Literature DB >> 21414063

The interrater reliability of inferior vena cava ultrasound by bedside clinician sonographers in emergency department patients.

J Matthew Fields1, Paul A Lee, Katherine Y Jenq, Dustin G Mark, Nova L Panebianco, Anthony J Dean.   

Abstract

OBJECTIVES: Inferior vena cava ultrasound (IVC-US) is a noninvasive bedside tool to assess intravascular volume status. This study set out to investigate the interrater reliability of IVC-US by bedside clinician sonographers and determine whether alternative methods of IVC-US such as B-mode and visual estimation are equally reliable to traditional M-mode.
METHODS: A convenience sample of adult emergency department (ED) patients was prospectively enrolled. Each patient underwent IVC-US by two different emergency physicians (EPs), each of whom first performed visual estimation of IVC percent collapse and of volume status, followed by caliper measurements in M-mode and B-mode. EPs were blinded to patient data and to the other sonographer's results. For each technique, interrater reliability was determined between the two EPs' assessments using intraclass correlation coefficients (ICC) for continuous data and Cohen's weighted kappa for categorical data. In addition, analysis was performed on M-mode diameter measurements to determine the relationship between sonographer and patient characteristics on interrater reliability.
RESULTS: Five EPs performed 92 US exams on 46 patients. Using M-mode, the ICC for maximum IVC diameter was 0.81 (95% confidence interval [CI]=0.67 to 0.89), and for minimum diameter was 0.77 (95% CI=0.62 to 0.87). There were no statistically significant differences between the caliper methods used for IVC measurements (M-mode diameter, B-mode diameter, or B-mode area). Agreement for visually estimated IVC collapse (0.60, 95% CI=0.36 to 0.76) was similar to agreement for calculated M-mode IVC collapse index (0.52, 95% CI=0.27 to 0.71). Cohen's weighted kappa for volume status based on visual estimation of IVC filling (size, shape, and collapse) was 0.64 (95% CI=0.53 to 0.73). ICC values for M-mode diameter measurements were significantly higher in studies involving patients who were noneuvolemic and studies in which sonographers had each performed at least five prior IVC-US.
CONCLUSIONS: Emergency physicians' US measurements of IVC diameter have a high degree of interrater reliability. IVC percent collapse by visual estimation or based on caliper measurements have lower, but still moderate to good reliability. The use of the visual estimation technique should be considered by clinicians who have learned to obtain measured parameters of IVC filling because it is equally reliable to traditional M-mode and can be performed more rapidly.
© 2010 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Year:  2011        PMID: 21414063     DOI: 10.1111/j.1553-2712.2010.00952.x

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  34 in total

1.  Echocardiographic Inferior Vena Cava Measurement As An Alternative to Central Venous Pressure Measurement in Neonates.

Authors:  Muzamil Mustafa Mugloo; Seema Malik; Rubeena Akhtar
Journal:  Indian J Pediatr       Date:  2017-06-21       Impact factor: 1.967

2.  Ultrasound imaging method for internal jugular vein measurement and estimation of circulating blood volume.

Authors:  Kun Qian; Takehiro Ando; Kensuke Nakamura; Hongen Liao; Etsuko Kobayashi; Naoki Yahagi; Ichiro Sakuma
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-18       Impact factor: 2.924

Review 3.  Portable ultrasound in disaster triage: a focused review.

Authors:  S M Wydo; M J Seamon; S W Melanson; P Thomas; D P Bahner; S P Stawicki
Journal:  Eur J Trauma Emerg Surg       Date:  2015-02-11       Impact factor: 3.693

Review 4.  Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Authors:  Jennifer R Marin; Alyssa M Abo; Alexander C Arroyo; Stephanie J Doniger; Jason W Fischer; Rachel Rempell; Brandi Gary; James F Holmes; David O Kessler; Samuel H F Lam; Marla C Levine; Jason A Levy; Alice Murray; Lorraine Ng; Vicki E Noble; Daniela Ramirez-Schrempp; David C Riley; Turandot Saul; Vaishali Shah; Adam B Sivitz; Ee Tein Tay; David Teng; Lindsey Chaudoin; James W Tsung; Rebecca L Vieira; Yaffa M Vitberg; Resa E Lewiss
Journal:  Crit Ultrasound J       Date:  2016-11-03

Review 5.  [Point-of-care ultrasonography of the abdomen in emergency and intensive care medicine].

Authors:  M Milkau; T Noll; F Sayk
Journal:  Med Klin Intensivmed Notfmed       Date:  2018-10-09       Impact factor: 0.840

6.  Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volume.

Authors:  Kensuke Nakamura; Makoto Tomida; Takehiro Ando; Kon Sen; Ryota Inokuchi; Etsuko Kobayashi; Susumu Nakajima; Ichiro Sakuma; Naoki Yahagi
Journal:  J Med Ultrason (2001)       Date:  2013-02-27       Impact factor: 1.314

7.  Surgeon-performed bedside ultrasound to assess volume status: a feasibility study.

Authors:  Deidre L Wyrick; Samuel D Smith; Jeffrey M Burford; Christopher J Swearingen; Melvin S Dassinger
Journal:  Pediatr Surg Int       Date:  2015-10-03       Impact factor: 1.827

8.  The learning curve of sonographic inferior vena cava evaluation by novice medical students: the Pavia experience.

Authors:  Santi Di Pietro; Francesco Falaschi; Alice Bruno; Tiziano Perrone; Valeria Musella; Stefano Perlini
Journal:  J Ultrasound       Date:  2018-03-21

9.  Limited value of end-expiratory inferior vena cava diameter to predict fluid responsiveness impact of intra-abdominal pressure.

Authors:  Antoine Vieillard-Baron; Bruno Evrard; Xavier Repessé; Julien Maizel; Christophe Jacob; Marine Goudelin; Cyril Charron; Gwenaël Prat; Michel Slama; Guillaume Geri; Philippe Vignon
Journal:  Intensive Care Med       Date:  2018-01-22       Impact factor: 17.440

10.  Reproducibility of point-of-care ultrasonography for central vein diameter measurement: Separating image acquisition from interpretation.

Authors:  Brian P Lucas; Antonietta D'Addio; Jennifer Clark; Clay Block; Harold Manning; Brian Remillard; J C Leiter
Journal:  J Clin Ultrasound       Date:  2017-05-08       Impact factor: 0.910

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.