment was performed from the posterior aspect to assess capsular bag opacification, anterior capsule coverage of the IOL edge, and IOL fixation. Selected eyes had histopathologic examination.
RESULTS: One hundred nineteen eyes with 1-piece IOLs and 100 with 3-piece IOLs were included in the analyses of capsular bag opacification. There was no difference in central (P=.29) or peripheral (P=.76) PCO. In 63 of 84 eyes with a 1-piece IOL and peripheral PCO, the optic-haptic junction was the site of initiation. In eyes with a 3-piece IOL, initial peripheral PCO was observed at nearly the same rate whether there was full 360-degree anterior capsulorhexis overlap of the optic or no overlap (P=.13). In the latter, the site of PCO initiation was in areas lacking capsulorhexis coverage in 46% of eyes.
CONCLUSIONS: There was no difference in central or peripheral PCO between 1-piece and 3-piece hydrophobic acrylic IOLs. With 1-piece IOLs, PCO tended to start at the optic-haptic junctions. With 3-piece IOLs, full anterior capsule coverage did not produce a statistically significant benefit with respect to PCO prevention.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21419595     DOI: 10.1016/j.jcrs.2010.11.036

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  13 in total

1.  Pathologic assessment of complications with asymmetric or sulcus fixation of square-edged hydrophobic acrylic intraocular lenses.

Authors:  Kevin R Kirk; Liliana Werner; Ryan Jaber; Susan Strenk; Lawrence Strenk; Nick Mamalis
Journal:  Ophthalmology       Date:  2012-03-15       Impact factor: 12.079

2.  Pathologic comparison of asymmetric or sulcus fixation of 3-piece intraocular lenses with square versus round anterior optic edges.

Authors:  Andrew Ollerton; Liliana Werner; Susan Strenk; Lawrence Strenk; Lisa Leishman; Zachary Bodnar; Kevin R Kirk; Jennifer Michelson; Nick Mamalis
Journal:  Ophthalmology       Date:  2013-04-16       Impact factor: 12.079

3.  Square-edge intraocular lenses and epithelial lens cell proliferation: implications on posterior capsule opacification in an in vitro model.

Authors:  Rita Mencucci; Eleonora Favuzza; Carlotta Boccalini; Jean-Jacques Gicquel; Laura Raimondi
Journal:  BMC Ophthalmol       Date:  2015-01-19       Impact factor: 2.209

4.  Intraocular lens-edge design and material factors contributing to posterior-capsulotomy rates: comparing Hoya FY60aD, PY60aD, and AcrySof SN60WF.

Authors:  Peter J Morgan-Warren; Jm Alaric Smith
Journal:  Clin Ophthalmol       Date:  2013-08-22

Review 5.  Pediatric cataract.

Authors:  Sudarshan Kumar Khokhar; Ganesh Pillay; Chirakshi Dhull; Esha Agarwal; Manish Mahabir; Pulak Aggarwal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

Review 6.  Innovations in pediatric cataract surgery.

Authors:  Sudarshan Kumar Khokhar; Ganesh Pillay; Esha Agarwal; Manish Mahabir
Journal:  Indian J Ophthalmol       Date:  2017-03       Impact factor: 1.848

Review 7.  Biomaterial Influence on Intraocular Lens Performance: An Overview.

Authors:  Cari Pérez-Vives
Journal:  J Ophthalmol       Date:  2018-03-15       Impact factor: 1.909

8.  Rotation versus non-rotation of intraocular lens for prevention of posterior capsular opacification.

Authors:  Rajesh S Joshi; Shrutika A Chavan
Journal:  Indian J Ophthalmol       Date:  2019-09       Impact factor: 1.848

Review 9.  Surface Modification of Intraocular Lenses.

Authors:  Qi Huang; George Pak-Man Cheng; Kin Chiu; Gui-Qin Wang
Journal:  Chin Med J (Engl)       Date:  2016-01-20       Impact factor: 2.628

10.  A meta-analysis of Nd:YAG capsulotomy rates for two hydrophobic intraocular lens materials.

Authors:  Mark Von Tress; James S Marotta; Stephen S Lane; Ramesh Sarangapani
Journal:  Clin Ophthalmol       Date:  2018-06-22
View more