Literature DB >> 28634780

Echocardiographic Inferior Vena Cava Measurement As An Alternative to Central Venous Pressure Measurement in Neonates.

Muzamil Mustafa Mugloo1, Seema Malik2, Rubeena Akhtar3.   

Abstract

OBJECTIVES: To evaluate the correlation between echocardiographic inferior vena cava (IVC) measurements and central venous pressure (CVP) in neonates. Also, to evaluate the correlation between IVC measurements and gestational age (GA) and body weight (BW).
METHODS: This cross sectional analytical study was conducted from June 2014 through June 2016 in a level III NICU. All neonates requiring intensive hemodynamic monitoring and having umbilical venous catheter (UVC) in place for clinical indications were enrolled in the study. IVC measurements were recorded by echocardiography (ECHO) and CVP was measured concomitantly in neonates having appropriate sized UVC in place. IVC measurements were evaluated and compared for any correlation with the CVP, GA and BW.
RESULTS: Fifty neonates with median gestation of 37 wk [Q1 = 29.2, Q3 = 37.8, interquartile range (IQR) = 8.6 wk] and median birth weight of 2420 g (Q1 = 923.5, Q3 = 2850, IQR = 1926.5 g) were included in the study. A strong negative linear correlation was observed between IVC collapsibility index (IVC-CI) and CVP (r = -0.968, r2 = -0.937, p 0.000). No correlation was observed between IVC-CI and GA or BW. IVC minimum and IVC maximum diameters did not correlate with CVP but correlated well with GA and BW.
CONCLUSIONS: Echocardiographic IVC-CI measurement has a good correlation with CVP measurement in neonates. The clinical use will depend on the ability of IVC-CI to predict surrogate markers of tissue perfusion in shock.

Entities:  

Keywords:  Central venous pressure; Inferior vena cava; Neonates

Mesh:

Year:  2017        PMID: 28634780     DOI: 10.1007/s12098-017-2382-5

Source DB:  PubMed          Journal:  Indian J Pediatr        ISSN: 0019-5456            Impact factor:   1.967


  18 in total

1.  Use of hand-carried ultrasound devices to augment the accuracy of medical student bedside cardiac diagnoses.

Authors:  Jeanne M Decara; James N Kirkpatrick; Kirk T Spencer; R Parker Ward; Kristen Kasza; Kathleen Furlong; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2005-03       Impact factor: 5.251

2.  Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology.

Authors:  Roberto M Lang; Michelle Bierig; Richard B Devereux; Frank A Flachskampf; Elyse Foster; Patricia A Pellikka; Michael H Picard; Mary J Roman; James Seward; Jack S Shanewise; Scott D Solomon; Kirk T Spencer; Martin St John Sutton; William J Stewart
Journal:  J Am Soc Echocardiogr       Date:  2005-12       Impact factor: 5.251

3.  Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava.

Authors:  B J Kircher; R B Himelman; N B Schiller
Journal:  Am J Cardiol       Date:  1990-08-15       Impact factor: 2.778

4.  Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis.

Authors:  Joerg C Schefold; Christian Storm; Sven Bercker; Rene Pschowski; Michael Oppert; Anne Krüger; Dietrich Hasper
Journal:  J Emerg Med       Date:  2008-04-01       Impact factor: 1.484

5.  Ultrasonographic evaluation of ventilatory effect on inferior vena caval configuration.

Authors:  H Natori; S Tamaki; S Kira
Journal:  Am Rev Respir Dis       Date:  1979-08

6.  The interrater reliability of inferior vena cava ultrasound by bedside clinician sonographers in emergency department patients.

Authors:  J Matthew Fields; Paul A Lee; Katherine Y Jenq; Dustin G Mark; Nova L Panebianco; Anthony J Dean
Journal:  Acad Emerg Med       Date:  2011-01       Impact factor: 3.451

7.  Inferior vena cava diameter: a useful method for estimation of fluid status in children on haemodialysis.

Authors:  I Krause; E Birk; M Davidovits; R Cleper; L Blieden; L Pinhas; Z Gamzo; B Eisenstein
Journal:  Nephrol Dial Transplant       Date:  2001-06       Impact factor: 5.992

8.  The rate at which residents learn to use hand-held echocardiography at the bedside.

Authors:  David B Hellmann; Quinn Whiting-O'Keefe; Edward P Shapiro; L David Martin; Carol Martire; Roy C Ziegelstein
Journal:  Am J Med       Date:  2005-09       Impact factor: 4.965

9.  Inferior vena cava diameter and collapsibility index: a practical non-invasive evaluation of intravascular fluid volume in critically-ill patients.

Authors:  Prasert Thanakitcharu; Marisa Charoenwut; Napha Siriwiwatanakul
Journal:  J Med Assoc Thai       Date:  2013-03

10.  Prospective evaluation of intravascular volume status in critically ill patients: does inferior vena cava collapsibility correlate with central venous pressure?

Authors:  Stanislaw P A Stawicki; Eric J Adkins; Daniel S Eiferman; David C Evans; Naeem A Ali; Chinedu Njoku; David E Lindsey; Charles H Cook; Jayaraj M Balakrishnan; Sebastian Valiaveedan; Sagar C Galwankar; Creagh T Boulger; Andrew N Springer; David P Bahner
Journal:  J Trauma Acute Care Surg       Date:  2014-04       Impact factor: 3.313

View more
  6 in total

1.  Can Inferior Vena Cava Measurement be an Alternative to Central Venous Pressure Measurement?

Authors:  Arpita Chattopadhyay; Rakesh Lodha
Journal:  Indian J Pediatr       Date:  2017-09-08       Impact factor: 1.967

Review 2.  A new stethoscope for pediatric intensivists: Point-of-care ultrasound.

Authors:  Dinçer Yıldızdaş; Nagehan Aslan
Journal:  Turk Pediatri Ars       Date:  2020-12-16

3.  Ultrasonographic inferior vena cava collapsibility and distensibility indices for detecting the volume status of critically ill pediatric patients.

Authors:  Dincer Yildizdas; Nagehan Aslan
Journal:  J Ultrason       Date:  2020-09-28

4.  Gas embolism under standard versus low pneumoperitoneum pressure during laparoscopic liver resection (GASES): study protocol for a randomized controlled trial.

Authors:  Danfeng Jin; Mingyue Liu; Jian Huang; Yongfeng Xu; Luping Liu; Changhong Miao; Jing Zhong
Journal:  Trials       Date:  2021-11-15       Impact factor: 2.279

5.  Predictive Value of the Respiratory Variation in Inferior Vena Cava Diameter for Ventilated Children With Septic Shock.

Authors:  Zihong Xiong; Guoying Zhang; Qin Zhou; Bing Lu; Xuemei Zheng; Mengjun Wu; Yi Qu
Journal:  Front Pediatr       Date:  2022-07-07       Impact factor: 3.569

6.  Plethysmography variability index (PVI) changes in preterm neonates with shock-an observational study.

Authors:  Dinesh Pawale; Srinivas Murki; Dattatray Kulkarni; Venkateshwarlu Vardhelli; Deepak Sharma; Tejopratap Oleti; Sai Kiran; Venkat Kallem; Tanveer Bashir
Journal:  Eur J Pediatr       Date:  2020-08-12       Impact factor: 3.183

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.