Pathologic comparison of asymmetric or sulcus fixation of 3-piece intraocular lenses with square versus round anterior optic edges.

Andrew Ollerton1, Liliana Werner, Susan Strenk, Lawrence Strenk, Lisa Leishman, Zachary Bodnar, Kevin R Kirk, Jennifer Michelson, Nick Mamalis.   

Abstract

OBJECTIVE: To evaluate the pathologic findings of 3-piece intraocular lenses (IOLs) with asymmetric or sulcus fixation in pseudophakic cadaver eyes, comparing IOLs with square or round edges on the anterior optic surface.
DESIGN: Comparative case series with pathology. PARTICIPANTS: A total of 661 pseudophakic cadaver eyes, obtained from eye banks within the United States, implanted with different IOLs.
METHODS: Anterior segment scanning of whole eyes with a high-frequency ultrasound system or high-resolution anterior segment magnetic resonance imaging followed by gross examination. Selected eyes were processed for complete histopathologic analysis. MAIN OUTCOME MEASURES: Findings from imaging, gross, and histopathologic evaluation that could be related to out-of-the-bag fixation of the lenses.
RESULTS: Of 661 pseudophakic cadaver eyes obtained, 13 had 3-piece hydrophobic acrylic IOLs with anterior and posterior square optic edges, and 14 had 3-piece lenses with anterior round edges (13 silicone lenses and 1 hydrophobic acrylic lens) without symmetric in-the-bag fixation. These 27 selected eyes were processed for complete histopathologic analysis. Gross findings in both groups were composed of IOL decentration and tilt, pigmentary dispersion within the anterior segment and on the IOL surface, and iris transillumination defects. Histopathology of the 14 eyes with 3-piece IOLs with round anterior optic edges showed mild focal disruption of the iris pigmented layer and loop protrusion/erosion in the ciliary sulcus. Additional changes observed in the 13 eyes with square anterior optic edge IOLs included iris changes, such as vacuolization, disruption and loss of the pigmented epithelial layers, iris thinning and atrophy, synechiae, and pigmentary dispersion within the trabecular meshwork. One eye also exhibited initial signs of optic nerve disc cupping.
CONCLUSIONS: In this series, pathologic findings were more severe in eyes implanted with 3-piece IOLs with square anterior optic edges, suggesting that IOLs with round anterior edges are more suitable for sulcus fixation. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.
Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23597794      PMCID: PMC3718860          DOI: 10.1016/j.ophtha.2013.01.029

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  27 in total

1.  Analysis of elements of interlenticular opacification.

Authors:  Liliana Werner; David J Apple; Suresh K Pandey; Kerry D Solomon; Michael E Snyder; Stephen F Brint; Johnny L Gayton; Joel K Shugar; Rupal H Trivedi; Andrea M Izak
Journal:  Am J Ophthalmol       Date:  2002-03       Impact factor: 5.258

2.  Pigmentary dispersion syndrome.

Authors:  R J Mackool
Journal:  J Cataract Refract Surg       Date:  2001-09       Impact factor: 3.351

3.  Sulcus implantation of a 3-piece, 6.0 mm optic, hydrophobic foldable acrylic intraocular lens in phacoemulsification complicated by posterior capsule rupture.

Authors:  Periklis D Brazitikos; Miltiadis O Balidis; Paris Tranos; Sofia Androudi; Nick T Papadopoulos; Ioannis T Tsinopoulos; Vasilios Karabatakis; Nikolaos T Stangos
Journal:  J Cataract Refract Surg       Date:  2002-09       Impact factor: 3.351

4.  Pigment dispersion and chronic intraocular pressure elevation after sulcus placement of 3-piece acrylic intraocular lens.

Authors:  M Camille Almond; Michael C Wu; Philip P Chen
Journal:  J Cataract Refract Surg       Date:  2009-12       Impact factor: 3.351

5.  Eradication of posterior capsule opacification: documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem.

Authors:  D J Apple; Q Peng; N Visessook; L Werner; S K Pandey; M Escobar-Gomez; J Ram; G U Auffarth
Journal:  Ophthalmology       Date:  2001-03       Impact factor: 12.079

Review 6.  A comparison of ciliary sulcus and capsular bag fixation of posterior chamber intraocular lenses.

Authors:  D J Apple; J J Reidy; J M Googe; N Mamalis; L C Novak; K Loftfield; R J Olson
Journal:  J Am Intraocul Implant Soc       Date:  1985-01

7.  Pigmentary dispersion glaucoma secondary to posterior chamber intra-ocular lenses.

Authors:  J T Woodhams; J C Lester
Journal:  Ann Ophthalmol       Date:  1984-09

8.  Pigmentary glaucoma associated with posterior chamber intraocular lenses.

Authors:  J R Samples; E M Van Buskirk
Journal:  Am J Ophthalmol       Date:  1985-09-15       Impact factor: 5.258

9.  Secondary pigmentary glaucoma associated with piggyback intraocular lens implantation.

Authors:  Shirley H L Chang; Gerald Lim
Journal:  J Cataract Refract Surg       Date:  2004-10       Impact factor: 3.351

10.  The effect of texturing the intraocular lens edge on postoperative glare symptoms: a randomized, prospective, double-masked study.

Authors:  Will R Meacock; David J Spalton; Saarg Khan
Journal:  Arch Ophthalmol       Date:  2002-10
View more
  2 in total

1.  Force of lifelong crystalline lens growth: chronic traumatic mechanical insult to the choroid.

Authors:  Lawrence M Strenk; Suqin Guo; Kenneth Lu; Liliana Werner; Susan A Strenk
Journal:  J Cataract Refract Surg       Date:  2022-03-01       Impact factor: 3.528

2.  Surgical Synechiolysis of Iridocapsular Adhesion and Sulcus Placement of a Rigid Intraocular Lens on an Oversized Residual Capsular Rim.

Authors:  Jiao Lyu; Qi Zhang; Haiying Jin; Tingyi Liang; Jili Chen; Peiquan Zhao
Journal:  J Ophthalmol       Date:  2018-09-12       Impact factor: 1.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.